EMDN P07: Vascular and Cardiac Prostheses

Complete hierarchy for EMDN group P07 in category P (Implantable Prosthetic and Osteosynthesis Devices): 97 terminal codes, EMDN v2026. Terminal codes are the ones accepted in a EUDAMED device record.

Registered classes, as of 8 Sep 2026. For each code with at least 20 registrations under a legislation, the chip shows how devices registered in EUDAMED under that code are classed, counted once per primary UDI-DI and kept separate for each legislation. It is not a determination. The class of a device comes from the MDR and IVDR classification rules for its intended purpose. MDD and IVDD classes are the directive classification and can differ from the class the same device would have under MDR or IVDR.

  • P07Vascular and Cardiac Prostheses
    • P0701Vascular Prostheses
      • P070101Biological Vascular Prostheses
        • P07010101Pericardium Vascular Prostheses
          • P0701010101Pericardium Vascular Prostheses, Straightterminal
          • P0701010102Pericardium Vascular Prostheses, Bifurcatedterminal
        • P07010102Homologous Vascular Prostheses,
          • P0701010201Homologous Vascular Prostheses, Straightterminal
          • P0701010202Homologous Vascular Prostheses, Bifurcatedterminal
        • P07010199Biological Vascular Prostheses - Otherterminal
      • P070102Vascular Prostheses, Synthetic
        • P07010201Dacron Vascular Prostheses
          • P0701020101Dacron Vascular Prostheses, Straight
            • P070102010101Dacron Vascular Prostheses, Straight, KnittedMDR 100.0% Class III · n=195MDD 100.0% Class III · n=137terminal

              Registered in EUDAMED under MDR with this code: 195 of 195 devices carry Class III on their registration (as of 8 Sep 2026).

              • 195 Class III (100.0%)

              Registered in EUDAMED under MDD with this code: 137 of 137 devices carry Class III on their registration (as of 8 Sep 2026).

              • 137 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070102010102Dacron Vascular Prostheses, Straight, WovenMDD 100.0% Class III · n=273terminal

              Registered in EUDAMED under MDD with this code: 273 of 273 devices carry Class III on their registration (as of 8 Sep 2026).

              • 273 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0701020102Dacron Vascular Prostheses, Multifurcated
            • P070102010201Dacron Vascular Prostheses, Multifurcated (Aortic Arch (Also Collateral and Multiple) and Thoracic-Abdominal)MDR 100.0% Class III · n=33MDD 100.0% Class III · n=88terminal

              Registered in EUDAMED under MDR with this code: 33 of 33 devices carry Class III on their registration (as of 8 Sep 2026).

              • 33 Class III (100.0%)

              Registered in EUDAMED under MDD with this code: 88 of 88 devices carry Class III on their registration (as of 8 Sep 2026).

              • 88 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070102010202Dacron Vascular Prostheses, Woven, MultifurcatedMDD 100.0% Class III · n=424terminal

              Registered in EUDAMED under MDD with this code: 424 of 424 devices carry Class III on their registration (as of 8 Sep 2026).

              • 424 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • P07010202Ptfe Vascular Prostheses
          • P0701020201Ptfe Vascular Prostheses, Straight
            • P070102020101Ptfe Vascular Prostheses, Straight, SimpleMDR 2 classes · n=97MDD 100.0% Class III · n=42terminal

              Registered in EUDAMED under MDR with this code, the 97 devices are split across classes (as of 8 Sep 2026).

              • 51 Class IIb (52.5%)
              • 46 Class III (47.4%)

              Registered in EUDAMED under MDD with this code: 42 of 42 devices carry Class III on their registration (as of 8 Sep 2026).

              • 42 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070102020102Ptfe Vascular Prostheses, Straight, ReinforcedMDR 100.0% Class III · n=34terminal

              Registered in EUDAMED under MDR with this code: 34 of 34 devices carry Class III on their registration (as of 8 Sep 2026).

