EMDN L01: Sharp Instruments, Reusable

Complete hierarchy for EMDN group L01 in category L (Reusable Surgical Instruments): 60 terminal codes, EMDN v2026. Terminal codes are the ones accepted in a EUDAMED device record.

Registered classes, as of 8 Sep 2026. For each code with at least 20 registrations under a legislation, the chip shows how devices registered in EUDAMED under that code are classed, counted once per primary UDI-DI and kept separate for each legislation. It is not a determination. The class of a device comes from the MDR and IVDR classification rules for its intended purpose. MDD and IVDD classes are the directive classification and can differ from the class the same device would have under MDR or IVDR.

  • L01Sharp Instruments, Reusable
    • L0103Dermotomes and Blades, ReusableMDR 100.0% Class I · n=62MDD 2 classes · n=31terminal

      Registered in EUDAMED under MDR with this code: 62 of 62 devices carry Class I on their registration (as of 8 Sep 2026).

      • 62 Class I (100.0%)

      Registered in EUDAMED under MDD with this code, the 31 devices are split across classes (as of 8 Sep 2026).

      • 20 Class I (64.5%)
      • 11 Class IIa (35.4%)

      Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

    • L0104Surgical Scissors, Reusable
      • L010401Scissors for Bandages and Clothing, Reusable
        • L01040101Scissors for Plasters, ReusableMDR 100.0% Class I · n=176terminal

          Registered in EUDAMED under MDR with this code: 176 of 176 devices carry Class I on their registration (as of 8 Sep 2026).

          • 176 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01040102Scissors for Bandages, ReusableMDR 99.7% Class I · n=400MDD 2 classes · n=50terminal

          Registered in EUDAMED under MDR with this code: 399 of 400 devices carry Class I on their registration (as of 8 Sep 2026).

          • 399 Class I (99.7%)
          • 1 Class IIa (0.2%)

          Registered in EUDAMED under MDD with this code, the 50 devices are split across classes (as of 8 Sep 2026).

          • 45 Class I (90.0%)
          • 5 Class IIa (10.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • L01040103Scissors for Clothing, Reusableterminal
        • L01040199Scissors for Bandages and Clothing, Reusable - OtherMDR 99.8% Class I · n=1,078terminal

          Registered in EUDAMED under MDR with this code: 1,076 of 1,078 devices carry Class I on their registration (as of 8 Sep 2026).

          • 1,076 Class I (99.8%)
          • 2 Class IIa (0.1%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • L010402Surgical Sutures Scissors, Reusable
        • L01040201Staple Remover Scissors, ReusableMDR 97.7% Class I · n=45terminal

          Registered in EUDAMED under MDR with this code: 44 of 45 devices carry Class I on their registration (as of 8 Sep 2026).

          • 44 Class I (97.7%)
          • 1 Class IIa (2.2%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01040202Ligatures Scissors, ReusableMDR 100.0% Class I · n=85terminal

          Registered in EUDAMED under MDR with this code: 85 of 85 devices carry Class I on their registration (as of 8 Sep 2026).

          • 85 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01040299Surgical Sutures Scissors, Reusable - OtherMDR 99.4% Class I · n=189terminal

          Registered in EUDAMED under MDR with this code: 188 of 189 devices carry Class I on their registration (as of 8 Sep 2026).

          • 188 Class I (99.4%)
          • 1 Class IIa (0.5%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • L010403Surgical Dissection Scissors, ReusableMDR 99.9% Class I · n=2,868MDD 97.9% Class I · n=1,541terminal

        Registered in EUDAMED under MDR with this code: 2,866 of 2,868 devices carry Class I on their registration (as of 8 Sep 2026).

        • 2,866 Class I (99.9%)
        • 2 Class IIa (<0.1%)

        Registered in EUDAMED under MDD with this code: 1,510 of 1,541 devices carry Class I on their registration (as of 8 Sep 2026).

