EMDN Z12: Instruments for Functional Explorations and Therapeutic Interventions
Complete hierarchy for EMDN group Z12 in category Z (Medical Equipment and Related Accessories, Software and Consumables): 994 terminal codes, EMDN v2026. Terminal codes are the ones accepted in a EUDAMED device record.
Registered classes, as of 8 Sep 2026. For each code with at least 20 registrations under a legislation, the chip shows how devices registered in EUDAMED under that code are classed, counted once per primary UDI-DI and kept separate for each legislation. It is not a determination. The class of a device comes from the MDR and IVDR classification rules for its intended purpose. MDD and IVDD classes are the directive classification and can differ from the class the same device would have under MDR or IVDR.
Z12Instruments for Functional Explorations and Therapeutic InterventionsZ1201General and Multidisciplinary Surgery InstrumentsZ120101Arteriotomy AblatorsterminalRegistered in EUDAMED under MDR with this code, the 188 devices are split across classes (as of 8 Sep 2026).
- 78 Class IIb (41.4%)
- 59 Class IIa (31.3%)
- 51 Class I (27.1%)
Registered in EUDAMED under MDD with this code, the 175 devices are split across classes (as of 8 Sep 2026).
- 158 Class IIa (90.2%)
- 17 Class IIb (9.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDD with this code: 30 of 30 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 30 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120104Self–transfusion EquipmentterminalRegistered in EUDAMED under MDR with this code, the 621 devices are split across classes (as of 8 Sep 2026).
- 509 Class IIa (81.9%)
- 78 Class I (12.5%)
- 26 Class IIb (4.1%)
- 8 Class III (1.2%)
Registered in EUDAMED under MDD with this code: 362 of 368 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 362 Class IIa (98.3%)
- 6 Class IIb (1.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDD with this code: 19 of 20 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 19 Class IIb (95.0%)
- 1 Class IIa (5.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120107Scialytic Lamp Lighting SystemsRegistered in EUDAMED under MDR with this code: 4,213 of 4,213 devices carry Class I on their registration (as of 8 Sep 2026).
- 4,213 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 611 of 611 devices carry Class I on their registration (as of 8 Sep 2026).
- 611 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 478 of 478 devices carry Class I on their registration (as of 8 Sep 2026).
- 478 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12010785Scialytic Lamp Lighting Systems - ConsumablesterminalRegistered in EUDAMED under MDR with this code: 460 of 460 devices carry Class I on their registration (as of 8 Sep 2026).
- 460 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120108Instruments for Ultrasonic SurgeryRegistered in EUDAMED under MDR with this code: 120 of 122 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 120 Class IIb (98.3%)
- 2 Class IIa (1.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 183 devices are split across classes (as of 8 Sep 2026).
- 143 Class IIa (78.1%)
- 21 Class I (11.4%)
- 19 Class IIb (10.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12010882Instruments for Ultrasonic Surgery - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code, the 194 devices are split across classes (as of 8 Sep 2026).
- 96 Class IIa (49.4%)
- 48 Class III (24.7%)
- 38 Class I (19.5%)
- 12 Class IIb (6.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12010892Instruments for Ultrasonic Surgery - Medical Device Softwareterminal
Z120109Electrosurgical InstrumentsZ12010901DiathermocoagulatorsterminalZ12010902Electrosurgical Units (Esu) for General UseMDR 98.4% Class IIb · n=194MDD 98.3% Class IIb · n=560terminalRegistered in EUDAMED under MDR with this code: 191 of 194 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 191 Class IIb (98.4%)
- 3 Class I (1.5%)
Registered in EUDAMED under MDD with this code: 551 of 560 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 551 Class IIb (98.3%)
- 9 Class IIa (1.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12010903Argon Electrosurgical Units (Esu)terminalRegistered in EUDAMED under MDR with this code, the 51 devices are split across classes (as of 8 Sep 2026).
- 39 Class I (76.4%)
- 8 Class IIa (15.6%)
- 4 Class IIb (7.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 38 devices are split across classes (as of 8 Sep 2026).
- 29 Class IIb (76.3%)
- 8 Class I (21.0%)
- 1 Class IIa (2.6%)
Registered in EUDAMED under MDD with this code: 50 of 52 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 50 Class IIb (96.1%)
- 2 Class IIa (3.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 542 devices are split across classes (as of 8 Sep 2026).
- 484 Class I (89.2%)
- 55 Class IIb (10.1%)
- 3 Class IIa (0.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12010982Electrosurgery Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code, the 218 devices are split across classes (as of 8 Sep 2026).
- 154 Class IIb (70.6%)
- 60 Class IIa (27.5%)
- 4 Class I (1.8%)
Registered in EUDAMED under MDD with this code, the 42 devices are split across classes (as of 8 Sep 2026).
- 38 Class IIb (90.4%)
- 4 Class I (9.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12010992Electrosurgery Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 23 devices are split across classes (as of 8 Sep 2026).
- 11 Class IIb (47.8%)
- 9 Class I (39.1%)
- 3 Class IIa (13.0%)
Registered in EUDAMED under MDD with this code, the 33 devices are split across classes (as of 8 Sep 2026).
- 17 Class IIb (51.5%)
- 16 Class I (48.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120110Laser Surgery InstrumentsZ12011001Excimer Surgical LaserterminalZ12011002Carbon Monoxide Surgical LaserterminalRegistered in EUDAMED under MDR with this code: 20 of 20 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 20 Class IIb (100.0%)
Registered in EUDAMED under MDD with this code: 84 of 84 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 84 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011004Krypton Surgical LaserterminalZ12011005Carbon Dioxide Surgical LaserMDR 100.0% Class IIb · n=44MDD 100.0% Class IIb · n=45terminalRegistered in EUDAMED under MDR with this code: 44 of 44 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 44 Class IIb (100.0%)
Registered in EUDAMED under MDD with this code: 45 of 45 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 45 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDD with this code: 59 of 59 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 59 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011007Dye Surgical LaserterminalZ12011008Helium/Neon Surgical LaserterminalZ12011009Copper Vapour Surgical LaserterminalZ12011010Argon/Krypton Surgical LaserterminalZ12011011Ktp Surgical LaserterminalRegistered in EUDAMED under MDD with this code, the 45 devices are split across classes (as of 8 Sep 2026).
- 34 Class IIb (75.5%)
- 11 Class IIa (24.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011013Argon Surgical LaserterminalRegistered in EUDAMED under MDD with this code: 42 of 42 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 42 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011015Ruby Surgical LaserterminalRegistered in EUDAMED under MDR with this code, the 173 devices are split across classes (as of 8 Sep 2026).
- 157 Class IIb (90.7%)
- 16 Class IIa (9.2%)
Registered in EUDAMED under MDD with this code: 133 of 133 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 133 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 43 of 44 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 43 Class IIb (97.7%)
- 1 Class I (2.2%)
Registered in EUDAMED under MDD with this code: 61 of 61 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 61 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011018Helium/Cadmium Surgical LaserterminalRegistered in EUDAMED under MDR with this code: 135 of 140 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 135 Class IIb (96.4%)
- 5 Class IIa (3.5%)
Registered in EUDAMED under MDD with this code: 112 of 112 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 112 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011080Laser Surgery Instruments - Hardware AccessoriesMDR 3 classes · n=391MDD 2 classes · n=41terminalRegistered in EUDAMED under MDR with this code, the 391 devices are split across classes (as of 8 Sep 2026).
- 278 Class IIa (71.0%)
- 59 Class I (15.0%)
- 54 Class IIb (13.8%)
Registered in EUDAMED under MDD with this code, the 41 devices are split across classes (as of 8 Sep 2026).
- 32 Class IIb (78.0%)
- 9 Class IIa (21.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011082Laser Surgery Instruments - Software AccessoriesterminalZ12011085Laser Surgery Instruments - ConsumablesMDR 99.7% Class IIa · n=1,724MDD 98.8% Class IIa · n=89terminalRegistered in EUDAMED under MDR with this code: 1,720 of 1,724 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 1,720 Class IIa (99.7%)
- 4 Class I (0.2%)
Registered in EUDAMED under MDD with this code: 88 of 89 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 88 Class IIa (98.8%)
- 1 Class IIb (1.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011092Laser Surgery Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 166 devices are split across classes (as of 8 Sep 2026).
- 105 Class IIb (63.2%)
- 46 Class IIa (27.7%)
- 15 Class I (9.0%)
Registered in EUDAMED under MDD with this code, the 192 devices are split across classes (as of 8 Sep 2026).
- 177 Class IIa (92.1%)
- 9 Class I (4.6%)
- 6 Class IIb (3.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120111Instruments for Operative MicroscopyRegistered in EUDAMED under MDR with this code: 681 of 685 devices carry Class I on their registration (as of 8 Sep 2026).
- 681 Class I (99.4%)
- 4 Class IIa (0.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12011180Instruments for Operative Microscopy - Hardware AccessoriesZ1201118001Stands for Operative MicroscopyterminalZ1201118099Instruments for Operative Microscopy - Hardware Accessories - OtherMDR 100.0% Class I · n=526terminalRegistered in EUDAMED under MDR with this code: 526 of 526 devices carry Class I on their registration (as of 8 Sep 2026).
- 526 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12011182Instruments for Operative Microscopy - Software AccessoriesterminalZ12011185Instruments for Operative Microscopy - ConsumablesterminalZ12011192Instruments for Operative Microscopy - Medical Device SoftwareterminalZ12011199Instruments for Operative Microscopy – Otherterminal
Z120112Patient Positioning InstrumentsRegistered in EUDAMED under MDR with this code: 101 of 101 devices carry Class I on their registration (as of 8 Sep 2026).
- 101 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 1,729 of 1,729 devices carry Class I on their registration (as of 8 Sep 2026).
- 1,729 Class I (100.0%)
Registered in EUDAMED under MDD with this code: 24 of 24 devices carry Class I on their registration (as of 8 Sep 2026).
- 24 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 2,713 of 2,713 devices carry Class I on their registration (as of 8 Sep 2026).
- 2,713 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12011285Patient Positioning Instruments - ConsumablesMDR 100.0% Class I · n=730MDD 100.0% Class I · n=32terminalRegistered in EUDAMED under MDR with this code: 730 of 730 devices carry Class I on their registration (as of 8 Sep 2026).
- 730 Class I (100.0%)
Registered in EUDAMED under MDD with this code: 32 of 32 devices carry Class I on their registration (as of 8 Sep 2026).
- 32 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 2,257 of 2,258 devices carry Class I on their registration (as of 8 Sep 2026).
- 2,257 Class I (99.9%)
- 1 Class IIb (<0.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120113Cleaning, Disinfection and Sterilisation InstrumentsRegistered in EUDAMED under MDR with this code, the 1,913 devices are split across classes (as of 8 Sep 2026).
- 1,650 Class IIa (86.2%)
- 149 Class IIb (7.7%)
- 114 Class I (5.9%)
Registered in EUDAMED under MDD with this code, the 134 devices are split across classes (as of 8 Sep 2026).
- 116 Class IIb (86.5%)
- 18 Class IIa (13.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 576 of 578 devices carry Class I on their registration (as of 8 Sep 2026).
- 576 Class I (99.6%)
- 2 Class IIb (0.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12011303Chemical Sterilisation EquipmentterminalZ12011304Autoclaves with A Chamber Larger Than or Equal to 1 Standard Sterilisation UnitMDR 98.8% Class IIa · n=504MDD 99.0% Class IIb · n=530terminalRegistered in EUDAMED under MDR with this code: 498 of 504 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 498 Class IIa (98.8%)
- 3 Class I (0.5%)
- 3 Class IIb (0.5%)
Registered in EUDAMED under MDD with this code: 525 of 530 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 525 Class IIb (99.0%)
- 5 Class IIa (0.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011305Small Load Autoclaves with A Chamber Smaller Than 1 Standard Sterilisation UnitMDR 2 classes · n=539MDD 2 classes · n=104terminalRegistered in EUDAMED under MDR with this code, the 539 devices are split across classes (as of 8 Sep 2026).
- 363 Class IIb (67.3%)
- 176 Class IIa (32.6%)
Registered in EUDAMED under MDD with this code, the 104 devices are split across classes (as of 8 Sep 2026).
- 98 Class IIb (94.2%)
- 6 Class IIa (5.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011306Cleaning and Decontamination Systems for General and Multidisciplinary Surgery InstrumentsterminalZ12011307Dry Air SterilisersterminalRegistered in EUDAMED under MDR with this code: 83 of 83 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 83 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code: 36 of 36 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 36 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011310Radiation SterilisersZ1201131001Radiation Sterilisers, X–rayterminalZ1201131002Radiation Sterilisers, Gamma–rayterminalZ1201131003Radiation Sterilisers, MicrowaveterminalZ1201131099Radiation Sterilisers - Otherterminal
Registered in EUDAMED under MDR with this code, the 35 devices are split across classes (as of 8 Sep 2026).
- 17 Class I (48.5%)
- 12 Class IIa (34.2%)
- 6 Class IIb (17.1%)
Registered in EUDAMED under MDD with this code, the 58 devices are split across classes (as of 8 Sep 2026).
- 30 Class IIa (51.7%)
- 28 Class IIb (48.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011312Endoscope DryersterminalZ12011313Endoscope SterilisersterminalRegistered in EUDAMED under MDR with this code: 103 of 103 devices carry Class I on their registration (as of 8 Sep 2026).
- 103 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12011380Cleaning, Disinfection and Sterilisation Instruments - Hardware AccessoriesMDR 95.7% Class I · n=593terminalRegistered in EUDAMED under MDR with this code: 568 of 593 devices carry Class I on their registration (as of 8 Sep 2026).
- 568 Class I (95.7%)
- 19 Class IIa (3.2%)
- 6 Class IIb (1.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12011382Cleaning, Disinfection and Sterilisation Instruments - Software AccessoriesterminalZ12011385Cleaning, Disinfection and Sterilisation Instruments - ConsumablesMDR 3 classes · n=588terminalRegistered in EUDAMED under MDR with this code, the 588 devices are split across classes (as of 8 Sep 2026).
- 297 Class I (50.5%)
- 277 Class IIa (47.1%)
- 14 Class IIb (2.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12011392Cleaning, Disinfection and Sterilisation Instruments - Medical Device SoftwareterminalZ12011399Cleaning, Disinfection and Sterilisation Instruments - OtherMDR 100.0% Class I · n=1,918terminalRegistered in EUDAMED under MDR with this code: 1,918 of 1,918 devices carry Class I on their registration (as of 8 Sep 2026).
- 1,918 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120114Surgical Navigation InstrumentsRegistered in EUDAMED under MDR with this code, the 128 devices are split across classes (as of 8 Sep 2026).
- 73 Class I (57.0%)
- 39 Class IIa (30.4%)
- 16 Class IIb (12.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12011480Surgical Navigation Instruments - Hardware AccessoriesMDR 3 classes · n=469MDD 95.8% Class IIb · n=48terminalRegistered in EUDAMED under MDR with this code, the 469 devices are split across classes (as of 8 Sep 2026).
- 324 Class I (69.0%)
- 139 Class IIa (29.6%)
- 6 Class IIb (1.2%)
Registered in EUDAMED under MDD with this code: 46 of 48 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 46 Class IIb (95.8%)
- 2 Class IIa (4.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 32 devices are split across classes (as of 8 Sep 2026).
- 15 Class IIa (46.8%)
- 15 Class IIb (46.8%)
- 2 Class I (6.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12011485Surgical Navigation Instruments - ConsumablesMDR 3 classes · n=99MDD 2 classes · n=24terminalRegistered in EUDAMED under MDR with this code, the 99 devices are split across classes (as of 8 Sep 2026).
- 54 Class I (54.5%)
- 44 Class IIa (44.4%)
- 1 Class III (1.0%)
Registered in EUDAMED under MDD with this code, the 24 devices are split across classes (as of 8 Sep 2026).
- 20 Class IIa (83.3%)
- 4 Class I (16.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12011492Surgical Navigation Instruments - Medical Device Softwareterminal
Z120190Various Instruments for General and Multidisciplinary SurgeryRegistered in EUDAMED under MDR with this code: 111 of 111 devices carry Class I on their registration (as of 8 Sep 2026).
- 111 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12019002Equipment for the Transport of Organic MaterialterminalRegistered in EUDAMED under MDR with this code, the 314 devices are split across classes (as of 8 Sep 2026).
- 194 Class IIa (61.7%)
- 73 Class I (23.2%)
- 47 Class IIb (14.9%)
Registered in EUDAMED under MDD with this code, the 74 devices are split across classes (as of 8 Sep 2026).
- 45 Class IIb (60.8%)
- 27 Class IIa (36.4%)
- 2 Class III (2.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 133 of 136 devices carry Class I on their registration (as of 8 Sep 2026).
- 133 Class I (97.7%)
- 3 Class IIa (2.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12019005DermographsterminalZ12019006PhotocoagulatorsterminalRegistered in EUDAMED under MDR with this code, the 123 devices are split across classes (as of 8 Sep 2026).
- 83 Class I (67.4%)
- 39 Class IIa (31.7%)
- 1 Class IIb (0.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 41 devices are split across classes (as of 8 Sep 2026).
- 33 Class IIa (80.4%)
- 8 Class I (19.5%)
Registered in EUDAMED under MDD with this code: 58 of 60 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 58 Class IIb (96.6%)
- 2 Class IIa (3.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 101 of 101 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 101 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 112 of 112 devices carry Class I on their registration (as of 8 Sep 2026).
- 112 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12019080Various Instruments for General and Multidisciplinary Surgery - Hardware AccessoriesMDR 3 classes · n=228terminalRegistered in EUDAMED under MDR with this code, the 228 devices are split across classes (as of 8 Sep 2026).
- 196 Class I (85.9%)
- 31 Class IIa (13.5%)
- 1 Class IIb (0.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12019082Various Instruments for General and Multidisciplinary Surgery - Software AccessoriesterminalZ12019085Various Instruments for General and Multidisciplinary Surgery - ConsumablesMDR 3 classes · n=61terminalRegistered in EUDAMED under MDR with this code, the 61 devices are split across classes (as of 8 Sep 2026).
- 37 Class IIa (60.6%)
- 23 Class I (37.7%)
- 1 Class IIb (1.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12019092Various Instruments for General and Multidisciplinary Surgery - Medical Device SoftwareterminalZ12019099Various Instruments for General and Multidisciplinary Surgery - OtherMDR 2 classes · n=749MDD 2 classes · n=29terminalRegistered in EUDAMED under MDR with this code, the 749 devices are split across classes (as of 8 Sep 2026).