              • 34 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

          • P0701020202Ptfe Vascular Prostheses, Bifurcated
            • P070102020201Ptfe Vascular Prostheses, Bifurcated, Simpleterminal
            • P070102020202Ptfe Vascular Prostheses, Bifurcated, Reinforcedterminal
        • P07010299Vascular Prostheses, Synthetic - Otherterminal
      • P070180Vascular Prostheses - Accessoriesterminal
    • P0702Vascular Patches
      • P070201Biological Vascular Patches
        • P07020101Pericardium Vascular Patchesterminal
        • P07020102Sis (Small Intestinal Submucosa) Vascular Patchesterminal
        • P07020199Biological Vascular Patches - Otherterminal
      • P070202Synthetic Vascular Patches
        • P07020201Dacron Vascular PatchesMDD 100.0% Class III · n=71terminal

          Registered in EUDAMED under MDD with this code: 71 of 71 devices carry Class III on their registration (as of 8 Sep 2026).

          • 71 Class III (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • P07020202Ptfe Vascular PatchesMDD 100.0% Class III · n=26terminal

          Registered in EUDAMED under MDD with this code: 26 of 26 devices carry Class III on their registration (as of 8 Sep 2026).

          • 26 Class III (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • P07020203PET Vascular Patchesterminal
        • P07020204Pu Vascular Patchesterminal
        • P07020299Synthetic Vascular Patches - Otherterminal
    • P0703Cardiac Valves
      • P070301Biological Cardiac Valves
        • P07030101Biological Cardiac Valves for Surgical Implant with Support
          • P0703010101Stented Biological Heart Valves for Surgical Implant - Valve Tissue of Animal Origin
            • P070301010101Stented Aortic Biological Valves for Surgical Implant - Valve Tissue of Animal Originterminal
            • P070301010102Stented Mitral Biological Valves for Surgical Implant - Valve Tissue of Animal Originterminal
            • P070301010103Stented Pulmonary Biological Valves for Surgical Implant - Valve Tissue of Animal Originterminal
            • P070301010104Stented Tricuspid Biological Valves for Surgical Implant - Valve Tissue of Animal Originterminal
          • P0703010102Stented Biological Heart Valves for Surgical Implant - Non-Valve Tissue of Animal Origin
            • P070301010201Stented Aortic Biological Valves for Surgical Implant - Non-Valve Tissue of Animal OriginMDR 100.0% Class III · n=34terminal

              Registered in EUDAMED under MDR with this code: 34 of 34 devices carry Class III on their registration (as of 8 Sep 2026).

              • 34 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

            • P070301010202Stented Mitral Biological Valves for Surgical Implant - Non-Valve Tissue of Animal OriginMDR 100.0% Class III · n=24terminal

              Registered in EUDAMED under MDR with this code: 24 of 24 devices carry Class III on their registration (as of 8 Sep 2026).

              • 24 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

            • P070301010203Stented Pulmonary Biological Valves for Surgical Implant - Non-Valve Tissue of Animal Originterminal
            • P070301010204Stented Tricuspid Biological Valves for Surgical Implant - Non-Valve Tissue of Animal Originterminal
        • P07030102Stentless Biological Heart Valves for Surgical Implant
          • P0703010201Stentless Biological Heart Valves for Surgical Implant - Valve Tissue of Animal Originterminal
          • P0703010202Stentless Biological Heart Valves for Surgical Implant - Tissue of Animal Originterminal
        • P07030103Biological Heart Valves for Percutaneous Implantation, with Support
          • P0703010301Stented Biological Heart Valves for Percutaneous Implant - Valve Tissue of Animal Origin
            • P070301030101Stented Biological Aortic Valves for Percutaneous Implant - Valve Tissue of Animal Originterminal
            • P070301030102Stented Biological Mitral Valves for Percutaneous Implant - Valve Tissue of Animal Originterminal
            • P070301030103Stented Biological Pulmonary Valves for Percutaneous Implant - Valve Tissue of Animal Originterminal
            • P070301030104Stented Biological Tricuspid Valves for Percutaneous Implant - Valve Tissue of Animal Originterminal
          • P0703010302Biological Heart Valves with Support for Percutaneous Implant - Non-Valve Tissue of Animal Origin
            • P070301030201Stented Biological Aortic Valves for Percutaneous Implant - Non-Valve Tissue of Animal OriginMDD 100.0% Class III · n=134terminal

              Registered in EUDAMED under MDD with this code: 134 of 134 devices carry Class III on their registration (as of 8 Sep 2026).