        • 1,510 Class I (97.9%)
        • 31 Class IIa (2.0%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • L010404Cardiovascular Surgery Scissors, Reusable
        • L01040401Cardiac Scissors, Reusableterminal
        • L01040402Vascular Scissors, ReusableMDR 100.0% Class I · n=452MDD 100.0% Class I · n=696terminal

          Registered in EUDAMED under MDR with this code: 452 of 452 devices carry Class I on their registration (as of 8 Sep 2026).

          • 452 Class I (100.0%)

          Registered in EUDAMED under MDD with this code: 696 of 696 devices carry Class I on their registration (as of 8 Sep 2026).

          • 696 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • L010405Ophthalmology Scissors, Reusable
        • L01040501Corneal Scissors, ReusableMDR 100.0% Class I · n=242MDD 100.0% Class I · n=61terminal

          Registered in EUDAMED under MDR with this code: 242 of 242 devices carry Class I on their registration (as of 8 Sep 2026).

          • 242 Class I (100.0%)

          Registered in EUDAMED under MDD with this code: 61 of 61 devices carry Class I on their registration (as of 8 Sep 2026).

          • 61 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • L01040502Ocular Enucleation Scissors, ReusableMDR 100.0% Class I · n=117terminal

          Registered in EUDAMED under MDR with this code: 117 of 117 devices carry Class I on their registration (as of 8 Sep 2026).

          • 117 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01040503Iris Scissors, ReusableMDR 100.0% Class I · n=826MDD 2 classes · n=71terminal

          Registered in EUDAMED under MDR with this code: 826 of 826 devices carry Class I on their registration (as of 8 Sep 2026).

          • 826 Class I (100.0%)

          Registered in EUDAMED under MDD with this code, the 71 devices are split across classes (as of 8 Sep 2026).

          • 66 Class I (92.9%)
          • 5 Class IIa (7.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • L01040504Vitreo-Retina Surgery Scissors, ReusableMDR 100.0% Class I · n=63terminal

          Registered in EUDAMED under MDR with this code: 63 of 63 devices carry Class I on their registration (as of 8 Sep 2026).

          • 63 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01040505Conjunctiva Scissors, Reusableterminal
        • L01040506Tenotomy and Strabism Correction Scissors, ReusableMDR 100.0% Class I · n=163MDD 100.0% Class I · n=23terminal

          Registered in EUDAMED under MDR with this code: 163 of 163 devices carry Class I on their registration (as of 8 Sep 2026).

          • 163 Class I (100.0%)

          Registered in EUDAMED under MDD with this code: 23 of 23 devices carry Class I on their registration (as of 8 Sep 2026).

          • 23 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • L01040507Blepharoplasty Scissors, Reusableterminal
        • L01040508Endocular Implants Scissors, Reusableterminal
        • L01040509Ocular Adnexa Scissors, Reusable
          • L0104050901Ciliary Scissors, Reusableterminal
          • L0104050999Ocular Adnexa Scissors, Reusable - Otherterminal
        • L01040510Capsulotomy Scissors, ReusableMDR 100.0% Class I · n=42terminal

          Registered in EUDAMED under MDR with this code: 42 of 42 devices carry Class I on their registration (as of 8 Sep 2026).

          • 42 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01040599Ophthalmology Scissors, Reusable - OtherMDR 100.0% Class I · n=271terminal

          Registered in EUDAMED under MDR with this code: 271 of 271 devices carry Class I on their registration (as of 8 Sep 2026).

          • 271 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • L010406Otolaryngological (ENT) Surgery Scissors, Reusable
        • L01040601Nasal Scissors, ReusableMDR 100.0% Class I · n=161terminal

          Registered in EUDAMED under MDR with this code: 161 of 161 devices carry Class I on their registration (as of 8 Sep 2026).

          • 161 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01040602Ear Surgery Scissors, ReusableMDR 100.0% Class I · n=77terminal

          Registered in EUDAMED under MDR with this code: 77 of 77 devices carry Class I on their registration (as of 8 Sep 2026).

          • 77 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01040603Tonsillar Scissors, ReusableMDR 100.0% Class I · n=91MDD 100.0% Class I · n=45terminal

          Registered in EUDAMED under MDR with this code: 91 of 91 devices carry Class I on their registration (as of 8 Sep 2026).

