EMDN A02: Syringes

Complete hierarchy for EMDN group A02 in category A (Devices for Administration, Withdrawal and Collection): 32 terminal codes, EMDN v2026. Terminal codes are the ones accepted in a EUDAMED device record.

Registered classes, as of 8 Sep 2026. For each code with at least 20 registrations under a legislation, the chip shows how devices registered in EUDAMED under that code are classed, counted once per primary UDI-DI and kept separate for each legislation. It is not a determination. The class of a device comes from the MDR and IVDR classification rules for its intended purpose. MDD and IVDD classes are the directive classification and can differ from the class the same device would have under MDR or IVDR.

  • A02Syringes
    • A0201Single-Use Syringes
      • A020101Loss-of-Resistance SyringesMDR 2 classes · n=89terminal

        Registered in EUDAMED under MDR with this code, the 89 devices are split across classes (as of 8 Sep 2026).

        • 53 Class IIa (59.5%)
        • 36 Class I (40.4%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • A020102Infusion and Irrigation Syringes, Single-Use
        • A02010201Infusion and Irrigation Syringes, Luer Cone, Single-Use
          • A0201020101Infusion and Irrigation Syringes, 2-Piece Luer Cone, Single-Use
            • A020102010101Infusion and Irrigation Syringes, 2-Piece Luer Cone, 2-Piece with Needle, Single-UseMDR 100.0% Class IIa · n=386MDD 100.0% Class IIa · n=31terminal

              Registered in EUDAMED under MDR with this code: 386 of 386 devices carry Class IIa on their registration (as of 8 Sep 2026).

              • 386 Class IIa (100.0%)

              Registered in EUDAMED under MDD with this code: 31 of 31 devices carry Class IIa on their registration (as of 8 Sep 2026).

              • 31 Class IIa (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • A020102010102Infusion and Irrigation Syringes, 2-Piece Luer Cone, 2-Piece without Needle, Single-UseMDR 2 classes · n=381MDD 2 classes · n=71terminal

              Registered in EUDAMED under MDR with this code, the 381 devices are split across classes (as of 8 Sep 2026).

              • 204 Class IIa (53.5%)
              • 177 Class I (46.4%)

              Registered in EUDAMED under MDD with this code, the 71 devices are split across classes (as of 8 Sep 2026).

              • 45 Class I (63.3%)
              • 26 Class IIa (36.6%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • A0201020102Infusion and Irrigation Syringes, Luer Cone, 3-Piece
            • A020102010201Infusion and Irrigation Syringes, Luer Cone, 3-Piece with Needle, Single-UseMDR 99.9% Class IIa · n=1,586MDD 100.0% Class IIa · n=233terminal

              Registered in EUDAMED under MDR with this code: 1,585 of 1,586 devices carry Class IIa on their registration (as of 8 Sep 2026).

              • 1,585 Class IIa (99.9%)
              • 1 Class I (<0.1%)

              Registered in EUDAMED under MDD with this code: 233 of 233 devices carry Class IIa on their registration (as of 8 Sep 2026).

              • 233 Class IIa (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • A020102010202Infusion and Irrigation Syringes, Luer Cone, 3-Piece without Needle, Single-UseMDR 2 classes · n=469MDD 2 classes · n=169terminal

              Registered in EUDAMED under MDR with this code, the 469 devices are split across classes (as of 8 Sep 2026).

              • 364 Class I (77.6%)
              • 105 Class IIa (22.3%)

              Registered in EUDAMED under MDD with this code, the 169 devices are split across classes (as of 8 Sep 2026).

              • 85 Class IIa (50.2%)
              • 84 Class I (49.7%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • A02010202Infusion and Irrigation Syringes, Luer Lock Cone, Single-Use
          • A0201020201Infusion and Irrigation Syringes, Luer Lock Cone, 3-Piece, Single-Use
            • A020102020101Infusion and Irrigation Syringes, Luer Lock Cone, 3-Piece with Needle, Single-UseMDR 99.6% Class IIa · n=1,072MDD 99.6% Class IIa · n=311terminal

              Registered in EUDAMED under MDR with this code: 1,068 of 1,072 devices carry Class IIa on their registration (as of 8 Sep 2026).