- 554 Class I (73.9%)
- 195 Class IIa (26.0%)
Registered in EUDAMED under MDD with this code, the 29 devices are split across classes (as of 8 Sep 2026).
- 27 Class IIa (93.1%)
- 2 Class I (6.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1202Endoscopic and Minimally Invasive Surgery InstrumentsZ120201Remote Control Robotic Endoscopic Surgery InstrumentsRegistered in EUDAMED under MDR with this code, the 126 devices are split across classes (as of 8 Sep 2026).
- 64 Class IIb (50.7%)
- 56 Class I (44.4%)
- 6 Class IIa (4.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020180Remote Control Robot-Assisted Endoscopic Surgery Instruments - Hardware AccessoriesZ1202018001Robotic Arms for VideoendoscopyterminalZ1202018002Command Consoles for Endoscopic SurgeryterminalZ1202018099Remote Control Robot-Assisted Endoscopic Surgery Instruments - Hardware Accessories - OtherMDR 3 classes · n=125terminalRegistered in EUDAMED under MDR with this code, the 125 devices are split across classes (as of 8 Sep 2026).
- 103 Class I (82.4%)
- 19 Class IIb (15.2%)
- 3 Class IIa (2.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020182Remote Control Robotic Endoscopic Surgery Instruments - Software AccessoriesterminalZ12020185Remote Control Robot-Assisted Endoscopic Surgery Instruments - ConsumablesterminalZ12020192Remote Control Robot-Assisted Endoscopic Surgery Instruments - Medical Device SoftwareterminalZ12020199Remote Control Robot-Assisted Endoscopic Surgery Instruments - Otherterminal
Z120202Motorised Instruments for Endoscopic SurgeryZ12020201Motorised Systems for Endoscopic SurgeryterminalZ12020280Motorised Instruments for Endoscopic Surgery - Hardware AccessoriesterminalZ12020282Motorised Instruments for Endoscopic Surgery - Software AccessoriesterminalZ12020285Motorised Instruments for Endoscopic Surgery - ConsumablesterminalZ12020292Motorised Instruments for Endoscopic Surgery - Medical Device Softwareterminal
Z120203Endoscopic Lithotripsy InstrumentsRegistered in EUDAMED under MDD with this code: 21 of 21 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 21 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12020302Ultrasonic Endoscopic LithotriptersterminalZ12020303Electrohydraulic Endoscopic LithotriptersterminalZ12020304Laser Endoscopic LithotriptersterminalZ12020380Endoscopic Lithotripsy Instruments - Hardware AccessoriesterminalZ12020382Endoscopic Lithotripsy Instruments - Software AccessoriesterminalZ12020385Endoscopic Lithotripsy Instruments - ConsumablesterminalZ12020392Endoscopic Lithotripsy Instruments - Medical Device Softwareterminal
Z120204Instruments for the Acquisition and Management of Endoscopic and Minimally Invasive Surgery ImagesZ12020401Integrated Systems for the Acquisition and Management of Endoscopic and Minimally Invasive Surgery ImagesMDR 2 classes · n=450terminalRegistered in EUDAMED under MDR with this code, the 450 devices are split across classes (as of 8 Sep 2026).
- 383 Class I (85.1%)
- 67 Class IIa (14.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 431 devices are split across classes (as of 8 Sep 2026).
- 316 Class I (73.3%)
- 115 Class IIa (26.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 35 devices are split across classes (as of 8 Sep 2026).
- 28 Class I (80.0%)
- 7 Class IIa (20.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020404Remote Control Units for Endoscopy and Minimally Invasive SurgeryterminalRegistered in EUDAMED under MDR with this code: 639 of 656 devices carry Class I on their registration (as of 8 Sep 2026).
- 639 Class I (97.4%)
- 17 Class IIa (2.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 493 devices are split across classes (as of 8 Sep 2026).
- 373 Class I (75.6%)
- 120 Class IIa (24.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020480Instruments for the Acquisition and Management of Endoscopic and Minimally Invasive Surgery Images - Hardware AccessoriesMDR 97.0% Class I · n=301terminalRegistered in EUDAMED under MDR with this code: 292 of 301 devices carry Class I on their registration (as of 8 Sep 2026).
- 292 Class I (97.0%)
- 9 Class IIa (2.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020482Instruments for the Acquisition and Management of Endoscopic and Minimally Invasive Surgery Images - Software AccessoriesterminalZ12020485Instruments for the Acquisition and Management of Endoscopic and Minimally Invasive Surgery Images - ConsumablesMDR 100.0% Class I · n=23terminalRegistered in EUDAMED under MDR with this code: 23 of 23 devices carry Class I on their registration (as of 8 Sep 2026).
- 23 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020492Instruments for the Acquisition and Management of Endoscopic and Minimally Invasive Surgery Images - Medical Device SoftwareMDR 96.6% Class I · n=30terminalRegistered in EUDAMED under MDR with this code: 29 of 30 devices carry Class I on their registration (as of 8 Sep 2026).
- 29 Class I (96.6%)
- 1 Class IIa (3.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020499Instruments for the Acquisition and Management of Endoscopic and Minimally Invasive Surgery Images – OtherMDR 100.0% Class I · n=78terminalRegistered in EUDAMED under MDR with this code: 78 of 78 devices carry Class I on their registration (as of 8 Sep 2026).
- 78 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120205Upper Gastrointestinal Tract Endoscopy InstrumentsRegistered in EUDAMED under MDR with this code: 84 of 84 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 84 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020502DuodenoscopesterminalZ12020503Echo–gastroscopesterminalZ12020504OesophagoscopesterminalZ12020505GastroduodenoscopesterminalZ12020506GastroscopesterminalRegistered in EUDAMED under MDR with this code: 65 of 65 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 65 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020508Video DuodenoscopesterminalZ12020509Video OesophagoscopesterminalRegistered in EUDAMED under MDR with this code: 20 of 20 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 20 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 79 of 79 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 79 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code: 21 of 21 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 21 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12020580Upper Gastrointestinal Tract Endoscopy Instruments - Hardware AccessoriesterminalZ12020582Upper Gastrointestinal Tract Endoscopy Instruments - Software AccessoriesterminalZ12020585Upper Gastrointestinal Tract Endoscopy Instruments - ConsumablesterminalZ12020592Upper Gastrointestinal Tract Endoscopy Instruments - Medical Device SoftwareterminalZ12020599Upper Gastrointestinal Tract Endoscopy Instruments - Otherterminal
Z120206Lower Gastrointestinal Tract Endoscopy InstrumentsRegistered in EUDAMED under MDR with this code: 71 of 71 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 71 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020602SigmoidoscopesterminalRegistered in EUDAMED under MDR with this code: 56 of 56 devices carry Class I on their registration (as of 8 Sep 2026).
- 56 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020604Ultrasonic ProctoscopesterminalZ12020605RectoscopesterminalRegistered in EUDAMED under MDR with this code: 160 of 160 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 160 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code: 47 of 47 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 47 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12020607Video EnteroscopesterminalZ12020608Video SigmoidoscopesterminalZ12020680Lower Gastrointestinal Tract Endoscopy Instruments - Hardware AccessoriesterminalZ12020682Lower Gastrointestinal Tract Endoscopy Instruments - Software AccessoriesterminalZ12020685Lower Gastrointestinal Tract Endoscopy Instruments - ConsumablesMDR 97.1% Class I · n=107MDD 2 classes · n=115terminalRegistered in EUDAMED under MDR with this code: 104 of 107 devices carry Class I on their registration (as of 8 Sep 2026).
- 104 Class I (97.1%)
- 3 Class IIa (2.8%)
Registered in EUDAMED under MDD with this code, the 115 devices are split across classes (as of 8 Sep 2026).
- 76 Class IIa (66.0%)
- 39 Class I (33.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12020692Lower Gastrointestinal Tract Endoscopy Instruments - Medical Device SoftwareterminalZ12020699Lower Gastrointestinal Tract Endoscopy Instruments - Otherterminal
Z120207Genitourinary Endoscopy InstrumentsRegistered in EUDAMED under MDR with this code, the 427 devices are split across classes (as of 8 Sep 2026).
- 390 Class IIa (91.3%)
- 37 Class I (8.6%)
Registered in EUDAMED under MDD with this code: 110 of 110 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 110 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 73 devices are split across classes (as of 8 Sep 2026).
- 41 Class I (56.1%)
- 32 Class IIa (43.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 133 of 135 devices carry Class I on their registration (as of 8 Sep 2026).
- 133 Class I (98.5%)
- 2 Class IIa (1.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 460 of 465 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 460 Class IIa (98.9%)
- 5 Class I (1.0%)
Registered in EUDAMED under MDD with this code: 35 of 35 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 35 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 39 of 39 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 39 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code: 48 of 48 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 48 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12020706PelviscopesterminalRegistered in EUDAMED under MDR with this code: 27 of 28 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 27 Class IIa (96.4%)
- 1 Class I (3.5%)
Registered in EUDAMED under MDD with this code: 61 of 63 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 61 Class IIa (96.8%)
- 1 Class I (1.5%)
- 1 Class IIb (1.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12020708Video Colposcopy InstrumentsZ1202070801Video Colposcopy SystemsterminalZ1202070880Video Colposcopy Instruments - Hardware AccessoriesterminalZ1202070882Video Colposcopy Instruments - Software AccessoriesterminalZ1202070885Video Colposcopy Instruments - ConsumablesterminalZ1202070892Video Colposcopy Instruments - Medical Device Softwareterminal
Registered in EUDAMED under MDR with this code: 69 of 69 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 69 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020710VaginoscopesterminalRegistered in EUDAMED under MDR with this code: 50 of 50 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 50 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 20 of 20 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 20 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 377 of 396 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 377 Class IIa (95.2%)
- 19 Class I (4.7%)
Registered in EUDAMED under MDD with this code: 53 of 53 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 53 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 167 devices are split across classes (as of 8 Sep 2026).
- 156 Class I (93.4%)
- 11 Class IIa (6.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020782Genitourinary Endoscopy Instruments - Software AccessoriesterminalZ12020785Genitourinary Endoscopy Instruments - ConsumablesterminalZ12020792Genitourinary Endoscopy Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 24 devices are split across classes (as of 8 Sep 2026).
- 19 Class IIa (79.1%)
- 5 Class I (20.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120208Pulmonary Endoscopic InstrumentsRegistered in EUDAMED under MDR with this code, the 226 devices are split across classes (as of 8 Sep 2026).
- 201 Class IIa (88.9%)
- 25 Class I (11.0%)
Registered in EUDAMED under MDD with this code, the 32 devices are split across classes (as of 8 Sep 2026).
- 16 Class I (50.0%)
- 16 Class IIa (50.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 372 of 389 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 372 Class IIa (95.6%)
- 17 Class I (4.3%)
Registered in EUDAMED under MDD with this code: 41 of 41 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 41 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12020880Pulmonary Endoscopic Instruments - Hardware AccessoriesterminalZ12020882Pulmonary Endoscopic Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code, the 25 devices are split across classes (as of 8 Sep 2026).
- 16 Class I (64.0%)
- 9 Class IIa (36.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020892Pulmonary Endoscopic Instruments - Medical Device SoftwareterminalZ12020899Pulmonary Endoscopic Instruments - Otherterminal
Z120209Neuroendoscopy InstrumentsZ12020901EncephaloscopesterminalZ12020902NeuroscopesterminalRegistered in EUDAMED under MDR with this code: 52 of 52 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 52 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12020980Neuroendoscopy Instruments - Hardware AccessoriesterminalZ12020982Neuroendoscopy Instruments - Software AccessoriesterminalZ12020985Neuroendoscopy Instruments - ConsumablesterminalZ12020992Neuroendoscopy Instruments - Medical Device SoftwareterminalZ12020999Neuroendoscopy Instruments - Otherterminal
Z120210ENT Endoscopy InstrumentsZ12021001PharyngoscopesterminalZ12021002Video PharyngoscopesterminalRegistered in EUDAMED under MDR with this code: 2,984 of 3,058 devices carry Class I on their registration (as of 8 Sep 2026).
- 2,984 Class I (97.5%)
- 74 Class IIa (2.4%)
Registered in EUDAMED under MDD with this code, the 149 devices are split across classes (as of 8 Sep 2026).
- 125 Class I (83.8%)
- 24 Class IIa (16.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 336 devices are split across classes (as of 8 Sep 2026).
- 315 Class I (93.7%)
- 21 Class IIa (6.2%)
Registered in EUDAMED under MDD with this code, the 41 devices are split across classes (as of 8 Sep 2026).
- 36 Class IIa (87.8%)
- 5 Class I (12.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 26 devices are split across classes (as of 8 Sep 2026).
- 21 Class I (80.7%)
- 5 Class IIa (19.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 184 devices are split across classes (as of 8 Sep 2026).
- 155 Class I (84.2%)
- 29 Class IIa (15.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 421 devices are split across classes (as of 8 Sep 2026).
- 367 Class I (87.1%)
- 54 Class IIa (12.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 396 devices are split across classes (as of 8 Sep 2026).
- 236 Class IIa (59.5%)
- 160 Class I (40.4%)
Registered in EUDAMED under MDD with this code: 20 of 20 devices carry Class I on their registration (as of 8 Sep 2026).
- 20 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 54 of 54 devices carry Class I on their registration (as of 8 Sep 2026).
- 54 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12021010LaryngostroboscopesterminalZ12021011Motorised Rhinoscopy Surgery InstrumentsZ1202101101Motorised Rhinoscopy Surgery SystemsterminalZ1202101180Motorised Rhinoscopy Surgery Instruments - Hardware AccessoriesterminalZ1202101182Motorised Rhinoscopy Surgery Instruments - Software AccessoriesterminalZ1202101185Motorised Rhinoscopy Surgery Instruments - ConsumablesterminalZ1202101192Motorised Rhinoscopy Surgery Instruments - Medical Device Softwareterminal
Registered in EUDAMED under MDR with this code: 47 of 48 devices carry Class I on their registration (as of 8 Sep 2026).
- 47 Class I (97.9%)
- 1 Class IIa (2.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12021082ENT Endoscopy Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 32 of 32 devices carry Class I on their registration (as of 8 Sep 2026).
- 32 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12021092ENT Endoscopy Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code: 93 of 94 devices carry Class I on their registration (as of 8 Sep 2026).
- 93 Class I (98.9%)
- 1 Class IIa (1.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120211Orthopaedic Endoscopy InstrumentsRegistered in EUDAMED under MDR with this code: 315 of 321 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 315 Class IIa (98.1%)
- 6 Class I (1.8%)
Registered in EUDAMED under MDD with this code: 98 of 98 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 98 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12021102Motorised Arthroscopic Surgery InstrumentsRegistered in EUDAMED under MDR with this code, the 39 devices are split across classes (as of 8 Sep 2026).
- 32 Class I (82.0%)
- 7 Class IIa (17.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1202110280Motorised Arthroscopic Surgery Instruments - Hardware AccessoriesterminalZ1202110282Motorised Arthroscopic Surgery Instruments - Software AccessoriesterminalZ1202110285Motorised Arthroscopic Surgery Instruments - ConsumablesterminalZ1202110292Motorised Arthroscopic Surgery Instruments - Medical Device Softwareterminal
Z12021180Orthopaedic Endoscopy Instruments - Hardware AccessoriesterminalZ12021182Orthopaedic Endoscopy Instruments - Software AccessoriesterminalZ12021185Orthopaedic Endoscopy Instruments - ConsumablesterminalZ12021192Orthopaedic Endoscopy Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 120 devices are split across classes (as of 8 Sep 2026).
- 79 Class I (65.8%)
- 41 Class IIa (34.1%)
Registered in EUDAMED under MDD with this code, the 71 devices are split across classes (as of 8 Sep 2026).
- 32 Class I (45.0%)
- 32 Class IIb (45.0%)
- 7 Class IIa (9.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120212Endoscopic Capsules InstrumentsRegistered in EUDAMED under MDD with this code: 33 of 33 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 33 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12021202Endoscopic Capsule Signal ReceiversterminalZ12021280Endoscopic Capsule Signal Receivers - Hardware AccessoriesterminalZ12021282Endoscopic Capsule Signal Receivers - Software AccessoriesterminalZ12021285Endoscopic Capsule Signal Receivers - ConsumablesterminalZ12021292Endoscopic Capsule Signal Receivers - Medical Device Softwareterminal
Z120290Various Instruments for Endoscopy and Mini-Invasive SurgeryZ12029001AmnioscopesterminalZ12029002AngioscopesterminalRegistered in EUDAMED under MDR with this code: 87 of 87 devices carry Class I on their registration (as of 8 Sep 2026).
- 87 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12029004Lacrimal Duct EndoscopesterminalZ12029005Mammary Duct EndoscopesterminalZ12029006Fibroscopes for IntubationterminalZ12029007Infra–red Surgical IlluminatorsterminalRegistered in EUDAMED under MDR with this code, the 53 devices are split across classes (as of 8 Sep 2026).
- 34 Class IIa (64.1%)
- 18 Class IIb (33.9%)
- 1 Class I (1.8%)
Registered in EUDAMED under MDD with this code, the 23 devices are split across classes (as of 8 Sep 2026).
- 11 Class IIb (47.8%)
- 7 Class I (30.4%)
- 5 Class IIa (21.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 310 devices are split across classes (as of 8 Sep 2026).
- 294 Class IIa (94.8%)
- 16 Class I (5.1%)
Registered in EUDAMED under MDD with this code: 88 of 88 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 88 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12029011Optical HeatersterminalZ12029012Endoscopic Phlebotomy Systems with TransilluminationterminalZ12029014Gas Pre–heating UnitsterminalRegistered in EUDAMED under MDR with this code, the 116 devices are split across classes (as of 8 Sep 2026).
- 110 Class I (94.8%)
- 6 Class IIa (5.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 77 of 78 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 77 Class IIa (98.7%)
- 1 Class I (1.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12029017ThoracoscopesterminalZ12029080Various Instruments for Endoscopy and Mini-Invasive Surgery - Hardware AccessoriesMDR 3 classes · n=330terminalRegistered in EUDAMED under MDR with this code, the 330 devices are split across classes (as of 8 Sep 2026).
- 313 Class I (94.8%)
- 14 Class IIa (4.2%)
- 3 Class IIb (0.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12029082Various Instruments for Endoscopy and Mini-Invasive Surgery - Software AccessoriesterminalZ12029085Various Instruments for Endoscopy and Mini-Invasive Surgery - ConsumablesMDR 3 classes · n=518MDD 3 classes · n=31terminalRegistered in EUDAMED under MDR with this code, the 518 devices are split across classes (as of 8 Sep 2026).