          • 91 Class I (100.0%)

          Registered in EUDAMED under MDD with this code: 45 of 45 devices carry Class I on their registration (as of 8 Sep 2026).

          • 45 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • L01040604Laryngeal Scissors, ReusableMDR 100.0% Class I · n=21terminal

          Registered in EUDAMED under MDR with this code: 21 of 21 devices carry Class I on their registration (as of 8 Sep 2026).

          • 21 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01040699Otolaryngological (ENT) Surgery Scissors, Reusable - OtherMDR 100.0% Class I · n=49terminal

          Registered in EUDAMED under MDR with this code: 49 of 49 devices carry Class I on their registration (as of 8 Sep 2026).

          • 49 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • L010407Neurosurgery Scissors, Reusable
        • L01040701Dura Mater Scissors, ReusableMDR 100.0% Class I · n=42terminal

          Registered in EUDAMED under MDR with this code: 42 of 42 devices carry Class I on their registration (as of 8 Sep 2026).

          • 42 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01040702Nerves Scissors, Reusableterminal
        • L01040799Neurosurgery Scissors, Reusable - OtherMDR 99.4% Class I · n=1,126terminal

          Registered in EUDAMED under MDR with this code: 1,120 of 1,126 devices carry Class I on their registration (as of 8 Sep 2026).

          • 1,120 Class I (99.4%)
          • 6 Class III (0.5%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • L010408Gastroenterology Scissors, Reusable
        • L01040801Intestinal Scissors, Reusable
          • L0104080101Rectal Scissors, ReusableMDR 100.0% Class I · n=39terminal

            Registered in EUDAMED under MDR with this code: 39 of 39 devices carry Class I on their registration (as of 8 Sep 2026).

            • 39 Class I (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

          • L0104080102Enterotomy Scissors, Reusableterminal
          • L0104080199Intestinal Scissors, Reusable - Otherterminal
        • L01040899Gastroenterology Scissors, Reusable - Otherterminal
      • L010409Thoracic Surgery Scissors, ReusableMDR 100.0% Class I · n=86terminal

        Registered in EUDAMED under MDR with this code: 86 of 86 devices carry Class I on their registration (as of 8 Sep 2026).

        • 86 Class I (100.0%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • L010410Odontostomatology Scissors, Reusable
        • L01041001Gingival Scissors, ReusableMDR 100.0% Class I · n=142terminal

          Registered in EUDAMED under MDR with this code: 142 of 142 devices carry Class I on their registration (as of 8 Sep 2026).

          • 142 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01041099Odontostomatology Scissors, Reusable - OtherMDR 100.0% Class I · n=154terminal

          Registered in EUDAMED under MDR with this code: 154 of 154 devices carry Class I on their registration (as of 8 Sep 2026).

          • 154 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • L010411Obstetric-Gynecological Surgery Scissors, Reusable
        • L01041101Obstetrics Scissors, Reusable
          • L0104110101Umbilical Scissors, ReusableMDR 100.0% Class I · n=26terminal

            Registered in EUDAMED under MDR with this code: 26 of 26 devices carry Class I on their registration (as of 8 Sep 2026).

            • 26 Class I (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

          • L0104110102Episiotomy Scissors, ReusableMDR 100.0% Class I · n=41terminal

            Registered in EUDAMED under MDR with this code: 41 of 41 devices carry Class I on their registration (as of 8 Sep 2026).

            • 41 Class I (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

          • L0104110103Cephalotomy Scissors, Reusableterminal
          • L0104110199Obstetrics Scissors, Reusable - Otherterminal
        • L01041102Gynecology Scissors, Reusable
          • L0104110201Uterine Scissors, ReusableMDR 100.0% Class I · n=51terminal

            Registered in EUDAMED under MDR with this code: 51 of 51 devices carry Class I on their registration (as of 8 Sep 2026).

            • 51 Class I (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

          • L0104110202Parametrium Scissors, Reusableterminal
          • L0104110299Gynecology Scissors, Reusable - OtherMDR 100.0% Class I · n=144terminal

            Registered in EUDAMED under MDR with this code: 144 of 144 devices carry Class I on their registration (as of 8 Sep 2026).