              • 134 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070301030202Stented Biological Mitral Valves for Percutaneous Implant - Non-Valve Tissue of Animal Originterminal
            • P070301030203Stented Biological Pulmonary Valves for Percutaneous Implant - Non-Valve Tissue of Animal Originterminal
            • P070301030204Stented Biological Tricuspid Valves for Percutaneous Implant - Non-Valve Tissue of Animal Originterminal
        • P07030104Biological Valves, Bicavalterminal
        • P07030199Biological Heart Valves - Otherterminal
      • P070302Mechanical Heart Valves
        • P07030201Mechanical Heart Valves, Ball-Valvesterminal
        • P07030202Mechanical Heart Valves, Single-DiscMDD 100.0% Class III · n=27terminal

          Registered in EUDAMED under MDD with this code: 27 of 27 devices carry Class III on their registration (as of 8 Sep 2026).

          • 27 Class III (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • P07030203Mechanical Heart Valves Double-Disc
          • P0703020301Bileaflet Mechanical Aortic Valvesterminal
          • P0703020302Bileaflet Mechanical Mitral Valvesterminal
          • P0703020399Bileaflet Mechanical Heart Valves - Otherterminal
        • P07030299Mechanical Heart Valves - Otherterminal
      • P070303Heart Valve Tubes
        • P07030301Biological Heart Valve Tubesterminal
        • P07030302Mechanical Heart Valve Tubesterminal
        • P07030399Heart Valve Tubes - Otherterminal
      • P070304Heart Valve Rings
        • P07030401Flexible or Unsupported Heart Valve RingsMDR 100.0% Class III · n=21terminal

          Registered in EUDAMED under MDR with this code: 21 of 21 devices carry Class III on their registration (as of 8 Sep 2026).

          • 21 Class III (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

        • P07030402Rigid or Semi-Rigid Heart Valve Rings with Supportterminal
        • P07030403Incomplete Semi-Rigid Heart Valve Ringsterminal
        • P07030499Heart Valve Rings - Otherterminal
      • P070380Heart Valves - Accessories
        • P07038001Heart Valve Implant Sizersterminal
        • P07038002Cardiac Valve Transcatheter Implant AccessoriesMDR 2 classes · n=35MDD 96.0% Class III · n=101terminal

          Registered in EUDAMED under MDR with this code, the 35 devices are split across classes (as of 8 Sep 2026).

          • 19 Class III (54.2%)
          • 16 Class I (45.7%)

          Registered in EUDAMED under MDD with this code: 97 of 101 devices carry Class III on their registration (as of 8 Sep 2026).

          • 97 Class III (96.0%)
          • 4 Class I (3.9%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • P07038003Mechanical Heart Valve Implant Accessoriesterminal
        • P07038004Heart Valve Reconstruction Implantsterminal
        • P07038099Heart Valve Accessories - Otherterminal
      • P070399Cardiac Valves - Otherterminal
    • P0704Vascular and Cardiac Endoprostheses
      • P070401Vascular Endoprostheses
        • P07040101Dacron Vascular Endoprostheses
          • P0704010101Dacron Vascular Endoprostheses, Straight
            • P070401010101Dacron Vascular Endoprostheses, Straight - Abdominalterminal
            • P070401010102Dacron Vascular Endoprostheses, Straight - ThoracicMDD 100.0% Class III · n=438terminal

              Registered in EUDAMED under MDD with this code: 438 of 438 devices carry Class III on their registration (as of 8 Sep 2026).

              • 438 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070401010199Dacron Vascular Endoprostheses, Straight - OtherMDD 100.0% Class III · n=115terminal

              Registered in EUDAMED under MDD with this code: 115 of 115 devices carry Class III on their registration (as of 8 Sep 2026).

              • 115 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0704010102Dacron Vascular Endoprostheses, BifurcatedMDD 100.0% Class III · n=76terminal

            Registered in EUDAMED under MDD with this code: 76 of 76 devices carry Class III on their registration (as of 8 Sep 2026).

            • 76 Class III (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0704010103Dacron Vascular Endoprostheses, Auxiliaryterminal
        • P07040102Ptfe Vascular Endoprostheses
          • P0704010201Ptfe Vascular Endoprostheses, Straight
            • P070401020101Ptfe Vascular Endoprostheses, Straight - AbdominalMDD 100.0% Class III · n=111terminal

              Registered in EUDAMED under MDD with this code: 111 of 111 devices carry Class III on their registration (as of 8 Sep 2026).