- 482 Class I (93.0%)
- 20 Class IIb (3.8%)
- 16 Class IIa (3.0%)
Registered in EUDAMED under MDD with this code, the 31 devices are split across classes (as of 8 Sep 2026).
- 22 Class IIa (70.9%)
- 6 Class IIb (19.3%)
- 3 Class I (9.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12029092Various Instruments for Endoscopy and Mini-Invasive Surgery - Medical Device SoftwareterminalZ12029099Various Instruments for Endoscopy and Mini–invasive Surgery – OtherMDR 3 classes · n=682MDD 2 classes · n=26terminalRegistered in EUDAMED under MDR with this code, the 682 devices are split across classes (as of 8 Sep 2026).
- 391 Class I (57.3%)
- 290 Class IIa (42.5%)
- 1 Class IIb (0.1%)
Registered in EUDAMED under MDD with this code, the 26 devices are split across classes (as of 8 Sep 2026).
- 20 Class IIa (76.9%)
- 6 Class I (23.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203Instruments to Support and Monitor Vital SignsZ120301Anaesthesia and Pulmonary Ventilation Support InstrumentsZ12030101Anaesthesia SystemsRegistered in EUDAMED under MDR with this code, the 133 devices are split across classes (as of 8 Sep 2026).
- 126 Class IIb (94.7%)
- 7 Class IIa (5.2%)
Registered in EUDAMED under MDD with this code: 124 of 127 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 124 Class IIb (97.6%)
- 3 Class IIa (2.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203010180Anaesthesia Systems - Hardware AccessoriesMDR 98.1% Class IIb · n=222MDD 2 classes · n=86terminalRegistered in EUDAMED under MDR with this code: 218 of 222 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 218 Class IIb (98.1%)
- 2 Class I (0.9%)
- 2 Class IIa (0.9%)
Registered in EUDAMED under MDD with this code, the 86 devices are split across classes (as of 8 Sep 2026).
- 76 Class IIb (88.3%)
- 10 Class IIa (11.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203010182Anaesthesia Systems - Software AccessoriesterminalZ1203010185Anaesthesia Systems - ConsumablesterminalZ1203010192Anaesthesia Systems - Medical Device SoftwareterminalZ1203010199Anaesthesia Systems - Otherterminal
Registered in EUDAMED under MDR with this code, the 545 devices are split across classes (as of 8 Sep 2026).
- 438 Class IIa (80.3%)
- 100 Class I (18.3%)
- 7 Class IIb (1.2%)
Registered in EUDAMED under MDD with this code, the 374 devices are split across classes (as of 8 Sep 2026).
- 321 Class IIa (85.8%)
- 53 Class IIb (14.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12030103Pulmonary Ventilators for Non–hospital UseMDR 3 classes · n=21MDD 2 classes · n=388terminalRegistered in EUDAMED under MDR with this code, the 21 devices are split across classes (as of 8 Sep 2026).
- 16 Class IIb (76.1%)
- 4 Class IIa (19.0%)
- 1 Class I (4.7%)
Registered in EUDAMED under MDD with this code, the 388 devices are split across classes (as of 8 Sep 2026).
- 203 Class IIb (52.3%)
- 185 Class IIa (47.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 57 devices are split across classes (as of 8 Sep 2026).
- 49 Class IIb (85.9%)
- 8 Class IIa (14.0%)
Registered in EUDAMED under MDD with this code, the 132 devices are split across classes (as of 8 Sep 2026).
- 118 Class IIb (89.3%)
- 14 Class IIa (10.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12030105Pulmonary Ventilators for Hospital UseZ1203010501High–frequency Pulmonary VentilatorsterminalRegistered in EUDAMED under MDD with this code, the 26 devices are split across classes (as of 8 Sep 2026).
- 24 Class IIa (92.3%)
- 2 Class IIb (7.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203010503Neonatal/Paediatric Pulmonary VentilatorsMDR 100.0% Class IIb · n=25MDD 98.8% Class IIb · n=89terminalRegistered in EUDAMED under MDR with this code: 25 of 25 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 25 Class IIb (100.0%)
Registered in EUDAMED under MDD with this code: 88 of 89 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 88 Class IIb (98.8%)
- 1 Class IIa (1.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203010504Adult and Paediatric/Neonatal Pulmonary VentilatorsMDR 2 classes · n=151MDD 95.7% Class IIb · n=94terminalRegistered in EUDAMED under MDR with this code, the 151 devices are split across classes (as of 8 Sep 2026).
- 119 Class IIb (78.8%)
- 32 Class IIa (21.1%)
Registered in EUDAMED under MDD with this code: 90 of 94 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 90 Class IIb (95.7%)
- 4 Class IIa (4.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203010580Pulmonary Ventilators for Hospital Use - Hardware AccessoriesterminalZ1203010582Pulmonary Ventilators for Hospital Use - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code, the 32 devices are split across classes (as of 8 Sep 2026).
- 23 Class IIa (71.8%)
- 6 Class I (18.7%)
- 3 Class IIb (9.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1203010592Pulmonary Ventilators for Hospital Use - Medical Device SoftwareterminalZ1203010599Pulmonary Ventilators for Hospital Use - Otherterminal
Z12030190Various Instruments for Anaesthesia and Pulmonary Ventilation SupportRegistered in EUDAMED under MDR with this code, the 43 devices are split across classes (as of 8 Sep 2026).
- 30 Class IIa (69.7%)
- 13 Class I (30.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 78 devices are split across classes (as of 8 Sep 2026).
- 70 Class IIb (89.7%)
- 5 Class IIa (6.4%)
- 3 Class I (3.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1203019003Ventilation MonitorsterminalZ1203019004Iron LungsterminalZ1203019005Oxygen Therapy TentsterminalZ1203019080Various Instruments for Anaesthesia and Pulmonary Ventilation Support - Hardware AccessoriesMDR 3 classes · n=253MDD 3 classes · n=114terminalRegistered in EUDAMED under MDR with this code, the 253 devices are split across classes (as of 8 Sep 2026).
- 135 Class I (53.3%)
- 63 Class IIb (24.9%)
- 55 Class IIa (21.7%)
Registered in EUDAMED under MDD with this code, the 114 devices are split across classes (as of 8 Sep 2026).
- 66 Class IIb (57.8%)
- 41 Class IIa (35.9%)
- 7 Class I (6.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203019082Various Instruments for Anaesthesia and Pulmonary Ventilation Support - Software AccessoriesterminalZ1203019085Various Instruments for Anaesthesia and Pulmonary Ventilation Support - ConsumablesMDR 2 classes · n=56terminalRegistered in EUDAMED under MDR with this code, the 56 devices are split across classes (as of 8 Sep 2026).
- 51 Class I (91.0%)
- 5 Class IIa (8.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1203019092Various Instruments for Anaesthesia and Pulmonary Ventilation Support - Medical Device SoftwareterminalZ1203019099Various Instruments for Anaesthesia and Pulmonary Ventilation Support – OtherMDR 3 classes · n=38MDD 3 classes · n=57terminalRegistered in EUDAMED under MDR with this code, the 38 devices are split across classes (as of 8 Sep 2026).
- 22 Class I (57.8%)
- 13 Class IIa (34.2%)
- 3 Class IIb (7.8%)
Registered in EUDAMED under MDD with this code, the 57 devices are split across classes (as of 8 Sep 2026).
- 46 Class IIa (80.7%)
- 10 Class IIb (17.5%)
- 1 Class I (1.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120302Vital Signs Monitoring InstrumentsRegistered in EUDAMED under MDR with this code, the 123 devices are split across classes (as of 8 Sep 2026).
- 85 Class IIb (69.1%)
- 24 Class I (19.5%)
- 14 Class IIa (11.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12030202Multi–parameter Patient MonitorsZ1203020201Multi–parameter Patient Bedside MonitorsMDR 3 classes · n=731MDD 98.1% Class IIb · n=499terminalRegistered in EUDAMED under MDR with this code, the 731 devices are split across classes (as of 8 Sep 2026).
- 577 Class IIb (78.9%)
- 152 Class I (20.7%)
- 2 Class IIa (0.2%)
Registered in EUDAMED under MDD with this code: 490 of 499 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 490 Class IIb (98.1%)
- 9 Class IIa (1.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203020202Transportable/Portable Multi–parameter Patient MonitorsMDR 3 classes · n=300MDD 2 classes · n=143terminalRegistered in EUDAMED under MDR with this code, the 300 devices are split across classes (as of 8 Sep 2026).
- 119 Class IIb (39.6%)
- 104 Class I (34.6%)
- 77 Class IIa (25.6%)
Registered in EUDAMED under MDD with this code, the 143 devices are split across classes (as of 8 Sep 2026).
- 116 Class IIb (81.1%)
- 27 Class IIa (18.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203020280Multi-Parameter Monitors - Hardware AccessoriesMDR 3 classes · n=1,385MDD 2 classes · n=81terminalRegistered in EUDAMED under MDR with this code, the 1,385 devices are split across classes (as of 8 Sep 2026).
- 1,092 Class I (78.8%)
- 168 Class IIb (12.1%)
- 125 Class IIa (9.0%)
Registered in EUDAMED under MDD with this code, the 81 devices are split across classes (as of 8 Sep 2026).
- 55 Class IIb (67.9%)
- 26 Class IIa (32.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 33 devices are split across classes (as of 8 Sep 2026).
- 18 Class IIb (54.5%)
- 12 Class I (36.3%)
- 3 Class IIa (9.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1203020285Multi-Parameter Monitors - ConsumablesMDR 98.4% Class I · n=2,789MDD 3 classes · n=46terminalRegistered in EUDAMED under MDR with this code: 2,747 of 2,789 devices carry Class I on their registration (as of 8 Sep 2026).
- 2,747 Class I (98.4%)
- 33 Class IIb (1.1%)
- 9 Class IIa (0.3%)
Registered in EUDAMED under MDD with this code, the 46 devices are split across classes (as of 8 Sep 2026).
- 22 Class IIa (47.8%)
- 12 Class I (26.0%)
- 12 Class IIb (26.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 28 devices are split across classes (as of 8 Sep 2026).
- 15 Class IIb (53.5%)
- 11 Class IIa (39.2%)
- 2 Class I (7.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 275 devices are split across classes (as of 8 Sep 2026).
- 199 Class I (72.3%)
- 59 Class IIb (21.4%)
- 17 Class IIa (6.1%)
Registered in EUDAMED under MDD with this code, the 71 devices are split across classes (as of 8 Sep 2026).
- 34 Class IIa (47.8%)
- 28 Class IIb (39.4%)
- 9 Class I (12.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12030203Blood Pressure Monitoring InstrumentsZ1203020301Invasive Blood Pressure Monitoring InstrumentsMDR 3 classes · n=1,523MDD 2 classes · n=122terminalRegistered in EUDAMED under MDR with this code, the 1,523 devices are split across classes (as of 8 Sep 2026).
- 929 Class IIb (60.9%)
- 386 Class I (25.3%)
- 208 Class IIa (13.6%)
Registered in EUDAMED under MDD with this code, the 122 devices are split across classes (as of 8 Sep 2026).
- 95 Class IIb (77.8%)
- 27 Class IIa (22.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203020302Non–invasive Blood Pressure Monitoring InstrumentsMDR 3 classes · n=3,045MDD 95.6% Class IIa · n=254terminalRegistered in EUDAMED under MDR with this code, the 3,045 devices are split across classes (as of 8 Sep 2026).
- 2,261 Class I (74.2%)
- 775 Class IIa (25.4%)
- 9 Class IIb (0.2%)
Registered in EUDAMED under MDD with this code: 243 of 254 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 243 Class IIa (95.6%)
- 6 Class IIb (2.3%)
- 5 Class I (1.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12030204Gaseous Exchange Monitoring InstrumentsRegistered in EUDAMED under MDR with this code, the 34 devices are split across classes (as of 8 Sep 2026).
- 28 Class IIb (82.3%)
- 4 Class I (11.7%)
- 2 Class IIa (5.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1203020402Carbon Monoxide AnalysersterminalZ1203020403Oxygen AnalysersterminalZ1203020404Metabolism EquipmentterminalRegistered in EUDAMED under MDR with this code: 43 of 44 devices carry Class I on their registration (as of 8 Sep 2026).
- 43 Class I (97.7%)
- 1 Class IIa (2.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1203020406Cerebral OximetersterminalZ1203020407Subcutaneous OximetersterminalRegistered in EUDAMED under MDR with this code, the 599 devices are split across classes (as of 8 Sep 2026).
- 542 Class IIa (90.4%)
- 56 Class IIb (9.3%)
- 1 Class I (0.1%)
Registered in EUDAMED under MDD with this code, the 380 devices are split across classes (as of 8 Sep 2026).
- 222 Class IIb (58.4%)
- 158 Class IIa (41.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203020480Gaseous Exchange Monitoring Instruments - Hardware AccessoriesMDD 100.0% Class IIa · n=93terminalRegistered in EUDAMED under MDD with this code: 93 of 93 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 93 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203020482Gaseous Exchange Monitoring Instruments - Software AccessoriesterminalZ1203020485Gaseous Exchange Monitoring Instruments - ConsumablesMDR 2 classes · n=134MDD 100.0% Class IIa · n=56terminalRegistered in EUDAMED under MDR with this code, the 134 devices are split across classes (as of 8 Sep 2026).
- 70 Class I (52.2%)
- 64 Class IIa (47.7%)
Registered in EUDAMED under MDD with this code: 56 of 56 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 56 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203020492Gaseous Exchange Monitoring Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 21 devices are split across classes (as of 8 Sep 2026).
- 13 Class IIb (61.9%)
- 7 Class IIa (33.3%)
- 1 Class I (4.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12030205Non–invasive Blood Pressure GaugesZ1203020501Non–invasive Oscillometric Blood Pressure GaugesMDR 97.1% Class IIa · n=1,018MDD 100.0% Class IIa · n=205terminalRegistered in EUDAMED under MDR with this code: 989 of 1,018 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 989 Class IIa (97.1%)
- 29 Class I (2.8%)
Registered in EUDAMED under MDD with this code: 205 of 205 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 205 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 1,330 of 1,348 devices carry Class I on their registration (as of 8 Sep 2026).
- 1,330 Class I (98.6%)
- 18 Class IIa (1.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12030206Vital Signs Telemetry Instruments (ECG, Nipb, Etco2, Spo2, Respiration,...)Z1203020601Complete Vital Signs Telemetry SystemsMDR 2 classes · n=34MDD 100.0% Class IIb · n=26terminalRegistered in EUDAMED under MDR with this code, the 34 devices are split across classes (as of 8 Sep 2026).
- 27 Class IIb (79.4%)
- 7 Class IIa (20.5%)
Registered in EUDAMED under MDD with this code: 26 of 26 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 26 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1203020602Vital Signs Telemetry ReceiversterminalZ1203020603Vital Signs Telemetry TransmitterterminalRegistered in EUDAMED under MDR with this code: 46 of 47 devices carry Class I on their registration (as of 8 Sep 2026).
- 46 Class I (97.8%)
- 1 Class IIb (2.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1203020682Vital Signs Telemetry Instruments - Software AccessoriesterminalZ1203020685Vital Signs Telemetry Instruments - ConsumablesterminalRegistered in EUDAMED under MDR with this code, the 33 devices are split across classes (as of 8 Sep 2026).
- 31 Class IIa (93.9%)
- 2 Class IIb (6.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12030280Vital Signs Monitoring Instruments - Hardware AccessoriesMDR 96.3% Class I · n=626MDD 3 classes · n=38terminalRegistered in EUDAMED under MDR with this code: 603 of 626 devices carry Class I on their registration (as of 8 Sep 2026).
- 603 Class I (96.3%)
- 14 Class IIb (2.2%)
- 9 Class IIa (1.4%)
Registered in EUDAMED under MDD with this code, the 38 devices are split across classes (as of 8 Sep 2026).
- 28 Class IIb (73.6%)
- 6 Class I (15.7%)
- 4 Class IIa (10.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12030282Vital Signs Monitoring Instruments - Software AccessoriesterminalZ12030285Vital Signs Monitoring Instruments - ConsumablesMDR 97.7% Class I · n=3,447MDD 97.0% Class IIb · n=778terminalRegistered in EUDAMED under MDR with this code: 3,369 of 3,447 devices carry Class I on their registration (as of 8 Sep 2026).
- 3,369 Class I (97.7%)
- 61 Class IIb (1.7%)
- 17 Class IIa (0.4%)
Registered in EUDAMED under MDD with this code: 755 of 778 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 755 Class IIb (97.0%)
- 23 Class IIa (2.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 50 devices are split across classes (as of 8 Sep 2026).
- 27 Class IIa (54.0%)
- 15 Class I (30.0%)
- 8 Class IIb (16.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12030299Vital Signs Monitoring Instruments - OtherMDR 3 classes · n=403MDD 2 classes · n=34terminalRegistered in EUDAMED under MDR with this code, the 403 devices are split across classes (as of 8 Sep 2026).
- 326 Class I (80.8%)
- 72 Class IIb (17.8%)
- 5 Class IIa (1.2%)
Registered in EUDAMED under MDD with this code, the 34 devices are split across classes (as of 8 Sep 2026).
- 27 Class IIb (79.4%)
- 7 Class IIa (20.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120303Infusion InstrumentsRegistered in EUDAMED under MDR with this code, the 127 devices are split across classes (as of 8 Sep 2026).
- 117 Class IIb (92.1%)
- 10 Class IIa (7.8%)
Registered in EUDAMED under MDD with this code, the 80 devices are split across classes (as of 8 Sep 2026).
- 66 Class IIb (82.5%)
- 9 Class IIa (11.2%)
- 5 Class I (6.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 98 of 103 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 98 Class IIb (95.1%)
- 4 Class IIa (3.8%)
- 1 Class I (0.9%)
Registered in EUDAMED under MDD with this code: 60 of 62 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 60 Class IIb (96.7%)
- 1 Class I (1.6%)
- 1 Class IIa (1.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 32 of 32 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 32 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code, the 20 devices are split across classes (as of 8 Sep 2026).
- 18 Class IIa (90.0%)
- 2 Class IIb (10.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12030304Infusion RegulatorsterminalRegistered in EUDAMED under MDR with this code, the 49 devices are split across classes (as of 8 Sep 2026).