            • 144 Class I (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01041199Obstetric-Gynecological Surgery Scissors, Reusable - OtherMDR 100.0% Class I · n=100terminal

          Registered in EUDAMED under MDR with this code: 100 of 100 devices carry Class I on their registration (as of 8 Sep 2026).

          • 100 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • L010412Orthopaedic Surgery Scissors, Reusable
        • L01041201Bone Scissors, ReusableMDR 100.0% Class I · n=39terminal

          Registered in EUDAMED under MDR with this code: 39 of 39 devices carry Class I on their registration (as of 8 Sep 2026).

          • 39 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01041202Wires and Metal Plates Scissors, ReusableMDR 100.0% Class I · n=300terminal

          Registered in EUDAMED under MDR with this code: 300 of 300 devices carry Class I on their registration (as of 8 Sep 2026).

          • 300 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • L01041299Orthopaedic Surgery Scissors, Reusable - OtherMDR 100.0% Class I · n=478MDD 100.0% Class I · n=59terminal

          Registered in EUDAMED under MDR with this code: 478 of 478 devices carry Class I on their registration (as of 8 Sep 2026).

          • 478 Class I (100.0%)

          Registered in EUDAMED under MDD with this code: 59 of 59 devices carry Class I on their registration (as of 8 Sep 2026).

          • 59 Class I (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • L010413Microsurgery Scissors, ReusableMDR 100.0% Class I · n=385MDD 100.0% Class I · n=65terminal

        Registered in EUDAMED under MDR with this code: 385 of 385 devices carry Class I on their registration (as of 8 Sep 2026).

        • 385 Class I (100.0%)

        Registered in EUDAMED under MDD with this code: 65 of 65 devices carry Class I on their registration (as of 8 Sep 2026).

        • 65 Class I (100.0%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • L010499Surgical Scissors, Reusable - OtherMDR 99.9% Class I · n=5,285MDD 97.6% Class I · n=991terminal

        Registered in EUDAMED under MDR with this code: 5,281 of 5,285 devices carry Class I on their registration (as of 8 Sep 2026).

        • 5,281 Class I (99.9%)
        • 4 Class IIa (<0.1%)

        Registered in EUDAMED under MDD with this code: 968 of 991 devices carry Class I on their registration (as of 8 Sep 2026).

        • 968 Class I (97.6%)
        • 23 Class IIa (2.3%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

    • L0101Surgical Scalpels, Reusable
      • L010101Monoblock Surgical Scalpels, ReusableMDR 100.0% Class I · n=333MDD 100.0% Class I · n=31terminal

        Registered in EUDAMED under MDR with this code: 333 of 333 devices carry Class I on their registration (as of 8 Sep 2026).

        • 333 Class I (100.0%)

        Registered in EUDAMED under MDD with this code: 31 of 31 devices carry Class I on their registration (as of 8 Sep 2026).

        • 31 Class I (100.0%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • L010102Scalpel Blades, ReusableMDR 100.0% Class I · n=196MDD 100.0% Class I · n=68terminal

        Registered in EUDAMED under MDR with this code: 196 of 196 devices carry Class I on their registration (as of 8 Sep 2026).

        • 196 Class I (100.0%)

        Registered in EUDAMED under MDD with this code: 68 of 68 devices carry Class I on their registration (as of 8 Sep 2026).

        • 68 Class I (100.0%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • L010103Handles for Scalpels, ReusableMDR 100.0% Class I · n=959MDD 97.4% Class I · n=158terminal

        Registered in EUDAMED under MDR with this code: 959 of 959 devices carry Class I on their registration (as of 8 Sep 2026).

        • 959 Class I (100.0%)

        Registered in EUDAMED under MDD with this code: 154 of 158 devices carry Class I on their registration (as of 8 Sep 2026).