              • 111 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070401020102Ptfe Vascular Endoprostheses, Straight - ThoracicMDD 100.0% Class III · n=277terminal

              Registered in EUDAMED under MDD with this code: 277 of 277 devices carry Class III on their registration (as of 8 Sep 2026).

              • 277 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070401020103Ptfe Vascular Endoprostheses, Straight - PeripheralMDR 100.0% Class IIb · n=32MDD 100.0% Class IIb · n=83terminal

              Registered in EUDAMED under MDR with this code: 32 of 32 devices carry Class IIb on their registration (as of 8 Sep 2026).

              • 32 Class IIb (100.0%)

              Registered in EUDAMED under MDD with this code: 83 of 83 devices carry Class IIb on their registration (as of 8 Sep 2026).

              • 83 Class IIb (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070401020199Ptfe Vascular Endoprostheses, Straight - OtherMDD 100.0% Class III · n=51terminal

              Registered in EUDAMED under MDD with this code: 51 of 51 devices carry Class III on their registration (as of 8 Sep 2026).

              • 51 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0704010202Ptfe Vascular Endoprostheses, BifurcatedMDR 100.0% Class III · n=115MDD 100.0% Class III · n=54terminal

            Registered in EUDAMED under MDR with this code: 115 of 115 devices carry Class III on their registration (as of 8 Sep 2026).

            • 115 Class III (100.0%)

            Registered in EUDAMED under MDD with this code: 54 of 54 devices carry Class III on their registration (as of 8 Sep 2026).

            • 54 Class III (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0704010203Ptfe Vascular Endoprostheses, Auxiliaryterminal
        • P07040199Vascular Endoprostheses - OtherMDR 100.0% Class III · n=178MDD 96.8% Class III · n=192terminal

          Registered in EUDAMED under MDR with this code: 178 of 178 devices carry Class III on their registration (as of 8 Sep 2026).

          • 178 Class III (100.0%)

          Registered in EUDAMED under MDD with this code: 186 of 192 devices carry Class III on their registration (as of 8 Sep 2026).

          • 186 Class III (96.8%)
          • 6 Class IIb (3.1%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • P070402Vascular Stents
        • P07040201Coronary Stents
          • P0704020101Coronary Bare Metal Stents (Bms)
            • P070402010101Stainless Steel Coronary Bare Metal Stents (Bms)terminal
            • P070402010102Metallic Non-Stainless Steel Coronary StentsMDD 100.0% Class III · n=212terminal

              Registered in EUDAMED under MDD with this code: 212 of 212 devices carry Class III on their registration (as of 8 Sep 2026).

              • 212 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070402010199Coronary Bare Metal Stents (Bms) - Otherterminal
          • P0704020102Coated Coronary StentsMDD 100.0% Class III · n=60terminal

            Registered in EUDAMED under MDD with this code: 60 of 60 devices carry Class III on their registration (as of 8 Sep 2026).

            • 60 Class III (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0704020103Coronary Drug Eluting Stents (Des)
            • P070402010301Coronary Drug Eluting Stents (Des) with PolymersMDR 100.0% Class III · n=478MDD 100.0% Class III · n=4,977terminal

              Registered in EUDAMED under MDR with this code: 478 of 478 devices carry Class III on their registration (as of 8 Sep 2026).

              • 478 Class III (100.0%)

              Registered in EUDAMED under MDD with this code: 4,977 of 4,977 devices carry Class III on their registration (as of 8 Sep 2026).

              • 4,977 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070402010302Coronary Drug Eluting Stents (Des) without PolymersMDR 100.0% Class III · n=90MDD 100.0% Class III · n=250terminal

              Registered in EUDAMED under MDR with this code: 90 of 90 devices carry Class III on their registration (as of 8 Sep 2026).

              • 90 Class III (100.0%)

              Registered in EUDAMED under MDD with this code: 250 of 250 devices carry Class III on their registration (as of 8 Sep 2026).