- 42 Class I (85.7%)
- 7 Class IIa (14.2%)
Registered in EUDAMED under MDD with this code, the 34 devices are split across classes (as of 8 Sep 2026).
- 26 Class I (76.4%)
- 5 Class IIa (14.7%)
- 3 Class IIb (8.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 32 devices are split across classes (as of 8 Sep 2026).
- 23 Class IIb (71.8%)
- 9 Class I (28.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 808 devices are split across classes (as of 8 Sep 2026).
- 762 Class I (94.3%)
- 45 Class IIb (5.5%)
- 1 Class IIa (0.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12030382Infusion Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code, the 94 devices are split across classes (as of 8 Sep 2026).
- 85 Class IIa (90.4%)
- 9 Class I (9.5%)
Registered in EUDAMED under MDD with this code: 71 of 71 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 71 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12030392Infusion Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 118 devices are split across classes (as of 8 Sep 2026).
- 111 Class I (94.0%)
- 4 Class IIa (3.3%)
- 3 Class IIb (2.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 34 devices are split across classes (as of 8 Sep 2026).
- 22 Class IIb (64.7%)
- 12 Class I (35.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120305DefibrillatorsRegistered in EUDAMED under MDR with this code: 188 of 188 devices carry Class III on their registration (as of 8 Sep 2026).
- 188 Class III (100.0%)
Registered in EUDAMED under MDD with this code, the 107 devices are split across classes (as of 8 Sep 2026).
- 66 Class IIb (61.6%)
- 41 Class III (38.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDD with this code: 60 of 61 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 60 Class IIb (98.3%)
- 1 Class III (1.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 166 of 166 devices carry Class III on their registration (as of 8 Sep 2026).
- 166 Class III (100.0%)
Registered in EUDAMED under MDD with this code, the 84 devices are split across classes (as of 8 Sep 2026).
- 44 Class IIb (52.3%)
- 40 Class III (47.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 60 of 60 devices carry Class I on their registration (as of 8 Sep 2026).
- 60 Class I (100.0%)
Registered in EUDAMED under MDD with this code, the 27 devices are split across classes (as of 8 Sep 2026).
- 24 Class IIb (88.8%)
- 3 Class III (11.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12030582Defibrillators - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 50 of 51 devices carry Class I on their registration (as of 8 Sep 2026).
- 50 Class I (98.0%)
- 1 Class IIb (1.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12030592Defibrillators - Medical Device SoftwareterminalZ12030599Defibrillators - Otherterminal
Registered in EUDAMED under MDD with this code: 51 of 51 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 51 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120309Medical/Medicinal Gas Pipeline Systems and Related AccessoriesMDR 3 classes · n=13,837MDD 3 classes · n=5,753terminalRegistered in EUDAMED under MDR with this code, the 13,837 devices are split across classes (as of 8 Sep 2026).
- 8,599 Class IIb (62.1%)
- 5,076 Class IIa (36.6%)
- 162 Class I (1.1%)
Registered in EUDAMED under MDD with this code, the 5,753 devices are split across classes (as of 8 Sep 2026).
- 4,186 Class IIb (72.7%)
- 1,531 Class IIa (26.6%)
- 36 Class I (0.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120390Various Instruments to Support and Monitor Vital SignsZ12039001Intracranial Pressure Measuring SystemsterminalZ12039002Intra Compartmental Pressure Monitor SystemsterminalZ12039080Various Instruments to Support and Monitor Vital Signs - Hardware AccessoriesterminalZ12039082Various Instruments to Support and Monitor Vital Signs - Software AccessoriesterminalZ12039085Various Instruments to Support and Monitor Vital Signs - ConsumablesterminalZ12039092Various Instruments to Support and Monitor Vital Signs - Medical Device SoftwareMDR 3 classes · n=37terminalRegistered in EUDAMED under MDR with this code, the 37 devices are split across classes (as of 8 Sep 2026).
- 30 Class IIa (81.0%)
- 4 Class IIb (10.8%)
- 3 Class I (8.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 29 devices are split across classes (as of 8 Sep 2026).
- 24 Class I (82.7%)
- 4 Class IIb (13.7%)
- 1 Class IIa (3.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1204General Medicine InstrumentsZ120401General Medicine Diagnosis and Monitoring InstrumentsZ12040101AlgesimetersterminalZ12040102Equipment for Analysis of the Physiological Parameters of the SkinterminalZ12040103Hepatic Functionality EquipmentterminalZ12040104Equipment for Diagnosis of the Bioelectric Functional StateMDR 100.0% Class IIa · n=20terminalRegistered in EUDAMED under MDR with this code: 20 of 20 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 20 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 45 of 45 devices carry Class I on their registration (as of 8 Sep 2026).
- 45 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040106Electrocellular Tomography EquipmentterminalZ12040107CapillariscopesterminalRegistered in EUDAMED under MDR with this code: 252 of 252 devices carry Class I on their registration (as of 8 Sep 2026).
- 252 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040109DermohygrometersterminalZ12040110ElectrogustometersterminalRegistered in EUDAMED under MDR with this code, the 88 devices are split across classes (as of 8 Sep 2026).
- 67 Class IIa (76.1%)
- 21 Class I (23.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040112Oncology Tissue InterferometersterminalZ12040113Regional PlethysmographsterminalZ12040114Systems for the Study of Autonomic NeuropathiesterminalZ12040115Blood Sugar Monitoring SystemsRegistered in EUDAMED under MDR with this code: 121 of 127 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 121 Class IIb (95.2%)
- 3 Class I (2.3%)
- 3 Class IIa (2.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 55 devices are split across classes (as of 8 Sep 2026).
- 52 Class IIb (94.5%)
- 3 Class IIa (5.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1204011585Invasive Blood Sugar Monitoring Systems, Single–use SensorsMDR 100.0% Class IIb · n=149MDD 2 classes · n=20terminalRegistered in EUDAMED under MDR with this code: 149 of 149 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 149 Class IIb (100.0%)
Registered in EUDAMED under MDD with this code, the 20 devices are split across classes (as of 8 Sep 2026).
- 13 Class IIb (65.0%)
- 7 Class IIa (35.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 80 devices are split across classes (as of 8 Sep 2026).
- 54 Class IIb (67.5%)
- 21 Class I (26.2%)
- 5 Class IIa (6.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040116Spectrophotometers for Early Detection of MelanomaterminalRegistered in EUDAMED under MDD with this code: 51 of 51 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 51 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 33 of 33 devices carry Class I on their registration (as of 8 Sep 2026).
- 33 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040180General Medicine Diagnosis and Monitoring Instruments - Hardware AccessoriesMDR 99.8% Class I · n=3,375terminalRegistered in EUDAMED under MDR with this code: 3,370 of 3,375 devices carry Class I on their registration (as of 8 Sep 2026).
- 3,370 Class I (99.8%)
- 4 Class IIa (0.1%)
- 1 Class IIb (<0.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040182General Medicine Diagnosis and Monitoring Instruments - Software AccessoriesMDR 3 classes · n=75terminalRegistered in EUDAMED under MDR with this code, the 75 devices are split across classes (as of 8 Sep 2026).
- 46 Class IIa (61.3%)
- 27 Class I (36.0%)
- 2 Class IIb (2.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040185General Medicine Diagnosis and Monitoring Instruments - ConsumablesMDR 2 classes · n=39terminalRegistered in EUDAMED under MDR with this code, the 39 devices are split across classes (as of 8 Sep 2026).
- 37 Class I (94.8%)
- 2 Class IIa (5.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040192General Medicine Diagnosis and Monitoring Instruments - Medical Device SoftwareMDR 4 classes · n=216MDD 3 classes · n=43terminalRegistered in EUDAMED under MDR with this code, the 216 devices are split across classes (as of 8 Sep 2026).
- 149 Class IIa (68.9%)
- 43 Class I (19.9%)
- 20 Class IIb (9.2%)
- 4 Class III (1.8%)
Registered in EUDAMED under MDD with this code, the 43 devices are split across classes (as of 8 Sep 2026).
- 36 Class I (83.7%)
- 5 Class IIa (11.6%)
- 2 Class IIb (4.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 194 devices are split across classes (as of 8 Sep 2026).
- 158 Class I (81.4%)
- 36 Class IIa (18.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120402General Medicine Therapeutic Treatment InstrumentsRegistered in EUDAMED under MDR with this code, the 45 devices are split across classes (as of 8 Sep 2026).
- 41 Class IIa (91.1%)
- 4 Class IIb (8.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 123 devices are split across classes (as of 8 Sep 2026).
- 60 Class IIa (48.7%)
- 37 Class I (30.0%)
- 26 Class IIb (21.1%)
Registered in EUDAMED under MDD with this code, the 141 devices are split across classes (as of 8 Sep 2026).
- 77 Class IIa (54.6%)
- 62 Class IIb (43.9%)
- 2 Class I (1.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 93 devices are split across classes (as of 8 Sep 2026).
- 44 Class IIb (47.3%)
- 38 Class I (40.8%)
- 11 Class IIa (11.8%)
Registered in EUDAMED under MDD with this code, the 29 devices are split across classes (as of 8 Sep 2026).
- 17 Class IIb (58.6%)
- 8 Class IIa (27.5%)
- 4 Class III (13.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 21 devices are split across classes (as of 8 Sep 2026).
- 18 Class I (85.7%)
- 3 Class IIb (14.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040206Mesotherapy EquipmentterminalZ12040207Ozone Therapy EquipmentterminalRegistered in EUDAMED under MDR with this code, the 221 devices are split across classes (as of 8 Sep 2026).
- 183 Class I (82.8%)
- 31 Class IIb (14.0%)
- 7 Class IIa (3.1%)
Registered in EUDAMED under MDD with this code, the 59 devices are split across classes (as of 8 Sep 2026).
- 47 Class IIb (79.6%)
- 12 Class IIa (20.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 161 of 161 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 161 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code: 33 of 33 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 33 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12040211Artificial PancreasterminalZ12040213Patient Washing SystemsterminalRegistered in EUDAMED under MDR with this code, the 44 devices are split across classes (as of 8 Sep 2026).
- 28 Class IIa (63.6%)
- 11 Class IIb (25.0%)
- 5 Class I (11.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040215Multi-District Oncological Therapy Instruments (Excluding Radiotherapy)Z1204021501Multi-District Oncological Hyperthermia EquipmentterminalZ1204021502Tumor Treating Fields (Ttfields) EquipmentterminalZ1204021580Multi-District Oncological Therapy Instruments (Excluding Radiotherapy) - Hardware AccessoriesMDD 97.0% Class IIb · n=34terminalRegistered in EUDAMED under MDD with this code: 33 of 34 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 33 Class IIb (97.0%)
- 1 Class IIa (2.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1204021582Multi-District Oncological Therapy Instruments (Excluding Radiotherapy) - Software AccessoriesterminalZ1204021585Multi-District Oncological Therapy Instruments (Excluding Radiotherapy) - ConsumablesterminalZ1204021592Multi-District Oncological Therapy Instruments (Excluding Radiotherapy) - Medical Device SoftwareterminalZ1204021599Multi-District Oncological Therapy Instruments (Excluding Radiotherapy) - Otherterminal
Z12040216Portable Microinfusion InstrumentsZ1204021601Portable Insulin Infusion InstrumentsZ120402160101Portable Insulin MicroinfusorsMDR 100.0% Class IIb · n=24MDD 100.0% Class IIb · n=41terminalRegistered in EUDAMED under MDR with this code: 24 of 24 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 24 Class IIb (100.0%)
Registered in EUDAMED under MDD with this code: 41 of 41 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 41 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120402160102Portable Insulin Microinfusors with Handheld Glucose MeterterminalZ120402160103Portable Insulin Microinfusors Connectable to Continuous Glucose Monitoring SystemsMDR 2 classes · n=87terminalRegistered in EUDAMED under MDR with this code, the 87 devices are split across classes (as of 8 Sep 2026).
- 82 Class III (94.2%)
- 5 Class IIb (5.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1204021602Portable Pain Therapy InstrumentsterminalZ1204021603Portable Dobutamine Infusion InstrumentsterminalZ1204021680Portable Microinfusion Instruments - Hardware AccessoriesterminalZ1204021685Portable Microinfusion Instruments - ConsumablesterminalZ1204021699Portable Microinfusion Instruments - Otherterminal
Registered in EUDAMED under MDD with this code, the 20 devices are split across classes (as of 8 Sep 2026).
- 14 Class IIb (70.0%)
- 6 Class IIa (30.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12040219Regional Perfusion UnitsterminalZ12040280General Medicine Therapeutic Treatment Instruments - Hardware AccessoriesMDR 3 classes · n=77terminalRegistered in EUDAMED under MDR with this code, the 77 devices are split across classes (as of 8 Sep 2026).
- 68 Class I (88.3%)
- 5 Class IIb (6.4%)
- 4 Class IIa (5.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040282General Medicine Therapeutic Treatment Instruments - Software AccessoriesMDR 3 classes · n=76terminalRegistered in EUDAMED under MDR with this code, the 76 devices are split across classes (as of 8 Sep 2026).
- 38 Class IIa (50.0%)
- 37 Class I (48.6%)
- 1 Class IIb (1.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12040285General Medicine Therapeutic Treatment Instruments - ConsumablesMDR 2 classes · n=86MDD 95.4% Class IIa · n=22terminalRegistered in EUDAMED under MDR with this code, the 86 devices are split across classes (as of 8 Sep 2026).
- 68 Class I (79.0%)
- 18 Class IIb (20.9%)
Registered in EUDAMED under MDD with this code: 21 of 22 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 21 Class IIa (95.4%)
- 1 Class IIb (4.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12040292General Medicine Therapeutic Treatment Instruments - Medical Device SoftwareMDR 3 classes · n=334MDD 97.1% Class I · n=35terminalRegistered in EUDAMED under MDR with this code, the 334 devices are split across classes (as of 8 Sep 2026).
- 271 Class IIb (81.1%)
- 35 Class IIa (10.4%)
- 28 Class I (8.3%)
Registered in EUDAMED under MDD with this code: 34 of 35 devices carry Class I on their registration (as of 8 Sep 2026).
- 34 Class I (97.1%)
- 1 Class IIb (2.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12040299General Medicine Therapeutic Treatment Instruments - OtherMDR 3 classes · n=71MDD 3 classes · n=32terminalRegistered in EUDAMED under MDR with this code, the 71 devices are split across classes (as of 8 Sep 2026).
- 34 Class I (47.8%)
- 31 Class IIa (43.6%)
- 6 Class IIb (8.4%)
Registered in EUDAMED under MDD with this code, the 32 devices are split across classes (as of 8 Sep 2026).
- 19 Class IIb (59.3%)
- 9 Class IIa (28.1%)
- 4 Class I (12.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 488 devices are split across classes (as of 8 Sep 2026).
- 429 Class I (87.9%)
- 58 Class IIa (11.8%)
- 1 Class IIb (0.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1205Cardiology and Cardiosurgery InstrumentsZ120501Stress Analysis InstrumentsRegistered in EUDAMED under MDR with this code: 46 of 47 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 46 Class IIa (97.8%)
- 1 Class I (2.1%)
Registered in EUDAMED under MDD with this code: 26 of 26 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 26 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12050180Stress Analysis Instruments - Hardware AccessoriesterminalZ12050182Stress Analysis Instruments - Software AccessoriesterminalZ12050185Stress Analysis Instruments - ConsumablesterminalZ12050192Stress Analysis Instruments - Medical Device Softwareterminal
Z120502Extra-Corporeal Circulation InstrumentsZ12050201Extra-Corporeal Circulation SystemsterminalRegistered in EUDAMED under MDR with this code, the 40 devices are split across classes (as of 8 Sep 2026).
- 35 Class I (87.5%)
- 5 Class IIb (12.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12050282Extra-Corporeal Circulation Instruments - Software AccessoriesterminalZ12050285Extra-Corporeal Circulation Instruments - ConsumablesterminalZ12050292Extra-Corporeal Circulation Instruments - Medical Device Softwareterminal
Z120503ElectrocardiographsZ12050301General Purpose ElectrocardiographsMDR 2 classes · n=255MDD 100.0% Class IIa · n=125terminalRegistered in EUDAMED under MDR with this code, the 255 devices are split across classes (as of 8 Sep 2026).
- 204 Class IIa (80.0%)
- 51 Class I (20.0%)
Registered in EUDAMED under MDD with this code: 125 of 125 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 125 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDD with this code: 58 of 58 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 58 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12050303CardiophonesterminalRegistered in EUDAMED under MDR with this code: 1,572 of 1,604 devices carry Class I on their registration (as of 8 Sep 2026).
- 1,572 Class I (98.0%)
- 32 Class IIa (1.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12050382Electrocardiographs - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 901 of 902 devices carry Class I on their registration (as of 8 Sep 2026).
- 901 Class I (99.8%)
- 1 Class IIa (0.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 43 devices are split across classes (as of 8 Sep 2026).
- 22 Class IIa (51.1%)
- 20 Class IIb (46.5%)
- 1 Class I (2.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120504Holter System Instruments for Cardiovascular ParametersZ12050401Cardiovascular Holter AnalysersterminalZ12050402Multi–parameter Cardiovascular Holter Recorders (ECG, Nipb, Etc.)terminalRegistered in EUDAMED under MDR with this code, the 171 devices are split across classes (as of 8 Sep 2026).
- 147 Class IIa (85.9%)
- 24 Class I (14.0%)
Registered in EUDAMED under MDD with this code: 83 of 83 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 83 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12050404Blood Pressure Holter RecordersterminalZ12050480Holter System Instruments for Cardiovascular Parameters - Hardware AccessoriesMDR 98.9% Class I · n=97terminalRegistered in EUDAMED under MDR with this code: 96 of 97 devices carry Class I on their registration (as of 8 Sep 2026).
- 96 Class I (98.9%)
- 1 Class IIa (1.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12050482Holter System Instruments for Cardiovascular Parameters - Software AccessoriesterminalZ12050485Holter System Instruments for Cardiovascular Parameters - ConsumablesMDR 100.0% Class I · n=56terminalRegistered in EUDAMED under MDR with this code: 56 of 56 devices carry Class I on their registration (as of 8 Sep 2026).
- 56 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12050492Holter System Instruments for Cardiovascular Parameters - Medical Device SoftwareterminalZ12050499Holter System Instruments for Cardiovascular Parameters – Otherterminal
Z120505Cardiac Output Measurement InstrumentsZ12050501Cardiac Output Measurement MetersterminalRegistered in EUDAMED under MDR with this code, the 22 devices are split across classes (as of 8 Sep 2026).