              • 1,068 Class IIa (99.6%)
              • 4 Class I (0.3%)

              Registered in EUDAMED under MDD with this code: 310 of 311 devices carry Class IIa on their registration (as of 8 Sep 2026).

              • 310 Class IIa (99.6%)
              • 1 Class III (0.3%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • A020102020102Infusion and Irrigation Syringes, Luer Lock Cone, 3-Piece without Needle, Single-UseMDR 2 classes · n=608MDD 2 classes · n=429terminal

              Registered in EUDAMED under MDR with this code, the 608 devices are split across classes (as of 8 Sep 2026).

              • 366 Class I (60.1%)
              • 242 Class IIa (39.8%)

              Registered in EUDAMED under MDD with this code, the 429 devices are split across classes (as of 8 Sep 2026).

              • 281 Class I (65.5%)
              • 148 Class IIa (34.4%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • A02010203Infusion and Irrigation Syringes, Catheter Cone, Single-UseMDR 96.8% Class I · n=94MDD 95.8% Class I · n=48terminal

          Registered in EUDAMED under MDR with this code: 91 of 94 devices carry Class I on their registration (as of 8 Sep 2026).

          • 91 Class I (96.8%)
          • 3 Class IIa (3.1%)

          Registered in EUDAMED under MDD with this code: 46 of 48 devices carry Class I on their registration (as of 8 Sep 2026).

          • 46 Class I (95.8%)
          • 2 Class IIa (4.1%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • A02010204Infusion and Irrigation Syringes, without Cone, with Fixed Needle, Single-UseMDR 100.0% Class IIa · n=65terminal

          Registered in EUDAMED under MDR with this code: 65 of 65 devices carry Class IIa on their registration (as of 8 Sep 2026).

          • 65 Class IIa (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • A02010205Infusion and Irrigation Syringes with Safety System, Single-UseMDR 96.3% Class IIa · n=407MDD 100.0% Class IIa · n=55terminal

          Registered in EUDAMED under MDR with this code: 392 of 407 devices carry Class IIa on their registration (as of 8 Sep 2026).

          • 392 Class IIa (96.3%)
          • 15 Class I (3.6%)

          Registered in EUDAMED under MDD with this code: 55 of 55 devices carry Class IIa on their registration (as of 8 Sep 2026).

          • 55 Class IIa (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • A02010299Infusion and Irrigation Syringes - OtherMDR 2 classes · n=337MDD 3 classes · n=95terminal

          Registered in EUDAMED under MDR with this code, the 337 devices are split across classes (as of 8 Sep 2026).

          • 248 Class IIa (73.5%)
          • 89 Class I (26.4%)

          Registered in EUDAMED under MDD with this code, the 95 devices are split across classes (as of 8 Sep 2026).

          • 73 Class III (76.8%)
          • 11 Class I (11.5%)
          • 11 Class IIa (11.5%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • A020104Syringes for Injectors, Single-Use
        • A02010401Syringes for Contrast Media Injector, Single-UseMDR 99.0% Class IIa · n=823MDD 3 classes · n=401terminal

          Registered in EUDAMED under MDR with this code: 815 of 823 devices carry Class IIa on their registration (as of 8 Sep 2026).

          • 815 Class IIa (99.0%)
          • 8 Class I (0.9%)

          Registered in EUDAMED under MDD with this code, the 401 devices are split across classes (as of 8 Sep 2026).

          • 322 Class IIa (80.2%)
          • 78 Class I (19.4%)
          • 1 Class IIb (0.2%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • A02010499Syringes for Injector, Single-Use - OtherMDR 2 classes · n=583MDD 2 classes · n=52terminal

          Registered in EUDAMED under MDR with this code, the 583 devices are split across classes (as of 8 Sep 2026).

          • 502 Class IIa (86.1%)
          • 81 Class I (13.8%)

          Registered in EUDAMED under MDD with this code, the 52 devices are split across classes (as of 8 Sep 2026).

          • 32 Class IIa (61.5%)
          • 20 Class I (38.4%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • A020105Blood Gas Analysis, Syringes with Needles and Kits
        • A02010501Blood Gas Analysis, Syringes with Needle W/O Safety System and KitsMDR 100.0% Class IIa · n=44terminal

          Registered in EUDAMED under MDR with this code: 44 of 44 devices carry Class IIa on their registration (as of 8 Sep 2026).

