EMDN U02: Ureteral Catheters and Stents
Complete hierarchy for EMDN group U02 in category U (Devices for Urogenital System): 14 terminal codes, EMDN v2026. Terminal codes are the ones accepted in a EUDAMED device record.
Registered classes, as of 8 Sep 2026. For each code with at least 20 registrations under a legislation, the chip shows how devices registered in EUDAMED under that code are classed, counted once per primary UDI-DI and kept separate for each legislation. It is not a determination. The class of a device comes from the MDR and IVDR classification rules for its intended purpose. MDD and IVDD classes are the directive classification and can differ from the class the same device would have under MDR or IVDR.
U02Ureteral Catheters and StentsU0201Ureteral Catheters without BalloonU020101Ureteral Catheters with Cylindrical TipMDR 100.0% Class IIa · n=55MDD 2 classes · n=34terminalRegistered in EUDAMED under MDR with this code: 55 of 55 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 55 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code, the 34 devices are split across classes (as of 8 Sep 2026).
- 24 Class IIa (70.5%)
- 10 Class I (29.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
U020102Ureteral Catheters with Open Flute Beak TipterminalU020103Ureteral Catheters with Chevassu TipterminalRegistered in EUDAMED under MDR with this code: 20 of 20 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 20 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 512 devices are split across classes (as of 8 Sep 2026).
- 469 Class IIa (91.6%)
- 43 Class I (8.3%)
Registered in EUDAMED under MDD with this code, the 94 devices are split across classes (as of 8 Sep 2026).
- 83 Class IIa (88.2%)
- 11 Class I (11.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
U0202Ureteral Catheters with BalloonRegistered in EUDAMED under MDD with this code: 76 of 76 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 76 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 96 of 96 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 96 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
U020299Ureteral Catheters with Balloon - OtherMDR 2 classes · n=360MDD 100.0% Class IIb · n=145terminalRegistered in EUDAMED under MDR with this code, the 360 devices are split across classes (as of 8 Sep 2026).
- 200 Class IIb (55.5%)
- 160 Class IIa (44.4%)
Registered in EUDAMED under MDD with this code: 145 of 145 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 145 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
U0203Ureteral StentsRegistered in EUDAMED under MDR with this code, the 596 devices are split across classes (as of 8 Sep 2026).
- 563 Class IIa (94.4%)
- 18 Class IIb (3.0%)
- 15 Class I (2.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 4,027 devices are split across classes (as of 8 Sep 2026).
- 3,131 Class IIa (77.7%)
- 896 Class IIb (22.2%)
Registered in EUDAMED under MDD with this code: 3,550 of 3,559 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 3,550 Class IIb (99.7%)
- 9 Class IIa (0.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 1,292 of 1,292 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 1,292 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code: 56 of 56 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 56 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 344 of 344 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 344 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 25 devices are split across classes (as of 8 Sep 2026).
- 13 Class IIa (52.0%)
- 12 Class I (48.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 345 devices are split across classes (as of 8 Sep 2026).
- 309 Class IIa (89.5%)
- 34 Class I (9.8%)
- 2 Class IIb (0.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
How U02 is structured
The Ureteral Catheters and Stents branch runs 2 levels deep. 3 entries below are branch headings that group other codes rather than naming a device, so a classification has to resolve all the way down to one of the 14 codes marked terminal.
4 terminal codes are “- Other” entries and 1 is an “- Accessories” entry, 36% of the branch. An “- Other” code is the residual slot for devices its siblings do not name, so it is worth ruling out every specific sibling before settling on one.
The largest sub-branch is U0201 (Ureteral Catheters without Balloon), holding 5 of the 14 terminal codes.
Frequently asked questions
- Which U02 codes can be used in a EUDAMED device record?
- 14 of the 17 codes listed under U02 (Ureteral Catheters and Stents) are terminal and can be selected. The other 3 are branch headings that cannot.
- How deep is the U02 hierarchy?
- The U02 branch runs 2 levels below the group code. Its largest sub-branch is U0201 (Ureteral Catheters without Balloon), which holds 5 of the 14 terminal codes.
- How many U02 codes are catch-all entries?
- 4 terminal codes under U02 are "- Other" entries and 1 is an "- Accessories" entry, 36% of the branch. The remaining 9 name a specific device type.
Not sure which level to stop at, or which of two plausible codes to submit? The guide to choosing an EMDN code walks the decision level by level, with a worked example and the mistakes that get a EUDAMED registration rejected.
Classifying more than a handful of devices?
EUDAMate maps your device list against all 6,773 terminal EMDN codes with confidence-scored suggestions you review and confirm. Start with a free Readiness Check on your own data.
Run a free Readiness CheckOther groups in category U
U01Urethral, Prostatic and Bladder CathetersU10Obstetrics DevicesU11Contraceptive DevicesU12Single-Use Instrumentation for Urogenital System (Non-Endoscopic)U13Solutions and Kits for Bladder Washing and InstillationU03Devices for Urethral, Ureteral and Nephrostomic DilationU04Devices for Percutaneous Urinary Drainage and Nephrostomy CathetersU05Urodynamics DevicesU06Urological GuidewiresU07Devices for the Treatment of IncontinenceU08Gynaecological DevicesU09Urogenital Endoscopic DevicesU14Non-Implantable Devices for Sexual DysfunctionU99Devices for Urogenital System - OtherSource: European Commission, EMDN v2026 official release. Terminal codes are the only codes accepted in a EUDAMED device record. EMDN is a nomenclature, not a risk classification. MDR/IVDR class is determined separately.