              • 250 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0704020104Coronary Stents, AbsorbableMDD 100.0% Class III · n=112terminal

            Registered in EUDAMED under MDD with this code: 112 of 112 devices carry Class III on their registration (as of 8 Sep 2026).

            • 112 Class III (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0704020105Coronary Stents, Bioactiveterminal
          • P0704020199Coronary Stents - Otherterminal
        • P07040202Peripheral Vascular Stents
          • P0704020201Peripheral Vascular Stents, Bms
            • P070402020101Stainless Steel Peripheral Vascular Bare Metal StentsMDD 100.0% Class IIb · n=181terminal

              Registered in EUDAMED under MDD with this code: 181 of 181 devices carry Class IIb on their registration (as of 8 Sep 2026).

              • 181 Class IIb (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070402020102Non-Stainless Steel Peripheral Vascular Bare Metal StentsMDR 2 classes · n=234MDD 98.9% Class IIb · n=1,283terminal

              Registered in EUDAMED under MDR with this code, the 234 devices are split across classes (as of 8 Sep 2026).

              • 121 Class IIb (51.7%)
              • 113 Class III (48.2%)

              Registered in EUDAMED under MDD with this code: 1,269 of 1,283 devices carry Class IIb on their registration (as of 8 Sep 2026).

              • 1,269 Class IIb (98.9%)
              • 13 Class III (1.0%)
              • 1 Class IIa (<0.1%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

            • P070402020199Peripheral Vascular Bare Stents - OtherMDD 100.0% Class III · n=40terminal

              Registered in EUDAMED under MDD with this code: 40 of 40 devices carry Class III on their registration (as of 8 Sep 2026).

              • 40 Class III (100.0%)

              Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0704020202Peripheral Vascular Coated StentsMDR 2 classes · n=179MDD 2 classes · n=32terminal

            Registered in EUDAMED under MDR with this code, the 179 devices are split across classes (as of 8 Sep 2026).

            • 90 Class IIb (50.2%)
            • 89 Class III (49.7%)

            Registered in EUDAMED under MDD with this code, the 32 devices are split across classes (as of 8 Sep 2026).

            • 24 Class IIb (75.0%)
            • 8 Class III (25.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0704020203Peripheral Vascular Drug Eluting Stents (Des)MDR 100.0% Class III · n=71MDD 2 classes · n=118terminal

            Registered in EUDAMED under MDR with this code: 71 of 71 devices carry Class III on their registration (as of 8 Sep 2026).

            • 71 Class III (100.0%)

            Registered in EUDAMED under MDD with this code, the 118 devices are split across classes (as of 8 Sep 2026).

            • 70 Class IIb (59.3%)
            • 48 Class III (40.6%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

          • P0704020204Peripheral Vascular Stents, BioactiveMDR 100.0% Class III · n=136terminal

            Registered in EUDAMED under MDR with this code: 136 of 136 devices carry Class III on their registration (as of 8 Sep 2026).

            • 136 Class III (100.0%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.

          • P0704020299Peripheral Vascular Stents - OtherMDR 3 classes · n=191MDD 2 classes · n=115terminal

            Registered in EUDAMED under MDR with this code, the 191 devices are split across classes (as of 8 Sep 2026).

            • 174 Class III (91.0%)
            • 16 Class IIb (8.3%)
            • 1 Class IIa (0.5%)

            Registered in EUDAMED under MDD with this code, the 115 devices are split across classes (as of 8 Sep 2026).

            • 76 Class IIb (66.0%)
            • 39 Class III (33.9%)

            Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • P070403Cardiac and Coronary Defect Occluders
        • P07040301Cardiac Occluders, Ventricular Septal DefectsMDR 100.0% Class III · n=54MDD 100.0% Class III · n=145terminal

          Registered in EUDAMED under MDR with this code: 54 of 54 devices carry Class III on their registration (as of 8 Sep 2026).

          • 54 Class III (100.0%)

          Registered in EUDAMED under MDD with this code: 145 of 145 devices carry Class III on their registration (as of 8 Sep 2026).

          • 145 Class III (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • P07040302Cardiac Occluders, Atrial Septal DefectsMDR 100.0% Class III · n=212MDD 100.0% Class III · n=128terminal

          Registered in EUDAMED under MDR with this code: 212 of 212 devices carry Class III on their registration (as of 8 Sep 2026).