          • 44 Class IIa (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • A02010502Blood Gas Analysis, Syringes with Safety Needle and KitsMDR 99.1% Class IIa · n=119terminal

          Registered in EUDAMED under MDR with this code: 118 of 119 devices carry Class IIa on their registration (as of 8 Sep 2026).

          • 118 Class IIa (99.1%)
          • 1 Class I (0.8%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • A020106Insulin Syringes, Single-Use
        • A02010601Insulin Syringes with Fixed Needle, Single-UseMDR 100.0% Class IIa · n=510MDD 100.0% Class IIa · n=32terminal

          Registered in EUDAMED under MDR with this code: 510 of 510 devices carry Class IIa on their registration (as of 8 Sep 2026).

          • 510 Class IIa (100.0%)

          Registered in EUDAMED under MDD with this code: 32 of 32 devices carry Class IIa on their registration (as of 8 Sep 2026).

          • 32 Class IIa (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • A02010602Insulin Syringes W/O Fixed Needles, Single-UseMDR 2 classes · n=150MDD 97.8% Class IIa · n=91terminal

          Registered in EUDAMED under MDR with this code, the 150 devices are split across classes (as of 8 Sep 2026).

          • 112 Class I (74.6%)
          • 38 Class IIa (25.3%)

          Registered in EUDAMED under MDD with this code: 89 of 91 devices carry Class IIa on their registration (as of 8 Sep 2026).

          • 89 Class IIa (97.8%)
          • 2 Class I (2.1%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • A02010603Insulin Syringes with Safety System, Single-Use
          • A0201060301Insulin Syringes with Safety Systems and Fixed Needles, Single-UseMDR 100.0% Class IIa · n=38terminal

            Registered in EUDAMED under MDR with this code: 38 of 38 devices carry Class IIa on their registration (as of 8 Sep 2026).

            • 38 Class IIa (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

          • A0201060302Insulin Syringes with Safety Systems W/O Fixed Needle, Single-Useterminal
        • A02010699Insulin Syringes, Single-Use - OtherMDR 2 classes · n=45terminal

          Registered in EUDAMED under MDR with this code, the 45 devices are split across classes (as of 8 Sep 2026).

          • 39 Class IIa (86.6%)
          • 6 Class I (13.3%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • A020107Prefilled Syringes
        • A02010701Prefilled Syringes with Sterile Physiological SolutionMDR 4 classes · n=166MDD 97.3% Class IIa · n=38terminal

          Registered in EUDAMED under MDR with this code, the 166 devices are split across classes (as of 8 Sep 2026).

          • 124 Class IIa (74.6%)
          • 34 Class IIb (20.4%)
          • 7 Class I (4.2%)
          • 1 Class III (0.6%)

          Registered in EUDAMED under MDD with this code: 37 of 38 devices carry Class IIa on their registration (as of 8 Sep 2026).

          • 37 Class IIa (97.3%)
          • 1 Class IIb (2.6%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • A02010702Prefilled Syringes with Sterile Waterterminal
        • A02010799Prefilled Syringes - OtherMDR 3 classes · n=40MDD 4 classes · n=42terminal

          Registered in EUDAMED under MDR with this code, the 40 devices are split across classes (as of 8 Sep 2026).

          • 21 Class I (52.5%)
          • 18 Class III (45.0%)
          • 1 Class IIb (2.5%)

          Registered in EUDAMED under MDD with this code, the 42 devices are split across classes (as of 8 Sep 2026).

          • 25 Class III (59.5%)
          • 9 Class IIa (21.4%)
          • 5 Class IIb (11.9%)
          • 3 Class I (7.1%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • A020108Enteral Feeding SyringesMDR 2 classes · n=446MDD 2 classes · n=243terminal

        Registered in EUDAMED under MDR with this code, the 446 devices are split across classes (as of 8 Sep 2026).

        • 253 Class I (56.7%)
        • 193 Class IIa (43.2%)

        Registered in EUDAMED under MDD with this code, the 243 devices are split across classes (as of 8 Sep 2026).

        • 219 Class I (90.1%)
        • 24 Class IIa (9.8%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • A020109Tuberculin Syringes, Single-UseMDR 2 classes · n=68terminal

        Registered in EUDAMED under MDR with this code, the 68 devices are split across classes (as of 8 Sep 2026).