- 20 Class I (90.9%)
- 2 Class IIa (9.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12050582Cardiac Output Measurement Instruments - Software AccessoriesterminalZ12050585Cardiac Output Measurement Instruments - ConsumablesterminalZ12050592Cardiac Output Measurement Instruments - Medical Device Softwareterminal
Z120506Non–implantable Cardiac StimulatorsZ12050601Transoesophageal Cardiac StimulatorsterminalZ12050602Invasive Cardiac StimulatorsterminalZ12050603Transthoracic Cardiac StimulatorsterminalZ12050680Non-Implantable Cardiac Stimulators - Hardware AccessoriesMDR 100.0% Class I · n=188terminalRegistered in EUDAMED under MDR with this code: 188 of 188 devices carry Class I on their registration (as of 8 Sep 2026).
- 188 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12050682Non-Implantable Cardiac Stimulators - Software AccessoriesterminalZ12050685Non-Implantable Cardiac Stimulators - ConsumablesterminalZ12050692Non-Implantable Cardiac Stimulators - Medical Device SoftwareterminalZ12050699Non–implantable Cardiac Stimulators – Otherterminal
Z120507Cardiography InstrumentsRegistered in EUDAMED under MDR with this code, the 60 devices are split across classes (as of 8 Sep 2026).
- 41 Class I (68.3%)
- 16 Class IIb (26.6%)
- 3 Class IIa (5.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 32 devices are split across classes (as of 8 Sep 2026).
- 21 Class I (65.6%)
- 8 Class IIb (25.0%)
- 3 Class IIa (9.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12050703Polygraphy Systems for Electrophysiological StudiesterminalZ12050780Cardiography Instruments - Hardware AccessoriesZ1205078001Cardiac Electrophysiology StimulatorsterminalZ1205078099Instruments for Cardiological Polygraphy - Hardware Accessories - Otherterminal
Z12050782Instruments for Cardiological Polygraphy - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 83 of 85 devices carry Class I on their registration (as of 8 Sep 2026).
- 83 Class I (97.6%)
- 2 Class IIa (2.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12050792Instruments for Cardiological Polygraphy - Medical Device Softwareterminal
Z120508Cardiac Telemetry InstrumentsZ12050801Complete Cardiac Telemetry SystemsterminalZ12050802Electrocardiograph Telemetry System ReceiversterminalZ12050803Electrocardiograph Telemetry System TransmittersterminalZ12050804Ergospirometric Telemetry TransmittersterminalZ12050880Cardiac Telemetry Instruments - Hardware AccessoriesterminalZ12050882Cardiac Telemetry Instruments - Software AccessoriesterminalZ12050885Cardiac Telemetry Instruments - ConsumablesterminalZ12050892Cardiac Telemetry Instruments - Medical Device SoftwareterminalZ12050899Cardiac Telemetry Instruments - Otherterminal
Z120590Various Instruments for Cardiology and Cardiac SurgeryZ12059001Pacing Sensing AnalysersterminalRegistered in EUDAMED under MDR with this code, the 43 devices are split across classes (as of 8 Sep 2026).
- 31 Class I (72.0%)
- 10 Class IIb (23.2%)
- 2 Class IIa (4.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12059003Clot AspiratorsterminalZ12059004Aortic PumpsterminalZ12059005Blood Flow VelocimetersterminalZ12059006FibrillatorsterminalZ12059007Intra-Cardiac OximetersterminalZ12059008Laser Fluximetry SystemsterminalRegistered in EUDAMED under MDR with this code: 1,009 of 1,027 devices carry Class I on their registration (as of 8 Sep 2026).
- 1,009 Class I (98.2%)
- 18 Class IIa (1.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12059010SternotomesterminalRegistered in EUDAMED under MDR with this code, the 78 devices are split across classes (as of 8 Sep 2026).
- 42 Class I (53.8%)
- 34 Class IIb (43.5%)
- 2 Class IIa (2.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12059012PhonocardiographsterminalZ12059013MagnetocardiographsterminalZ12059080Various Instruments for Cardiology and Cardiac Surgery - Hardware AccessoriesMDR 3 classes · n=90terminalRegistered in EUDAMED under MDR with this code, the 90 devices are split across classes (as of 8 Sep 2026).
- 83 Class I (92.2%)
- 5 Class IIb (5.5%)
- 2 Class IIa (2.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12059082Various Instruments for Cardiology and Cardiac Surgery - Software AccessoriesterminalZ12059085Various Instruments for Cardiology and Cardiac Surgery - ConsumablesterminalZ12059092Various Instruments for Cardiology and Cardiac Surgery - Medical Device SoftwareMDR 3 classes · n=87MDD 3 classes · n=26terminalRegistered in EUDAMED under MDR with this code, the 87 devices are split across classes (as of 8 Sep 2026).
- 73 Class IIb (83.9%)
- 9 Class IIa (10.3%)
- 5 Class I (5.7%)
Registered in EUDAMED under MDD with this code, the 26 devices are split across classes (as of 8 Sep 2026).
- 22 Class IIb (84.6%)
- 3 Class I (11.5%)
- 1 Class IIa (3.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 32 devices are split across classes (as of 8 Sep 2026).
- 11 Class I (34.3%)
- 10 Class IIa (31.2%)
- 8 Class IIb (25.0%)
- 3 Class III (9.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1206Physiotherapy and Rehabilitation InstrumentsRegistered in EUDAMED under MDR with this code, the 264 devices are split across classes (as of 8 Sep 2026).
- 165 Class I (62.5%)
- 78 Class IIa (29.5%)
- 21 Class IIb (7.9%)
Registered in EUDAMED under MDD with this code, the 35 devices are split across classes (as of 8 Sep 2026).
- 30 Class IIa (85.7%)
- 5 Class IIb (14.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 2,051 devices are split across classes (as of 8 Sep 2026).
- 1,603 Class I (78.1%)
- 437 Class IIa (21.3%)
- 11 Class IIb (0.5%)
Registered in EUDAMED under MDD with this code, the 120 devices are split across classes (as of 8 Sep 2026).
- 82 Class IIa (68.3%)
- 23 Class I (19.1%)
- 15 Class IIb (12.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 510 devices are split across classes (as of 8 Sep 2026).
- 445 Class I (87.2%)
- 63 Class IIa (12.3%)
- 2 Class IIb (0.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 43 devices are split across classes (as of 8 Sep 2026).
- 32 Class I (74.4%)
- 11 Class IIa (25.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120605Equipment for Electromyographic AnalysisterminalRegistered in EUDAMED under MDR with this code, the 501 devices are split across classes (as of 8 Sep 2026).
- 443 Class IIa (88.4%)
- 58 Class I (11.5%)
Registered in EUDAMED under MDD with this code, the 61 devices are split across classes (as of 8 Sep 2026).
- 54 Class IIa (88.5%)
- 7 Class I (11.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 715 devices are split across classes (as of 8 Sep 2026).
- 431 Class I (60.2%)
- 284 Class IIa (39.7%)
Registered in EUDAMED under MDD with this code: 183 of 184 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 183 Class IIa (99.4%)
- 1 Class IIb (0.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 513 of 514 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 513 Class IIb (99.8%)
- 1 Class I (0.1%)
Registered in EUDAMED under MDD with this code, the 38 devices are split across classes (as of 8 Sep 2026).
- 27 Class IIa (71.0%)
- 11 Class IIb (28.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120609Shortwave Therapy EquipmentterminalRegistered in EUDAMED under MDR with this code, the 56 devices are split across classes (as of 8 Sep 2026).
- 24 Class I (42.8%)
- 23 Class IIb (41.0%)
- 9 Class IIa (16.0%)
Registered in EUDAMED under MDD with this code, the 42 devices are split across classes (as of 8 Sep 2026).
- 23 Class IIb (54.7%)
- 19 Class IIa (45.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 78 devices are split across classes (as of 8 Sep 2026).
- 55 Class I (70.5%)
- 23 Class IIa (29.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 35 devices are split across classes (as of 8 Sep 2026).
- 18 Class I (51.4%)
- 17 Class IIa (48.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120613Rehabilitative Therapy FurnacesterminalRegistered in EUDAMED under MDR with this code, the 42 devices are split across classes (as of 8 Sep 2026).
- 20 Class I (47.6%)
- 20 Class IIa (47.6%)
- 2 Class IIb (4.7%)
Registered in EUDAMED under MDD with this code, the 36 devices are split across classes (as of 8 Sep 2026).
- 32 Class IIa (88.8%)
- 4 Class I (11.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 186 devices are split across classes (as of 8 Sep 2026).
- 111 Class IIb (59.6%)
- 46 Class IIa (24.7%)
- 29 Class I (15.5%)
Registered in EUDAMED under MDD with this code, the 162 devices are split across classes (as of 8 Sep 2026).
- 140 Class IIb (86.4%)
- 22 Class IIa (13.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 173 devices are split across classes (as of 8 Sep 2026).
- 95 Class I (54.9%)
- 78 Class IIa (45.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120617Movement Analysis Integrated SystemsterminalZ120618Hydrogymnastics and Hydrotherapy SystemsMDR 2 classes · n=132MDD 100.0% Class IIa · n=157terminalRegistered in EUDAMED under MDR with this code, the 132 devices are split across classes (as of 8 Sep 2026).
- 77 Class IIa (58.3%)
- 55 Class I (41.6%)
Registered in EUDAMED under MDD with this code: 157 of 157 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 157 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 34 of 35 devices carry Class I on their registration (as of 8 Sep 2026).
- 34 Class I (97.1%)
- 1 Class IIa (2.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120620Vertebral Column Electroanalgesic StimulatorsterminalRegistered in EUDAMED under MDR with this code: 21 of 21 devices carry Class I on their registration (as of 8 Sep 2026).
- 21 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 113 devices are split across classes (as of 8 Sep 2026).
- 106 Class IIa (93.8%)
- 7 Class I (6.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 32 devices are split across classes (as of 8 Sep 2026).
- 27 Class I (84.3%)
- 5 Class IIa (15.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120624Biofeedback InstrumentsRegistered in EUDAMED under MDR with this code: 31 of 31 devices carry Class I on their registration (as of 8 Sep 2026).
- 31 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12062402Positional Biofeedback SystemsterminalRegistered in EUDAMED under MDR with this code: 69 of 69 devices carry Class I on their registration (as of 8 Sep 2026).
- 69 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 33 of 33 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 33 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 38 of 38 devices carry Class I on their registration (as of 8 Sep 2026).
- 38 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12062482Biofeedback Instruments - Software AccessoriesterminalZ12062485Biofeedback Instruments - ConsumablesterminalZ12062492Biofeedback Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code: 33 of 33 devices carry Class I on their registration (as of 8 Sep 2026).
- 33 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120625Kinematic Motion Capture Analysis SystemsZ12062501Kinematic Goniometric Motion Capture Analysis SystemsterminalZ12062502Kinematic Inertial Motion Capture Analysis SystemsterminalZ12062503Kinematic Optoelectronic Motion Capture Analysis Systems Using Passive MarkersterminalZ12062504Kinematic Optoelectronic Motion Capture Analysis Systems Using Active MarkersterminalZ12062505Kinematic Ultrasound Motion Capture Analysis SystemsterminalZ12062506Kinematic Electromagnetic Field Motion Capture Analysis SystemsterminalZ12062580Kinematic Motion Capture Analysis Systems - Hardware AccessoriesterminalZ12062582Kinematic Motion Capture Analysis Systems - Software AccessoriesterminalZ12062585Kinematic Motion Capture Analysis Systems - ConsumablesterminalZ12062592Kinematic Motion Capture Analysis Systems - Medical Device SoftwareterminalZ12062599Kinematic Motion Capture Analysis Systems - OtherMDR 2 classes · n=32MDD 95.0% Class IIa · n=20terminalRegistered in EUDAMED under MDR with this code, the 32 devices are split across classes (as of 8 Sep 2026).
- 29 Class I (90.6%)
- 3 Class IIa (9.3%)
Registered in EUDAMED under MDD with this code: 19 of 20 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 19 Class IIa (95.0%)
- 1 Class I (5.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120626Dynamometric Systems for Movement AnalysisZ12062601Dynamometric PlatformsterminalRegistered in EUDAMED under MDR with this code: 41 of 41 devices carry Class I on their registration (as of 8 Sep 2026).
- 41 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 48 of 48 devices carry Class I on their registration (as of 8 Sep 2026).
- 48 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12062680Dynamometric Systems for Movement Analysis - Hardware AccessoriesterminalZ12062682Dynamometric Systems for Movement Analysis - Software AccessoriesterminalZ12062685Dynamometric Systems for Movement Analysis - ConsumablesterminalZ12062692Dynamometric Systems for Movement Analysis - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 22 devices are split across classes (as of 8 Sep 2026).
- 15 Class I (68.1%)
- 7 Class IIa (31.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120627Functional Electrical Stimulation SystemsZ12062701Perineal StimulatorsterminalZ12062702Hoisting and Walking StimulatorsterminalZ12062703Cycling StimulatorsterminalZ12062704Prehension StimulatorsterminalZ12062705Myoelectric Control StimulatorsterminalZ12062780Functional Electrical Stimulation Systems - Hardware AccessoriesMDR 2 classes · n=57terminalRegistered in EUDAMED under MDR with this code, the 57 devices are split across classes (as of 8 Sep 2026).
- 45 Class IIa (78.9%)
- 12 Class I (21.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12062782Functional Electrical Stimulation Systems - Software AccessoriesterminalZ12062785Functional Electrical Stimulation Systems - ConsumablesterminalZ12062792Functional Electrical Stimulation Systems - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code: 32 of 32 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 32 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120628Neuromuscular Stimulation EquipmentZ12062801Muscle Reinforcement Stimulators for Innervated MusclesMDR 97.2% Class IIa · n=181MDD 100.0% Class IIa · n=20terminalRegistered in EUDAMED under MDR with this code: 176 of 181 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 176 Class IIa (97.2%)
- 4 Class IIb (2.2%)
- 1 Class I (0.5%)
Registered in EUDAMED under MDD with this code: 20 of 20 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 20 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12062802Stimulators for Scoliosis TreatmentterminalRegistered in EUDAMED under MDR with this code: 28 of 29 devices carry Class I on their registration (as of 8 Sep 2026).
- 28 Class I (96.5%)
- 1 Class IIa (3.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12062882Neuromuscular Stimulation Equipment - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code, the 122 devices are split across classes (as of 8 Sep 2026).
- 102 Class I (83.6%)
- 20 Class IIa (16.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12062892Neuromuscular Stimulation Equipment - Medical Device SoftwareterminalZ12062899Neuromuscular Stimulation Equipment - OtherMDR 2 classes · n=133MDD 2 classes · n=21terminalRegistered in EUDAMED under MDR with this code, the 133 devices are split across classes (as of 8 Sep 2026).
- 110 Class IIa (82.7%)
- 23 Class I (17.2%)
Registered in EUDAMED under MDD with this code, the 21 devices are split across classes (as of 8 Sep 2026).
- 17 Class IIa (80.9%)
- 4 Class IIb (19.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z120690Various Physiotherapy and Rehabilitation InstrumentsRegistered in EUDAMED under MDR with this code: 501 of 501 devices carry Class I on their registration (as of 8 Sep 2026).
- 501 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 24 devices are split across classes (as of 8 Sep 2026).
- 15 Class IIa (62.5%)
- 9 Class I (37.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12069003Cryotherapy ChambersterminalZ12069080Various Physiotherapy and Rehabilitation Instruments - Hardware AccessoriesMDR 2 classes · n=298terminalRegistered in EUDAMED under MDR with this code, the 298 devices are split across classes (as of 8 Sep 2026).
- 278 Class I (93.2%)
- 20 Class IIa (6.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12069082Various Physiotherapy and Rehabilitation Instruments - Software AccessoriesterminalZ12069085Various Physiotherapy and Rehabilitation Instruments - Specific MaterialsterminalZ12069092Various Physiotherapy and Rehabilitation Instruments - Medical Device SoftwareMDR 2 classes · n=141terminalRegistered in EUDAMED under MDR with this code, the 141 devices are split across classes (as of 8 Sep 2026).
- 106 Class I (75.1%)
- 35 Class IIa (24.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12069099Various Physiotherapy and Rehabilitation Instruments - OtherMDR 95.7% Class I · n=2,807MDD 3 classes · n=47terminalRegistered in EUDAMED under MDR with this code: 2,689 of 2,807 devices carry Class I on their registration (as of 8 Sep 2026).
- 2,689 Class I (95.7%)
- 89 Class IIa (3.1%)
- 29 Class IIb (1.0%)
Registered in EUDAMED under MDD with this code, the 47 devices are split across classes (as of 8 Sep 2026).
- 24 Class IIa (51.0%)
- 22 Class I (46.8%)
- 1 Class IIb (2.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1207Gastroenterological InstrumentsZ120701Gastroenterological Manometry EquipmentterminalZ120702Gastroesophageal Ph Holter RecordersterminalZ120703Oesophageal Functionality Analysis EquipmentterminalRegistered in EUDAMED under MDR with this code, the 39 devices are split across classes (as of 8 Sep 2026).
- 32 Class IIa (82.0%)
- 7 Class I (17.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120706Equipment for Radiofrequency Treatment of the CardiasterminalZ120707Lactose Intolerance EquipmentterminalZ120780Gastroenterology Instruments - Hardware AccessoriesterminalZ120782Gastroenterology Instruments - Software AccessoriesterminalZ120785Gastroenterology Instruments - ConsumablesterminalZ120792Gastroenterology Instruments - Medical Device SoftwareterminalZ120799Gastroenterology Instruments -Otherterminal
Z1208Obstetrics and Gynaecology InstrumentsZ120801Prenatal Diagnostic InstrumentsRegistered in EUDAMED under MDR with this code, the 89 devices are split across classes (as of 8 Sep 2026).
- 56 Class IIb (62.9%)
- 20 Class IIa (22.4%)
- 13 Class I (14.6%)
Registered in EUDAMED under MDD with this code, the 107 devices are split across classes (as of 8 Sep 2026).