          • 212 Class III (100.0%)

          Registered in EUDAMED under MDD with this code: 128 of 128 devices carry Class III on their registration (as of 8 Sep 2026).

          • 128 Class III (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • P07040303Cardiac Occluders, Foramen Ovale and Botallo DuctMDR 100.0% Class III · n=67MDD 100.0% Class III · n=66terminal

          Registered in EUDAMED under MDR with this code: 67 of 67 devices carry Class III on their registration (as of 8 Sep 2026).

          • 67 Class III (100.0%)

          Registered in EUDAMED under MDD with this code: 66 of 66 devices carry Class III on their registration (as of 8 Sep 2026).

          • 66 Class III (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

        • P07040399Heart and Coronary Defect Occluders - OtherMDR 100.0% Class III · n=134MDD 100.0% Class III · n=42terminal

          Registered in EUDAMED under MDR with this code: 134 of 134 devices carry Class III on their registration (as of 8 Sep 2026).

          • 134 Class III (100.0%)

          Registered in EUDAMED under MDD with this code: 42 of 42 devices carry Class III on their registration (as of 8 Sep 2026).

          • 42 Class III (100.0%)

          Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

      • P070404Left Atrial Appendage Occludersterminal
    • P0780Vascular and Cardiac Prostheses - AccessoriesMDR 3 classes · n=24MDD 98.4% Class IIa · n=196terminal

      Registered in EUDAMED under MDR with this code, the 24 devices are split across classes (as of 8 Sep 2026).

      • 12 Class III (50.0%)
      • 9 Class IIa (37.5%)
      • 3 Class I (12.5%)

      Registered in EUDAMED under MDD with this code: 193 of 196 devices carry Class IIa on their registration (as of 8 Sep 2026).

      • 193 Class IIa (98.4%)
      • 3 Class III (1.5%)

      Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

    • P0799Vascular and Cardiac Prostheses - OtherMDR 100.0% Class III · n=524MDD 100.0% Class III · n=48terminal

      Registered in EUDAMED under MDR with this code: 524 of 524 devices carry Class III on their registration (as of 8 Sep 2026).

      • 524 Class III (100.0%)

      Registered in EUDAMED under MDD with this code: 48 of 48 devices carry Class III on their registration (as of 8 Sep 2026).

      • 48 Class III (100.0%)

      Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.

How P07 is structured

97
terminal codes, selectable in a device record
41
branch headings, not selectable
75
name a specific device type
23%
fallback entries: Other and Accessories

The Vascular and Cardiac Prostheses branch runs 5 levels deep. 41 entries below are branch headings that group other codes rather than naming a device, so a classification has to resolve all the way down to one of the 97 codes marked terminal.

20 terminal codes are “- Other” entries and 2 are “- Accessories” entries, 23% of the branch. An “- Other” code is the residual slot for devices its siblings do not name, so it is worth ruling out every specific sibling before settling on one.

The largest sub-branch is P0703 (Cardiac Valves), holding 39 of the 97 terminal codes.

Frequently asked questions

Which P07 codes can be used in a EUDAMED device record?
97 of the 138 codes listed under P07 (Vascular and Cardiac Prostheses) are terminal and can be selected. The other 41 are branch headings that cannot.
How deep is the P07 hierarchy?
The P07 branch runs 5 levels below the group code. Its largest sub-branch is P0703 (Cardiac Valves), which holds 39 of the 97 terminal codes.
How many P07 codes are catch-all entries?
20 terminal codes under P07 are "- Other" entries and 2 are "- Accessories" entries, 23% of the branch. The remaining 75 name a specific device type.

Not sure which level to stop at, or which of two plausible codes to submit? The guide to choosing an EMDN code walks the decision level by level, with a worked example and the mistakes that get a EUDAMED registration rejected.

Classifying more than a handful of devices?

EUDAMate maps your device list against all 6,773 terminal EMDN codes with confidence-scored suggestions you review and confirm. Start with a free Readiness Check on your own data.

Run a free Readiness Check

Other groups in category P

Source: European Commission, EMDN v2026 official release. Terminal codes are the only codes accepted in a EUDAMED device record. EMDN is a nomenclature, not a risk classification. MDR/IVDR class is determined separately.