        • 63 Class IIa (92.6%)
        • 5 Class I (7.3%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • A020199Syringes, Single-Use - OtherMDR 2 classes · n=898MDD 4 classes · n=457terminal

        Registered in EUDAMED under MDR with this code, the 898 devices are split across classes (as of 8 Sep 2026).

        • 624 Class IIa (69.4%)
        • 274 Class I (30.5%)

        Registered in EUDAMED under MDD with this code, the 457 devices are split across classes (as of 8 Sep 2026).

        • 306 Class IIa (66.9%)
        • 147 Class I (32.1%)
        • 2 Class IIb (0.4%)
        • 2 Class III (0.4%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

    • A0202Reusable Syringes
      • A020201Reusable Infusion Syringesterminal
      • A020202Reusable Irrigation SyringesMDR 100.0% Class I · n=115terminal

        Registered in EUDAMED under MDR with this code: 115 of 115 devices carry Class I on their registration (as of 8 Sep 2026).

        • 115 Class I (100.0%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • A020203Cartridge SyringesMDR 3 classes · n=307terminal

        Registered in EUDAMED under MDR with this code, the 307 devices are split across classes (as of 8 Sep 2026).

        • 257 Class I (83.7%)
        • 41 Class IIb (13.3%)
        • 9 Class IIa (2.9%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • A020299Reusable Syringes - OtherMDR 95.6% Class I · n=555MDD 3 classes · n=54terminal

        Registered in EUDAMED under MDR with this code: 531 of 555 devices carry Class I on their registration (as of 8 Sep 2026).

        • 531 Class I (95.6%)
        • 24 Class IIa (4.3%)

        Registered in EUDAMED under MDD with this code, the 54 devices are split across classes (as of 8 Sep 2026).

        • 27 Class IIa (50.0%)
        • 21 Class I (38.8%)
        • 6 Class IIb (11.1%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

    • A0280Syringes - AccessoriesMDR 2 classes · n=166terminal

      Registered in EUDAMED under MDR with this code, the 166 devices are split across classes (as of 8 Sep 2026).

      • 157 Class I (94.5%)
      • 9 Class IIa (5.4%)

      Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

    • A0299Syringes - OtherMDR 2 classes · n=242terminal

      Registered in EUDAMED under MDR with this code, the 242 devices are split across classes (as of 8 Sep 2026).

      • 191 Class IIa (78.9%)
      • 51 Class I (21.0%)

      Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

How A02 is structured

32
terminal codes, selectable in a device record
13
branch headings, not selectable
24
name a specific device type
25%
fallback entries: Other and Accessories

The Syringes branch runs 5 levels deep. 13 entries below are branch headings that group other codes rather than naming a device, so a classification has to resolve all the way down to one of the 32 codes marked terminal.

7 terminal codes are “- Other” entries and 1 is an “- Accessories” entry, 25% of the branch. An “- Other” code is the residual slot for devices its siblings do not name, so it is worth ruling out every specific sibling before settling on one.

The largest sub-branch is A0201 (Single-Use Syringes), holding 26 of the 32 terminal codes.

Frequently asked questions

Which A02 codes can be used in a EUDAMED device record?
32 of the 45 codes listed under A02 (Syringes) are terminal and can be selected. The other 13 are branch headings that cannot.
How deep is the A02 hierarchy?
The A02 branch runs 5 levels below the group code. Its largest sub-branch is A0201 (Single-Use Syringes), which holds 26 of the 32 terminal codes.
How many A02 codes are catch-all entries?
7 terminal codes under A02 are "- Other" entries and 1 is an "- Accessories" entry, 25% of the branch. The remaining 24 name a specific device type.

Not sure which level to stop at, or which of two plausible codes to submit? The guide to choosing an EMDN code walks the decision level by level, with a worked example and the mistakes that get a EUDAMED registration rejected.

Classifying more than a handful of devices?

EUDAMate maps your device list against all 6,773 terminal EMDN codes with confidence-scored suggestions you review and confirm. Start with a free Readiness Check on your own data.

Run a free Readiness Check

Other groups in category A

Source: European Commission, EMDN v2026 official release. Terminal codes are the only codes accepted in a EUDAMED device record. EMDN is a nomenclature, not a risk classification. MDR/IVDR class is determined separately.