- 98 Class IIa (91.5%)
- 9 Class IIb (8.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12080102Foetal Ph MonitorsterminalRegistered in EUDAMED under MDR with this code: 65 of 65 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 65 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12080104Cardiotocographic Telemetry InstrumentsZ1208010401Complete Cardiotocographic Telemetry SystemsterminalZ1208010402Receiving Units for Cardiotocographic TelemetryterminalZ1208010403Transmitting Units for Cardiotocographic TelemetryterminalZ1208010480Cardiotocographic Telemetry Instruments - Hardware AccessoriesterminalZ1208010482Cardiotocographic Telemetry Instruments - Software AccessoriesterminalZ1208010485Cardiotocographic Telemetry Instruments - ConsumablesterminalZ1208010492Cardiotocographic Telemetry Instruments - Medical Device SoftwareterminalZ1208010499Cardiotocographic Telemetry Instruments - Otherterminal
Z12080105Foetal Acoustic StimulatorsterminalZ12080180Prenatal Diagnostic Instruments - Hardware AccessoriesterminalRegistered in EUDAMED under MDR with this code: 39 of 39 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 39 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 30 of 30 devices carry Class I on their registration (as of 8 Sep 2026).
- 30 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12080192Prenatal Diagnostic Instruments - Medical Device SoftwareterminalZ12080199Prenatal Diagnostic Instruments - Otherterminal
Z120802Gynaecology and Fertility Treatment InstrumentsZ12080201Endometrial Ablation EquipmentterminalZ12080202Oocyte Aspiration EquipmentterminalZ12080203Hysterosuction Surgical AspiratorsterminalRegistered in EUDAMED under MDR with this code, the 36 devices are split across classes (as of 8 Sep 2026).
- 32 Class IIa (88.8%)
- 4 Class IIb (11.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12080205Oocyte Laser DrillsterminalZ12080280Gynaecology and Fertility Treatment Instruments - Hardware AccessoriesMDD 2 classes · n=27terminalRegistered in EUDAMED under MDD with this code, the 27 devices are split across classes (as of 8 Sep 2026).
- 18 Class I (66.6%)
- 9 Class IIa (33.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12080282Gynaecology and Fertility Treatment Instruments - Software AccessoriesterminalZ12080285Gynaecology and Fertility Treatment Instruments - ConsumablesterminalZ12080292Gynaecology and Fertility Treatment Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 75 devices are split across classes (as of 8 Sep 2026).
- 59 Class I (78.6%)
- 12 Class IIa (16.0%)
- 4 Class IIb (5.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120803Childbirth Support and Maternal Assistance InstrumentsRegistered in EUDAMED under MDR with this code, the 39 devices are split across classes (as of 8 Sep 2026).
- 25 Class IIa (64.1%)
- 14 Class I (35.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 76 of 78 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 76 Class IIa (97.4%)
- 2 Class I (2.5%)
Registered in EUDAMED under MDD with this code: 35 of 35 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 35 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 24 of 24 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 24 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12080305Birthing BathsterminalZ12080380Various Childbirth Support and Maternal Assistance Instruments - Hardware AccessoriesMDR 100.0% Class I · n=52terminalRegistered in EUDAMED under MDR with this code: 52 of 52 devices carry Class I on their registration (as of 8 Sep 2026).
- 52 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12080382Various Childbirth Support and Maternal Assistance Instruments - Software AccessoriesterminalZ12080385Various Childbirth Support and Maternal Assistance Instruments - ConsumablesterminalZ12080392Various Childbirth Support and Maternal Assistance Instruments - Medical Device SoftwareterminalZ12080399Various Childbirth Support and Maternal Assistance Instruments - OtherMDR 2 classes · n=186terminalRegistered in EUDAMED under MDR with this code, the 186 devices are split across classes (as of 8 Sep 2026).
- 151 Class IIa (81.1%)
- 35 Class I (18.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z120804Neonatology InstrumentsRegistered in EUDAMED under MDR with this code, the 115 devices are split across classes (as of 8 Sep 2026).
- 107 Class IIa (93.0%)
- 8 Class I (6.9%)
Registered in EUDAMED under MDD with this code: 141 of 143 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 141 Class IIa (98.6%)
- 2 Class IIb (1.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 59 of 59 devices carry Class I on their registration (as of 8 Sep 2026).
- 59 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12080403Neonatal IncubatorsRegistered in EUDAMED under MDR with this code: 56 of 58 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 56 Class IIb (96.5%)
- 2 Class I (3.4%)
Registered in EUDAMED under MDD with this code: 68 of 68 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 68 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 65 of 65 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 65 Class IIb (100.0%)
Registered in EUDAMED under MDD with this code: 65 of 65 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 65 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1208040380Neonatal Incubators - Hardware AccessoriesterminalZ1208040382Neonatal Incubators - Software AccessoriesterminalZ1208040385Neonatal Incubators - ConsumablesterminalZ1208040392Neonatal Incubators - Medical Device Softwareterminal
Z12080404Paediatric Infrared LampsterminalZ12080405Neonatal Resuscitation BedsterminalZ12080406Apnoea MonitorsterminalRegistered in EUDAMED under MDR with this code, the 68 devices are split across classes (as of 8 Sep 2026).
- 61 Class IIb (89.7%)
- 5 Class I (7.3%)
- 2 Class IIa (2.9%)
Registered in EUDAMED under MDD with this code, the 70 devices are split across classes (as of 8 Sep 2026).
- 65 Class IIb (92.8%)
- 5 Class IIa (7.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12080408Sweat Test StimulatorsterminalZ12080409Infrared Cerebral TopographsterminalZ12080410Transcutaneous BilirubinometersterminalZ12080480Neonatology Instruments - Hardware AccessoriesterminalZ12080482Neonatology Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 41 of 41 devices carry Class I on their registration (as of 8 Sep 2026).
- 41 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12080492Neonatology Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 32 devices are split across classes (as of 8 Sep 2026).
- 25 Class I (78.1%)
- 7 Class IIb (21.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 23 devices are split across classes (as of 8 Sep 2026).
- 17 Class I (73.9%)
- 6 Class IIa (26.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1209Nephrology and Haemodialysis InstrumentsZ120901Peritoneal Dialysis InstrumentsZ12090101Peritoneal Dialysis EquipmentterminalZ12090180Peritoneal Dialysis Instruments - Hardware AccessoriesterminalZ12090182Peritoneal Dialysis Instruments - Software AccessoriesterminalZ12090185Peritoneal Dialysis Instruments - ConsumablesterminalZ12090192Peritoneal Dialysis Instruments - Medical Device Softwareterminal
Z120902Haemodialysis InstrumentsRegistered in EUDAMED under MDR with this code: 46 of 46 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 46 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12090280Haemodialysis Instruments - Hardware AccessoriesterminalZ12090282Haemodialysis Instruments - Software AccessoriesterminalZ12090285Haemodialysis Instruments - ConsumablesterminalZ12090292Haemodialysis Instruments - Medical Device Softwareterminal
Z120903Haemofiltration InstrumentsZ12090301Haemofiltration EquipmentterminalZ12090380Haemofiltration Instruments - Hardware AccessoriesterminalZ12090382Haemofiltration Instruments - Software AccessoriesterminalZ12090385Haemofiltration Instruments - ConsumablesterminalZ12090392Haemofiltration Instruments - Medical Device Softwareterminal
Z120990Various Nephrology and Haemodialysis InstrumentsRegistered in EUDAMED under MDR with this code, the 52 devices are split across classes (as of 8 Sep 2026).
- 43 Class IIa (82.6%)
- 9 Class I (17.3%)
Registered in EUDAMED under MDD with this code: 25 of 25 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 25 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12099002Monitoring Centres for Dialysis TreatmentterminalZ12099003Hospital Beds or Armchair Scales for DialysisterminalZ12099004Heparin PumpsterminalZ12099005Blood PumpsterminalRegistered in EUDAMED under MDR with this code: 234 of 234 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 234 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12099007Dialysis Water Treatment SystemsMDR 97.9% Class IIb · n=484MDD 100.0% Class IIb · n=122terminalRegistered in EUDAMED under MDR with this code: 474 of 484 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 474 Class IIb (97.9%)
- 10 Class IIa (2.0%)
Registered in EUDAMED under MDD with this code: 122 of 122 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 122 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12099080Various Nephrology and Haemodialysis Instruments - Hardware AccessoriesterminalZ12099082Various Nephrology and Haemodialysis Instruments - Software AccessoriesterminalZ12099085Various Nephrology and Haemodialysis Instruments - ConsumablesterminalZ12099092Various Nephrology and Haemodialysis Instruments - Medical Device SoftwareterminalZ12099099Various Nephrology and Haemodialysis Instruments - Otherterminal
Z1210Neurology and Neurosurgery InstrumentsZ121001Radiofrequency Nervous Tissue Ablation InstrumentsterminalRegistered in EUDAMED under MDR with this code, the 318 devices are split across classes (as of 8 Sep 2026).
- 190 Class IIa (59.7%)
- 120 Class I (37.7%)
- 8 Class IIb (2.5%)
Registered in EUDAMED under MDD with this code, the 308 devices are split across classes (as of 8 Sep 2026).
- 231 Class IIa (75.0%)
- 77 Class I (25.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z121003Electroencephalography InstrumentsZ12100301EEG Spectral AnalysersterminalRegistered in EUDAMED under MDR with this code, the 152 devices are split across classes (as of 8 Sep 2026).
- 117 Class IIa (76.9%)
- 22 Class I (14.4%)
- 13 Class IIb (8.5%)
Registered in EUDAMED under MDD with this code, the 27 devices are split across classes (as of 8 Sep 2026).
- 25 Class IIa (92.5%)
- 2 Class IIb (7.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDD with this code: 214 of 214 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 214 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 241 of 250 devices carry Class I on their registration (as of 8 Sep 2026).
- 241 Class I (96.4%)
- 7 Class IIa (2.8%)
- 2 Class IIb (0.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100382Electroencephalography Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 24 of 25 devices carry Class I on their registration (as of 8 Sep 2026).
- 24 Class I (96.0%)
- 1 Class IIa (4.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100392Electroencephalography Instruments - Medical Device Softwareterminal
Z121004Electromyography InstrumentsRegistered in EUDAMED under MDR with this code, the 34 devices are split across classes (as of 8 Sep 2026).
- 15 Class IIb (44.1%)
- 10 Class I (29.4%)
- 9 Class IIa (26.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 160 devices are split across classes (as of 8 Sep 2026).
- 86 Class I (53.7%)
- 38 Class IIa (23.7%)
- 36 Class IIb (22.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100482Electromyography Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code, the 48 devices are split across classes (as of 8 Sep 2026).
- 45 Class IIa (93.7%)
- 3 Class I (6.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100492Electromyography Instruments -Medical Device Softwareterminal
Z121005Polysomnography InstrumentsRegistered in EUDAMED under MDR with this code: 177 of 181 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 177 Class IIa (97.7%)
- 4 Class I (2.2%)
Registered in EUDAMED under MDD with this code: 55 of 55 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 55 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 268 devices are split across classes (as of 8 Sep 2026).
- 230 Class I (85.8%)
- 38 Class IIa (14.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100582Polysomnography Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 418 of 430 devices carry Class I on their registration (as of 8 Sep 2026).
- 418 Class I (97.2%)
- 12 Class IIa (2.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100592Polysomnography Instruments - Medical Device Softwareterminal
Z121006Stereotactic Neurosurgery InstrumentsZ12100601Stereotactic Neurosurgery SystemsterminalZ12100680Stereotactic Neurosurgery Instruments - Hardware AccessoriesMDR 97.5% Class I · n=165terminalRegistered in EUDAMED under MDR with this code: 161 of 165 devices carry Class I on their registration (as of 8 Sep 2026).
- 161 Class I (97.5%)
- 4 Class IIa (2.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100682Stereotactic Neurosurgery Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code, the 22 devices are split across classes (as of 8 Sep 2026).
- 13 Class I (59.0%)
- 6 Class IIa (27.2%)
- 3 Class III (13.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100692Stereotactic Neurosurgery Instruments - Medical Device Softwareterminal
Z121007Electromyographic (EMG) Telemetry InstrumentsRegistered in EUDAMED under MDR with this code, the 30 devices are split across classes (as of 8 Sep 2026).
- 27 Class I (90.0%)
- 3 Class IIa (10.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100702EMG Telemetric TransmittersterminalZ12100703EMG Telemetry ReceiversterminalRegistered in EUDAMED under MDR with this code: 63 of 63 devices carry Class I on their registration (as of 8 Sep 2026).
- 63 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100782EMG Telemetry Instruments - Software AccessoriesterminalZ12100785EMG Telemetry Instruments - ConsumablesterminalZ12100792EMG Telemetry Instruments - Medical Device Softwareterminal
Z121008Electroencephalographic (EEG) Telemetry InstrumentsZ12100801EEG Telemetry SystemsterminalZ12100802EEG Telemetry TransmittersterminalZ12100803EEG Telemetry ReceiversterminalZ12100880EEG Telemetry Instruments - Hardware AccessoriesterminalZ12100882EEG Telemetry Instruments - Software AccessoriesterminalZ12100885EEG Telemetry Instruments - ConsumablesterminalZ12100892EEG Telemetry Instruments - Medical Device Softwareterminal
Z121009Instruments for Motorised Neurosurgery SystemsZ12100901Motorised Neurosurgery SystemsterminalRegistered in EUDAMED under MDD with this code: 88 of 91 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 88 Class IIa (96.7%)
- 3 Class III (3.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12100980Instruments for Motorised Neurosurgery Systems - Hardware AccessoriesMDR 99.2% Class IIa · n=987terminalRegistered in EUDAMED under MDR with this code: 980 of 987 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 980 Class IIa (99.2%)
- 7 Class I (0.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12100982Instruments for Motorised Neurosurgery Systems - Software AccessoriesterminalZ12100985Instruments for Motorised Neurosurgery Systems - ConsumablesMDD 100.0% Class IIa · n=299terminalRegistered in EUDAMED under MDD with this code: 299 of 299 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 299 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12100992Instruments for Motorised Neurosurgery Systems - Medical Device Softwareterminal
Z121010Electroencephalographic (EEG) Holter Systems InstrumentsZ12101001EEG Holter SystemsterminalZ12101002EEG Holter ReadersterminalZ12101003EEG Holter RecordersterminalZ12101080EEG Holter Systems Instruments - Hardware AccessoriesterminalZ12101082EEG Holter Systems Instruments - Software AccessoriesterminalZ12101085EEG Holter Systems Instruments - ConsumablesterminalZ12101092EEG Holter Systems Instruments - Medical Device Softwareterminal
Z121011Peripheral or Central Neuro Stimulation and Assessment InstrumentsZ12101101Somatosensory Evoked Potential AnalysersterminalRegistered in EUDAMED under MDR with this code, the 27 devices are split across classes (as of 8 Sep 2026).
- 24 Class I (88.8%)
- 3 Class IIb (11.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12101103Somatosensory Evoked Potential Integrated SystemsterminalZ12101104Cerebral Mapping SystemsterminalRegistered in EUDAMED under MDR with this code, the 76 devices are split across classes (as of 8 Sep 2026).
- 43 Class IIa (56.5%)
- 33 Class IIb (43.4%)
Registered in EUDAMED under MDD with this code: 28 of 29 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 28 Class IIa (96.5%)
- 1 Class IIb (3.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 102 devices are split across classes (as of 8 Sep 2026).
- 61 Class I (59.8%)
- 41 Class IIa (40.1%)
Registered in EUDAMED under MDD with this code: 51 of 53 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 51 Class IIa (96.2%)
- 2 Class IIb (3.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12101180Peripheral or Central Neuro Stimulation and Assessment Instruments - Hardware AccessoriesMDR 2 classes · n=26terminalRegistered in EUDAMED under MDR with this code, the 26 devices are split across classes (as of 8 Sep 2026).
- 24 Class I (92.3%)
- 2 Class IIa (7.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12101182Peripheral or Central Neuro Stimulation and Assessment Instruments - Software AccessoriesterminalZ12101185Peripheral or Central Neuro Stimulation and Assessment Instruments - ConsumablesMDR 3 classes · n=50MDD 100.0% Class IIa · n=110terminalRegistered in EUDAMED under MDR with this code, the 50 devices are split across classes (as of 8 Sep 2026).
- 46 Class I (92.0%)
- 2 Class IIa (4.0%)
- 2 Class IIb (4.0%)
Registered in EUDAMED under MDD with this code: 110 of 110 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 110 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12101192Peripheral or Central Neuro Stimulation and Assessment Instruments - Medical Device SoftwareterminalZ12101199Peripheral or Central Neuro Stimulation and Assessment Instruments - Otherterminal
Z121012Magnetoencephalography InstrumentsZ12101201Magnetoencephalography SystemsterminalZ12101280Magnetoencephalography Instruments – Hardware AccessoriesterminalZ12101282Magnetoencephalography Instruments – Software AccessoriesterminalZ12101285Magnetoencephalography Instruments - ConsumablesterminalZ12101292Magnetoencephalography Instruments – Medical Device Softwareterminal
Z121090Various Neurology and Neurosurgery InstrumentsZ12109001Detachable Coil Equipment for Brain AneurysmsMDR 98.3% Class III · n=246MDD 99.1% Class III · n=115terminalRegistered in EUDAMED under MDR with this code: 242 of 246 devices carry Class III on their registration (as of 8 Sep 2026).
- 242 Class III (98.3%)
- 2 Class I (0.8%)
- 1 Class IIa (0.4%)
- 1 Class IIb (0.4%)
Registered in EUDAMED under MDD with this code: 114 of 115 devices carry Class III on their registration (as of 8 Sep 2026).
- 114 Class III (99.1%)
- 1 Class IIb (0.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 67 of 67 devices carry Class I on their registration (as of 8 Sep 2026).
- 67 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12109003Cerebrospinal Fluid Pressure Monitoring SystemsterminalZ12109004Vibration Threshold Meters (Vibrometer)terminalZ12109005Reaction Time/Reflex MetersterminalRegistered in EUDAMED under MDR with this code, the 20 devices are split across classes (as of 8 Sep 2026).
- 14 Class I (70.0%)
- 5 Class IIa (25.0%)
- 1 Class III (5.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12109007Psychometric Testing SystemsterminalZ12109080Various Neurology and Neurosurgery Instruments - Hardware AccessoriesMDR 3 classes · n=221terminalRegistered in EUDAMED under MDR with this code, the 221 devices are split across classes (as of 8 Sep 2026).
- 204 Class I (92.3%)
- 13 Class IIa (5.8%)
- 4 Class IIb (1.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12109082Various Neurology and Neurosurgery Instruments - Software AccessoriesterminalZ12109085Various Neurology and Neurosurgery Instruments - Specific MaterialsterminalZ12109092Various Neurology and Neurosurgery Instruments - Medical Device SoftwareterminalZ12109099Various Neurology and Neurosurgery Instruments - OtherMDR 3 classes · n=42MDD 98.4% Class III · n=130terminalRegistered in EUDAMED under MDR with this code, the 42 devices are split across classes (as of 8 Sep 2026).