        • 154 Class I (97.4%)
        • 4 Class IIa (2.5%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

    • L0102Surgical Knives, ReusableMDR 99.9% Class I · n=2,738MDD 100.0% Class I · n=112terminal

      Registered in EUDAMED under MDR with this code: 2,737 of 2,738 devices carry Class I on their registration (as of 8 Sep 2026).

      • 2,737 Class I (99.9%)
      • 1 Class IIa (<0.1%)

      Registered in EUDAMED under MDD with this code: 112 of 112 devices carry Class I on their registration (as of 8 Sep 2026).

      • 112 Class I (100.0%)

      Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

    • L0107Surgical Saws and Blades, Reusable
      • L010701Manual Surgical Saws, ReusableMDR 100.0% Class I · n=416MDD 100.0% Class I · n=25terminal

        Registered in EUDAMED under MDR with this code: 416 of 416 devices carry Class I on their registration (as of 8 Sep 2026).

        • 416 Class I (100.0%)

        Registered in EUDAMED under MDD with this code: 25 of 25 devices carry Class I on their registration (as of 8 Sep 2026).

        • 25 Class I (100.0%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • L010702Blades for Manual Surgical Saws, ReusableMDR 100.0% Class I · n=31terminal

        Registered in EUDAMED under MDR with this code: 31 of 31 devices carry Class I on their registration (as of 8 Sep 2026).

        • 31 Class I (100.0%)

        Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

      • L010703Blades for Motorised Surgical Saws, Reusableterminal
    • L0180Sharp Instruments, Reusable - AccessoriesMDR 2 classes · n=30terminal

      Registered in EUDAMED under MDR with this code, the 30 devices are split across classes (as of 8 Sep 2026).

      • 21 Class I (70.0%)
      • 9 Class IIa (30.0%)

      Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

    • L0199Sharp Instruments, Reusable - OtherMDR 2 classes · n=211MDD 99.5% Class I · n=227terminal

      Registered in EUDAMED under MDR with this code, the 211 devices are split across classes (as of 8 Sep 2026).

      • 138 Class I (65.4%)
      • 73 Class IIa (34.5%)

      Registered in EUDAMED under MDD with this code: 226 of 227 devices carry Class I on their registration (as of 8 Sep 2026).

      • 226 Class I (99.5%)
      • 1 Class IIa (0.4%)

      Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

How L01 is structured

60
terminal codes, selectable in a device record
17
branch headings, not selectable
44
name a specific device type
27%
fallback entries: Other and Accessories

The Sharp Instruments, Reusable branch runs 4 levels deep. 17 entries below are branch headings that group other codes rather than naming a device, so a classification has to resolve all the way down to one of the 60 codes marked terminal.

15 terminal codes are “- Other” entries and 1 is an “- Accessories” entry, 27% of the branch. An “- Other” code is the residual slot for devices its siblings do not name, so it is worth ruling out every specific sibling before settling on one.

The largest sub-branch is L0104 (Surgical Scissors, Reusable), holding 50 of the 60 terminal codes.

Frequently asked questions

Which L01 codes can be used in a EUDAMED device record?
60 of the 77 codes listed under L01 (Sharp Instruments, Reusable) are terminal and can be selected. The other 17 are branch headings that cannot.
How deep is the L01 hierarchy?
The L01 branch runs 4 levels below the group code. Its largest sub-branch is L0104 (Surgical Scissors, Reusable), which holds 50 of the 60 terminal codes.
How many L01 codes are catch-all entries?
15 terminal codes under L01 are "- Other" entries and 1 is an "- Accessories" entry, 27% of the branch. The remaining 44 name a specific device type.

Not sure which level to stop at, or which of two plausible codes to submit? The guide to choosing an EMDN code walks the decision level by level, with a worked example and the mistakes that get a EUDAMED registration rejected.

Classifying more than a handful of devices?

EUDAMate maps your device list against all 6,773 terminal EMDN codes with confidence-scored suggestions you review and confirm. Start with a free Readiness Check on your own data.

Run a free Readiness Check

Other groups in category L

Source: European Commission, EMDN v2026 official release. Terminal codes are the only codes accepted in a EUDAMED device record. EMDN is a nomenclature, not a risk classification. MDR/IVDR class is determined separately.