- 19 Class IIa (45.2%)
- 14 Class III (33.3%)
- 9 Class IIb (21.4%)
Registered in EUDAMED under MDD with this code: 128 of 130 devices carry Class III on their registration (as of 8 Sep 2026).
- 128 Class III (98.4%)
- 2 Class IIa (1.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1211Dental Stomatology InstrumentsZ121101Instruments for Dental Treatment UnitsRegistered in EUDAMED under MDR with this code, the 1,030 devices are split across classes (as of 8 Sep 2026).
- 743 Class IIa (72.1%)
- 287 Class I (27.8%)
Registered in EUDAMED under MDD with this code: 131 of 136 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 131 Class IIa (96.3%)
- 3 Class I (2.2%)
- 1 Class IIb (0.7%)
- 1 Class III (0.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 58,703 of 58,712 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 58,703 Class IIa (99.9%)
- 9 Class I (<0.1%)
Registered in EUDAMED under MDD with this code: 3,701 of 3,777 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 3,701 Class IIa (97.9%)
- 74 Class I (1.9%)
- 2 Class III (<0.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12110180Instruments for Dental Treatment Units - Hardware AccessoriesMDR 2 classes · n=871MDD 95.0% Class IIa · n=100terminalRegistered in EUDAMED under MDR with this code, the 871 devices are split across classes (as of 8 Sep 2026).
- 533 Class I (61.1%)
- 338 Class IIa (38.8%)
Registered in EUDAMED under MDD with this code: 95 of 100 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 95 Class IIa (95.0%)
- 5 Class I (5.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12110182Instruments for Dental Treatment Units - Software AccessoriesterminalZ12110185Instruments for Dental Treatment Units - ConsumablesterminalZ12110192Instruments for Dental Treatment Units - Medical Device SoftwareterminalZ12110199Instruments for Dental Treatment Units - OtherMDR 2 classes · n=709MDD 2 classes · n=25terminalRegistered in EUDAMED under MDR with this code, the 709 devices are split across classes (as of 8 Sep 2026).
- 361 Class IIa (50.9%)
- 348 Class I (49.0%)
Registered in EUDAMED under MDD with this code, the 25 devices are split across classes (as of 8 Sep 2026).
- 20 Class IIa (80.0%)
- 5 Class I (20.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z121190Various Dental Stomatology InstrumentsRegistered in EUDAMED under MDR with this code: 119 of 125 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 119 Class IIa (95.2%)
- 6 Class I (4.8%)
Registered in EUDAMED under MDD with this code: 108 of 108 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 108 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code: 27 of 27 devices carry Class I on their registration (as of 8 Sep 2026).
- 27 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 111 of 111 devices carry Class I on their registration (as of 8 Sep 2026).
- 111 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12119004Equipment for Diagnosis of Periodontal DiseasesterminalZ12119005Pulp Vitality AnalysersterminalRegistered in EUDAMED under MDR with this code, the 182 devices are split across classes (as of 8 Sep 2026).
- 127 Class IIa (69.7%)
- 55 Class I (30.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 30 devices are split across classes (as of 8 Sep 2026).
- 27 Class IIa (90.0%)
- 3 Class I (10.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12119008Endodontic CompactorsterminalZ12119009Apex LocatorsterminalRegistered in EUDAMED under MDR with this code, the 84 devices are split across classes (as of 8 Sep 2026).
- 55 Class I (65.4%)
- 29 Class IIa (34.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12119082Various Dental Stomatology Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 62 of 64 devices carry Class I on their registration (as of 8 Sep 2026).
- 62 Class I (96.8%)
- 2 Class IIa (3.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12119092Various Dental Stomatology Instruments - Medical Device SoftwareterminalZ12119099Various Dental Stomatology Instruments - OtherMDR 2 classes · n=915MDD 100.0% Class IIa · n=27terminalRegistered in EUDAMED under MDR with this code, the 915 devices are split across classes (as of 8 Sep 2026).
- 620 Class I (67.7%)
- 295 Class IIa (32.2%)
Registered in EUDAMED under MDD with this code: 27 of 27 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 27 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1212Ophthalmology InstrumentsZ121201Ophtalmology Assessments and Diagnosis InstrumentsZ12120101Laser Polarimetry EquipmentterminalRegistered in EUDAMED under MDR with this code, the 25 devices are split across classes (as of 8 Sep 2026).
- 23 Class IIa (92.0%)
- 2 Class IIb (8.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12120103ElectroretinographsterminalZ12120104ExophthalmometersterminalZ12120105FluoroangiographsterminalZ12120106FluorophotometersterminalZ12120107PhotocheratoscopesterminalRegistered in EUDAMED under MDR with this code: 411 of 415 devices carry Class I on their registration (as of 8 Sep 2026).
- 411 Class I (99.0%)
- 4 Class IIa (0.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12120109Retinoscopy LampsterminalZ12120110Corneal Confocal MicroscopesterminalZ12120111Eye Movement MonitorsterminalZ12120112Glasses for NystagmusterminalRegistered in EUDAMED under MDR with this code, the 20 devices are split across classes (as of 8 Sep 2026).
- 14 Class I (70.0%)
- 6 Class IIa (30.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 492 of 495 devices carry Class I on their registration (as of 8 Sep 2026).
- 492 Class I (99.3%)
- 3 Class IIa (0.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 59 devices are split across classes (as of 8 Sep 2026).
- 43 Class I (72.8%)
- 16 Class IIa (27.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12120116PachymetersterminalZ12120117Intra-Ocular Pressure RegulatorsterminalRegistered in EUDAMED under MDR with this code: 47 of 47 devices carry Class I on their registration (as of 8 Sep 2026).
- 47 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 157 of 158 devices carry Class I on their registration (as of 8 Sep 2026).
- 157 Class I (99.3%)
- 1 Class IIa (0.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12120120Instruments for the Assessment of Visual FunctionalityRegistered in EUDAMED under MDR with this code, the 172 devices are split across classes (as of 8 Sep 2026).
- 148 Class I (86.0%)
- 24 Class IIa (13.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1212012002AdaptometersterminalRegistered in EUDAMED under MDR with this code, the 28 devices are split across classes (as of 8 Sep 2026).
- 19 Class I (67.8%)
- 9 Class IIa (32.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1212012004Hess ScreensterminalZ1212012005AnomaloscopesterminalZ1212012080Instruments for the Assessment of Visual Functionality - Hardware AccessoriesMDR 99.2% Class I · n=141terminalRegistered in EUDAMED under MDR with this code: 140 of 141 devices carry Class I on their registration (as of 8 Sep 2026).
- 140 Class I (99.2%)
- 1 Class IIa (0.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1212012082Instruments for the Assessment of Visual Functionality - Software AccessoriesterminalZ1212012085Instruments for the Assessment of Visual Functionality - ConsumablesterminalZ1212012092Instruments for the Assessment of Visual Functionality - Medical Device SoftwareterminalZ1212012099Instruments for the Assessment of Visual Functionality - OtherMDR 100.0% Class I · n=830terminalRegistered in EUDAMED under MDR with this code: 830 of 830 devices carry Class I on their registration (as of 8 Sep 2026).
- 830 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 64 devices are split across classes (as of 8 Sep 2026).
- 60 Class IIa (93.7%)
- 4 Class I (6.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 70 devices are split across classes (as of 8 Sep 2026).
- 50 Class IIa (71.4%)
- 20 Class I (28.5%)
Registered in EUDAMED under MDD with this code, the 59 devices are split across classes (as of 8 Sep 2026).
- 37 Class IIa (62.7%)
- 22 Class I (37.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 28 devices are split across classes (as of 8 Sep 2026).
- 25 Class IIa (89.2%)
- 3 Class I (10.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 39 devices are split across classes (as of 8 Sep 2026).
- 23 Class IIa (58.9%)
- 16 Class I (41.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12120125PupillometersterminalZ12120180Ophtalmology Assessments and Diagnosis Instruments - Hardware AccessoriesMDR 99.5% Class I · n=234MDD 100.0% Class I · n=44terminalRegistered in EUDAMED under MDR with this code: 233 of 234 devices carry Class I on their registration (as of 8 Sep 2026).
- 233 Class I (99.5%)
- 1 Class IIa (0.4%)
Registered in EUDAMED under MDD with this code: 44 of 44 devices carry Class I on their registration (as of 8 Sep 2026).
- 44 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12120182Ophtalmology Assessments and Diagnosis Instruments - Software AccessoriesterminalZ12120185Ophtalmology Assessments and Diagnosis Instruments - ConsumablesterminalZ12120192Ophtalmology Assessments and Diagnosis Instruments - Medical Device SoftwareMDR 3 classes · n=31terminalRegistered in EUDAMED under MDR with this code, the 31 devices are split across classes (as of 8 Sep 2026).
- 22 Class IIa (70.9%)
- 5 Class IIb (16.1%)
- 4 Class I (12.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12120199Ophtalmology Assessments and Diagnosis Instruments – OtherMDR 2 classes · n=432MDD 3 classes · n=27terminalRegistered in EUDAMED under MDR with this code, the 432 devices are split across classes (as of 8 Sep 2026).
- 359 Class I (83.1%)
- 73 Class IIa (16.8%)
Registered in EUDAMED under MDD with this code, the 27 devices are split across classes (as of 8 Sep 2026).
- 15 Class IIa (55.5%)
- 7 Class IIb (25.9%)
- 5 Class I (18.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z121202Therapeutic and Surgical Ophtholmological Treatments InstrumentsZ12120201Cross–eye Convergence TrainersterminalZ12120202Laser PhotocoagulatorsterminalZ12120203Corneal MillerterminalZ12120204SynoptiscopesterminalZ12120205Instruments for Microkeratome SurgeryZ1212020501Microkeratome LasersterminalZ1212020502Microblade MicrokeratomesterminalZ1212020580Microkeratomy Instruments - Hardware AccessoriesterminalZ1212020582Microkeratomy Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDD with this code: 105 of 107 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 105 Class IIa (98.1%)
- 2 Class I (1.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1212020592Microkeratomy Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDD with this code: 42 of 42 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 42 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12120206Ophthalmic Electrosurgery InstrumentsZ1212020601Ophthalmic Electrosurgery EquipmentterminalZ1212020602Ophthalmic Microdiathermy CoagulatorsterminalZ1212020680Ophthalmic Electrosurgery Instruments - Hardware AccessoriesterminalZ1212020682Ophthalmic Electrosurgery Instruments - Software AccessoriesterminalZ1212020685Ophthalmic Electrosurgery Instruments - ConsumablesterminalZ1212020692Ophthalmic Electrosurgery Instruments - Medical Device SoftwareterminalZ1212020699Ophthalmic Electrosurgery Instruments – Otherterminal
Z12120207Phaco-Vitrectomy InstrumentsZ1212020701Phaco-EmulsifiersterminalRegistered in EUDAMED under MDD with this code: 22 of 22 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 22 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1212020703VitrectomesterminalRegistered in EUDAMED under MDR with this code, the 21 devices are split across classes (as of 8 Sep 2026).
- 18 Class IIb (85.7%)
- 2 Class I (9.5%)
- 1 Class IIa (4.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1212020782Phaco-Vitrectomy Instruments - Software AccessoriesterminalZ1212020785Phaco-Vitrectomy Instruments - ConsumablesMDR 3 classes · n=248MDD 96.0% Class IIa · n=410terminalRegistered in EUDAMED under MDR with this code, the 248 devices are split across classes (as of 8 Sep 2026).
- 140 Class IIa (56.4%)
- 102 Class IIb (41.1%)
- 6 Class I (2.4%)
Registered in EUDAMED under MDD with this code: 394 of 410 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 394 Class IIa (96.0%)
- 11 Class I (2.6%)
- 5 Class IIb (1.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1212020792Phaco-Vitrectomy Instruments - Medical Device SoftwareterminalZ1212020799Phaco-Vitrectomy Instruments - Otherterminal
Registered in EUDAMED under MDR with this code: 42 of 42 devices carry Class I on their registration (as of 8 Sep 2026).
- 42 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12120280Therapeutic and Surgical Ophtholmological Treatments Instruments - Hardware AccessoriesMDR 2 classes · n=26terminalRegistered in EUDAMED under MDR with this code, the 26 devices are split across classes (as of 8 Sep 2026).
- 24 Class I (92.3%)
- 2 Class IIb (7.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12120282Therapeutic and Surgical Ophtholmological Treatments Instruments - Software AccessoriesterminalZ12120285Therapeutic and Surgical Ophtholmological Treatments Instruments - ConsumablesMDR 2 classes · n=55terminalRegistered in EUDAMED under MDR with this code, the 55 devices are split across classes (as of 8 Sep 2026).
- 38 Class IIa (69.0%)
- 17 Class IIb (30.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12120292Therapeutic and Surgical Ophtholmological Treatments Instruments - Medical Device SoftwareterminalZ12120299Therapeutic and Surgical Ophtholmological Treatments Instruments - OtherMDR 3 classes · n=149MDD 3 classes · n=23terminalRegistered in EUDAMED under MDR with this code, the 149 devices are split across classes (as of 8 Sep 2026).
- 120 Class I (80.5%)
- 23 Class IIa (15.4%)
- 6 Class IIb (4.0%)
Registered in EUDAMED under MDD with this code, the 23 devices are split across classes (as of 8 Sep 2026).
- 15 Class IIa (65.2%)
- 4 Class I (17.3%)
- 4 Class IIb (17.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z121290Various Ophtalmology InstrumentsRegistered in EUDAMED under MDR with this code: 212 of 212 devices carry Class I on their registration (as of 8 Sep 2026).
- 212 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12129080Various Ophtalmology Instruments - Hardware AccessoriesterminalZ12129082Various Ophtalmology Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDD with this code: 33 of 33 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 33 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12129092Various Ophtalmology Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 51 devices are split across classes (as of 8 Sep 2026).
- 43 Class I (84.3%)
- 8 Class IIa (15.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1213Orthopaedic InstrumentsRegistered in EUDAMED under MDD with this code: 56 of 58 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 56 Class IIa (96.5%)
- 2 Class IIb (3.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z121302Orthopaedic Traction InstrumentsZ12130201Traction BedsterminalRegistered in EUDAMED under MDR with this code: 89 of 92 devices carry Class I on their registration (as of 8 Sep 2026).
- 89 Class I (96.7%)
- 3 Class IIa (3.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 73 of 73 devices carry Class I on their registration (as of 8 Sep 2026).
- 73 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12130282Orthopaedic Traction Instruments – Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 45 of 45 devices carry Class I on their registration (as of 8 Sep 2026).
- 45 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12130292Orthopaedic Traction Instruments - Medical Device Softwareterminal
Z121303Bone Growth Stimulation InstrumentsZ12130301Bone Growth StimulatorsterminalZ12130380Bone Growth Stimulation Instruments - Hardware AccessoriesterminalZ12130382Bone Growth Stimulation Instruments - Software AccessoriesterminalZ12130385Bone Growth Stimulation Instruments - ConsumablesterminalZ12130392Bone Growth Stimulation Instruments - Medical Device Softwareterminal
Z121304Stereotactic Orthopaedic Surgery InstrumentsRegistered in EUDAMED under MDR with this code, the 69 devices are split across classes (as of 8 Sep 2026).
- 55 Class IIb (79.7%)
- 12 Class I (17.3%)
- 2 Class IIa (2.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12130480Stereotactic Orthopaedic Surgery Instruments - Hardware AccessoriesMDR 3 classes · n=375terminalRegistered in EUDAMED under MDR with this code, the 375 devices are split across classes (as of 8 Sep 2026).
- 241 Class IIa (64.2%)
- 92 Class I (24.5%)
- 42 Class IIb (11.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12130482Stereotactic Orthopaedic Surgery Instruments - Software AccessoriesMDR 100.0% Class IIa · n=21terminalRegistered in EUDAMED under MDR with this code: 21 of 21 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 21 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 26 devices are split across classes (as of 8 Sep 2026).
- 22 Class IIa (84.6%)
- 4 Class IIb (15.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12130492Stereotactic Orthopaedic Surgery Instruments - Medical Device Softwareterminal
Z121305Motorised Orthopaedic Surgery System InstrumentsZ12130501Motorised Orthopaedic Surgery SystemsMDR 100.0% Class IIa · n=22MDD 100.0% Class IIa · n=68terminalRegistered in EUDAMED under MDR with this code: 22 of 22 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 22 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code: 68 of 68 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 68 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 176 devices are split across classes (as of 8 Sep 2026).
- 145 Class IIa (82.3%)
- 31 Class I (17.6%)
Registered in EUDAMED under MDD with this code: 599 of 601 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 599 Class IIa (99.6%)
- 2 Class I (0.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 2,338 devices are split across classes (as of 8 Sep 2026).
- 1,746 Class IIa (74.6%)
- 592 Class I (25.3%)
Registered in EUDAMED under MDD with this code, the 470 devices are split across classes (as of 8 Sep 2026).
- 356 Class IIa (75.7%)
- 114 Class I (24.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12130580Motorised Orthopaedic Surgery System Instruments - Hardware AccessoriesMDR 3 classes · n=1,352MDD 98.1% Class IIa · n=110terminalRegistered in EUDAMED under MDR with this code, the 1,352 devices are split across classes (as of 8 Sep 2026).
- 1,178 Class IIa (87.1%)
- 168 Class I (12.4%)
- 6 Class III (0.4%)
Registered in EUDAMED under MDD with this code: 108 of 110 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 108 Class IIa (98.1%)
- 1 Class I (0.9%)
- 1 Class III (0.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12130582Motorised Orthopaedic Surgery System Instruments - Software AccessoriesterminalZ12130585Motorised Orthopaedic Surgery System Instruments - ConsumablesMDR 98.5% Class IIa · n=346MDD 100.0% Class IIa · n=600terminalRegistered in EUDAMED under MDR with this code: 341 of 346 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 341 Class IIa (98.5%)
- 5 Class I (1.4%)
Registered in EUDAMED under MDD with this code: 600 of 600 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 600 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12130592Motorised Orthopaedic Surgery System Instruments - Medical Device SoftwareterminalZ12130599Motorised Orthopaedic Surgery System Instruments - OtherMDR 2 classes · n=474MDD 100.0% Class IIa · n=43terminalRegistered in EUDAMED under MDR with this code, the 474 devices are split across classes (as of 8 Sep 2026).
- 443 Class IIa (93.4%)
- 31 Class I (6.5%)
Registered in EUDAMED under MDD with this code: 43 of 43 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 43 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z121390Various Orthopaedic and Traumatology InstrumentsRegistered in EUDAMED under MDR with this code, the 67 devices are split across classes (as of 8 Sep 2026).
- 28 Class I (41.7%)
- 21 Class IIb (31.3%)
- 18 Class IIa (26.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 37 devices are split across classes (as of 8 Sep 2026).
- 31 Class IIa (83.7%)
- 6 Class IIb (16.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12139003Podoscope SystemsterminalRegistered in EUDAMED under MDR with this code, the 49 devices are split across classes (as of 8 Sep 2026).
- 45 Class I (91.8%)
- 4 Class IIa (8.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 161 of 161 devices carry Class I on their registration (as of 8 Sep 2026).
- 161 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 388 of 392 devices carry Class I on their registration (as of 8 Sep 2026).
- 388 Class I (98.9%)
- 2 Class IIa (0.5%)
- 2 Class IIb (0.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12139080Various Orthopaedic and Traumatology Instruments - Hardware AccessoriesMDR 2 classes · n=77terminalRegistered in EUDAMED under MDR with this code, the 77 devices are split across classes (as of 8 Sep 2026).
- 65 Class I (84.4%)
- 12 Class IIa (15.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12139082Various Orthopaedic and Traumatology Instruments - Software AccessoriesterminalZ12139085Various Orthopaedic and Traumatology Instruments - ConsumablesMDR 98.5% Class IIa · n=67terminalRegistered in EUDAMED under MDR with this code: 66 of 67 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 66 Class IIa (98.5%)
- 1 Class I (1.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12139092Various Orthopaedic and Traumatology Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 1,957 devices are split across classes (as of 8 Sep 2026).
- 1,538 Class IIa (78.5%)
- 418 Class I (21.3%)
- 1 Class IIb (<0.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1214ENT InstrumentsRegistered in EUDAMED under MDR with this code, the 211 devices are split across classes (as of 8 Sep 2026).
- 191 Class IIa (90.5%)
- 20 Class I (9.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 31 devices are split across classes (as of 8 Sep 2026).
- 24 Class I (77.4%)
- 7 Class IIa (22.5%)
Registered in EUDAMED under MDD with this code: 28 of 28 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 28 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z121403Evoked Potential Audiometry InstrumentsZ12140301Evoked Potential Audiometry Integrated SystemsterminalZ12140302Evoked Potential Audiometry EquipmentsterminalZ12140380Evoked Potential Audiometry Instruments - Hardware AccessoriesMDR 100.0% Class I · n=29terminalRegistered in EUDAMED under MDR with this code: 29 of 29 devices carry Class I on their registration (as of 8 Sep 2026).
- 29 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12140382Evoked Potential Audiometry Instruments - Software AccessoriesterminalZ12140385Evoked Potential Audiometry Instruments - ConsumablesterminalZ12140392Evoked Potential Audiometry Instruments - Medical Device Softwareterminal
Z121404Vestibular System Analysis InstrumentsRegistered in EUDAMED under MDR with this code, the 34 devices are split across classes (as of 8 Sep 2026).
- 20 Class I (58.8%)
- 14 Class IIa (41.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12140402Vestibular Assessment Stabilometric PlatformsterminalZ12140403Rotating Pendular ChairsterminalZ12140404Posturography SystemsterminalZ12140480Vestibular System Analysis Instruments - Hardware AccessoriesterminalZ12140482Vestibular System Analysis Instruments - Software AccessoriesterminalZ12140485Vestibular System Analysis Instruments - ConsumablesterminalZ12140492Vestibular System Analysis Instruments - Medical Device Softwareterminal
Z121405Stereotactic ENT Surgery InstrumentsZ12140501Stereotactic ENT Surgery SystemsterminalZ12140580Stereotactic ENT Surgery Instruments - Hardware AccessoriesterminalZ12140582Stereotactic ENT Surgery Instruments - Software AccessoriesterminalZ12140585Stereotactic ENT Surgery Instruments - ConsumablesterminalZ12140592Stereotactic ENT Surgery Instruments - Medical Device Softwareterminal
Z121490Various ENT InstrumentsZ12149001Otoacoustic Emissions EquipmentterminalRegistered in EUDAMED under MDR with this code: 189 of 189 devices carry Class I on their registration (as of 8 Sep 2026).
- 189 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12149003OlfactometersterminalZ12149004Oto-Caloric StimulatorsterminalRegistered in EUDAMED under MDR with this code, the 102 devices are split across classes (as of 8 Sep 2026).
- 84 Class IIa (82.3%)
- 18 Class I (17.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 262 of 262 devices carry Class I on their registration (as of 8 Sep 2026).
- 262 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12149007Otological DrillsterminalZ12149008RhinoanemometersterminalZ12149009RhinometersterminalZ12149010Voice DisplaysterminalZ12149011Electric Pharyngeal StimulatorsterminalRegistered in EUDAMED under MDR with this code, the 99 devices are split across classes (as of 8 Sep 2026).
- 87 Class I (87.8%)
- 12 Class IIa (12.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12149082Various ENT Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 301 of 301 devices carry Class I on their registration (as of 8 Sep 2026).
- 301 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12149092Various ENT Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code, the 49 devices are split across classes (as of 8 Sep 2026).
- 41 Class I (83.6%)
- 8 Class IIa (16.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1215Pneumonology and Respiratory Physiopathology InstrumentsZ121501Spirometry InstrumentsZ12150101Clinical/Diagnostic SpirometersMDR 100.0% Class IIa · n=85MDD 96.5% Class IIa · n=29terminalRegistered in EUDAMED under MDR with this code: 85 of 85 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 85 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code: 28 of 29 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 28 Class IIa (96.5%)
- 1 Class I (3.4%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 82 devices are split across classes (as of 8 Sep 2026).
- 51 Class IIa (62.1%)
- 31 Class I (37.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 40 devices are split across classes (as of 8 Sep 2026).
- 21 Class I (52.5%)
- 19 Class IIa (47.5%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12150182Spirometry Instruments - Software AccessoriesterminalZ12150185Spirometry Instruments - ConsumablesMDR 3 classes · n=178MDD 100.0% Class IIa · n=36terminalRegistered in EUDAMED under MDR with this code, the 178 devices are split across classes (as of 8 Sep 2026).
- 72 Class IIb (40.4%)
- 61 Class I (34.2%)
- 45 Class IIa (25.2%)
Registered in EUDAMED under MDD with this code: 36 of 36 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 36 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12150192Spirometry Instruments - Medical Device SoftwareterminalRegistered in EUDAMED under MDR with this code: 44 of 44 devices carry Class I on their registration (as of 8 Sep 2026).
- 44 Class I (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z121502Spirometric Telemetry InstrumentsZ12150201Complete Spirometric Telemetry SystemsterminalZ12150202Spirometric Telemetry ReceiversterminalZ12150203Spirometric Telemetry TransmittersterminalZ12150280Spirometric Telemetry Instruments - Hardware AccessoriesterminalZ12150282Spirometric Telemetry Instruments - Software AccessoriesterminalZ12150285Spirometric Telemetry Instruments - ConsumablesterminalZ12150292Spirometric Telemetry Instruments - Medical Device Softwareterminal
Z121590Various Pneumology and Respiratory Physiopathology InstrumentsZ12159001Nitrogen AnalysersterminalRegistered in EUDAMED under MDR with this code, the 237 devices are split across classes (as of 8 Sep 2026).
- 218 Class IIa (91.9%)
- 19 Class I (8.0%)
Registered in EUDAMED under MDD with this code: 35 of 36 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 35 Class IIa (97.2%)
- 1 Class IIb (2.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12159003Diffusion Analysis EquipmentterminalRegistered in EUDAMED under MDR with this code, the 229 devices are split across classes (as of 8 Sep 2026).
- 182 Class IIb (79.4%)
- 32 Class IIa (13.9%)
- 15 Class I (6.5%)
Registered in EUDAMED under MDD with this code, the 159 devices are split across classes (as of 8 Sep 2026).
- 91 Class IIb (57.2%)
- 67 Class IIa (42.1%)
- 1 Class I (0.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z12159005Bronchostimulation DosimetersterminalZ12159006Expirated Gas AnalysersterminalRegistered in EUDAMED under MDR with this code, the 51 devices are split across classes (as of 8 Sep 2026).
- 46 Class IIa (90.1%)
- 5 Class I (9.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12159008PneumotachographsterminalRegistered in EUDAMED under MDR with this code, the 133 devices are split across classes (as of 8 Sep 2026).
- 110 Class IIa (82.7%)
- 18 Class I (13.5%)
- 5 Class IIb (3.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12159010RhinomanometersterminalZ12159011Pneumological Navigation SystemterminalZ12159080Various Pneumology and Respiratory Physiopathology Instruments - Hardware AccessoriesMDR 2 classes · n=51terminalRegistered in EUDAMED under MDR with this code, the 51 devices are split across classes (as of 8 Sep 2026).
- 42 Class I (82.3%)
- 9 Class IIa (17.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12159082Various Pneumology and Respiratory Physiopathology Instruments - Software AccessoriesterminalZ12159085Various Pneumology and Respiratory Physiopathology Instruments - ConsumablesMDR 96.6% Class I · n=120terminalRegistered in EUDAMED under MDR with this code: 116 of 120 devices carry Class I on their registration (as of 8 Sep 2026).
- 116 Class I (96.6%)
- 4 Class IIa (3.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12159092Various Pneumology and Respiratory Physiopathology Instruments - Medical Device SoftwareterminalZ12159099Various Pneumology and Respiratory Physiopathology Instruments - OtherMDR 99.1% Class IIa · n=1,062MDD 3 classes · n=128terminalRegistered in EUDAMED under MDR with this code: 1,053 of 1,062 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 1,053 Class IIa (99.1%)
- 6 Class I (0.5%)
- 3 Class IIb (0.2%)
Registered in EUDAMED under MDD with this code, the 128 devices are split across classes (as of 8 Sep 2026).
- 109 Class IIb (85.1%)
- 18 Class IIa (14.0%)
- 1 Class I (0.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z1216Urology InstrumentsZ121601Extracorporeal Lithotripsy InstrumentsRegistered in EUDAMED under MDR with this code, the 24 devices are split across classes (as of 8 Sep 2026).
- 22 Class IIb (91.6%)
- 1 Class I (4.1%)
- 1 Class IIa (4.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12160180Extracorporeal Lithotripsy Instruments - Hardware AccessoriesterminalZ12160182Extracorporeal Lithotripsy Instruments - Software AccessoriesterminalZ12160185Extracorporeal Lithotripsy Instruments - ConsumablesterminalZ12160192Extracorporeal Lithotripsy Instruments - Medical Device Softwareterminal
Z121602Holter System Instruments for Urodynamic ParametersZ12160201Urodynamic Holter AnalysersterminalZ12160202Urodynamic Holter RecordersterminalZ12160280Holter System Instruments for Urodynamic Parameters - Hardware AccessoriesterminalZ12160282Holter System Instruments for Urodynamic Parameters - Software AccessoriesterminalZ12160285Holter System Instruments for Urodynamic Parameters - ConsumablesterminalZ12160292Holter System Instruments for Urodynamic Parameters - Medical Device Softwareterminal
Z121603Prostate Thermotherapy InstrumentsZ12160301Equipment for Microwave Prostate ThermotherapyterminalZ12160302Equipment for Liquid Prostate ThermotherapyterminalZ12160303Equipment for Ultrasonic Oncology TherapyterminalZ12160380Prostate Thermotherapy Instruments - Hardware AccessoriesterminalZ12160382Prostate Thermotherapy Instruments - Software AccessoriesterminalZ12160385Prostate Thermotherapy Instruments - ConsumablesterminalZ12160392Prostate Thermotherapy Instruments - Medical Device SoftwareterminalZ12160399Prostate Thermotherapy Instruments - Otherterminal
Z121604Urodynamics InstrumentsZ12160401Urodynamics SystemsterminalZ12160480Urodynamics Instruments - Hardware AccessoriesterminalZ12160482Urodynamics Instruments - Software AccessoriesterminalRegistered in EUDAMED under MDR with this code: 52 of 52 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 52 Class IIa (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z12160492Urodynamics Instruments - Medical Device Softwareterminal
Registered in EUDAMED under MDR with this code, the 25 devices are split across classes (as of 8 Sep 2026).
- 17 Class IIa (68.0%)
- 8 Class I (32.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z121690Various Instruments for UrologyZ12169001Penile Tumescence Measuring EquipmentterminalZ12169002Urological StimulatorsterminalZ12169003Ejaculation StimulatorsterminalZ12169004Erectile Dysfunction StimulatorsterminalZ12169080Various Instruments for Urology - Hardware AccessoriesterminalZ12169082Various Instruments for Urology - Software AccessoriesterminalZ12169085Various Instruments for Urology - ConsumablesterminalZ12169092Various Instruments for Urology - Medical Device SoftwareterminalZ12169099Various Instruments for Urology - Otherterminal
Z1217Blood Transfusion InstrumentsRegistered in EUDAMED under MDR with this code, the 103 devices are split across classes (as of 8 Sep 2026).
- 97 Class IIa (94.1%)
- 6 Class I (5.8%)
Registered in EUDAMED under MDD with this code: 22 of 23 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 22 Class IIa (95.6%)
- 1 Class I (4.3%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z121702Blood and Blood Components FreezersMDR 100.0% Class IIa · n=223MDD 98.3% Class IIa · n=59terminalRegistered in EUDAMED under MDR with this code: 223 of 223 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 223 Class IIa (100.0%)
Registered in EUDAMED under MDD with this code: 58 of 59 devices carry Class IIa on their registration (as of 8 Sep 2026).
- 58 Class IIa (98.3%)
- 1 Class III (1.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z121703Blood and Blood Components ThawersterminalZ121704Apheresis EquipmentZ12170401Blood Donation Apheresis EquipmentterminalRegistered in EUDAMED under MDR with this code: 38 of 38 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 38 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z121780Blood Transfusion Instruments - Hardware AccessoriesterminalRegistered in EUDAMED under MDR with this code, the 68 devices are split across classes (as of 8 Sep 2026).
- 36 Class I (52.9%)
- 26 Class IIa (38.2%)
- 6 Class IIb (8.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z1290Various Instruments for Functional Exploration and Therapeutic InterventionsRegistered in EUDAMED under MDR with this code, the 38 devices are split across classes (as of 8 Sep 2026).
- 25 Class I (65.7%)
- 13 Class IIa (34.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code: 1,197 of 1,198 devices carry Class I on their registration (as of 8 Sep 2026).
- 1,197 Class I (99.9%)
- 1 Class IIa (<0.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z129005Generic PhotostimulatorsterminalZ129006Treadmills for Physiotherapy and/or Diagnostic UsesMDR 3 classes · n=425MDD 100.0% Class IIb · n=72terminalRegistered in EUDAMED under MDR with this code, the 425 devices are split across classes (as of 8 Sep 2026).
- 340 Class IIa (80.0%)
- 77 Class I (18.1%)
- 8 Class IIb (1.8%)
Registered in EUDAMED under MDD with this code: 72 of 72 devices carry Class IIb on their registration (as of 8 Sep 2026).
- 72 Class IIb (100.0%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Registered in EUDAMED under MDR with this code, the 222 devices are split across classes (as of 8 Sep 2026).
- 94 Class I (42.3%)
- 92 Class IIb (41.4%)
- 36 Class IIa (16.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z129009Equipment for Analysing PotentialterminalZ129010Multi-Disciplinary Holter SystemsterminalZ129011Multi-Disciplinary Telemetry SystemsterminalRegistered in EUDAMED under MDR with this code, the 37 devices are split across classes (as of 8 Sep 2026).
- 26 Class IIa (70.2%)
- 11 Class I (29.7%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 172 devices are split across classes (as of 8 Sep 2026).
- 97 Class I (56.3%)
- 75 Class IIa (43.6%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Registered in EUDAMED under MDR with this code, the 333 devices are split across classes (as of 8 Sep 2026).
- 250 Class IIb (75.0%)
- 50 Class I (15.0%)
- 33 Class IIa (9.9%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z129080Various Instruments for Functional Exploration and Therapeutic Interventions - Hardware AccessoriesMDR 95.7% Class I · n=95terminalRegistered in EUDAMED under MDR with this code: 91 of 95 devices carry Class I on their registration (as of 8 Sep 2026).
- 91 Class I (95.7%)
- 4 Class IIa (4.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z129082Various Instruments for Functional Exploration and Therapeutic Interventions - Software AccessoriesMDR 3 classes · n=21terminalRegistered in EUDAMED under MDR with this code, the 21 devices are split across classes (as of 8 Sep 2026).
- 12 Class I (57.1%)
- 6 Class IIa (28.5%)
- 3 Class IIb (14.2%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
Z129085Various Instruments for Functional Exploration and Therapeutic Interventions - Specific MaterialsterminalZ129092Various Instruments for Functional Exploration and Therapeutic Interventions - Medical Device SoftwareMDR 3 classes · n=63MDD 2 classes · n=24terminalRegistered in EUDAMED under MDR with this code, the 63 devices are split across classes (as of 8 Sep 2026).
- 46 Class IIa (73.0%)
- 13 Class I (20.6%)
- 4 Class IIb (6.3%)
Registered in EUDAMED under MDD with this code, the 24 devices are split across classes (as of 8 Sep 2026).
- 13 Class IIa (54.1%)
- 11 Class I (45.8%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination. MDD and IVDD classes are the directive classification and can differ under MDR or IVDR.
Z129099Various Instruments for Functional Exploration and Therapeutic Interventions - OtherMDR 4 classes · n=889terminalRegistered in EUDAMED under MDR with this code, the 889 devices are split across classes (as of 8 Sep 2026).
- 707 Class IIa (79.5%)
- 179 Class I (20.1%)
- 2 Class IIb (0.2%)
- 1 Class III (0.1%)
Counted once per primary UDI-DI, using the class on the registration. The class of a device comes from the MDR and IVDR classification rules for its intended purpose, so a code is evidence of how others registered, not a determination.
How Z12 is structured
The Instruments for Functional Explorations and Therapeutic Interventions branch runs 5 levels deep. 129 entries below are branch headings that group other codes rather than naming a device, so a classification has to resolve all the way down to one of the 994 codes marked terminal.
75 terminal codes are “- Other” entries and 101 are “- Accessories” entries, 18% of the branch. An “- Other” code is the residual slot for devices its siblings do not name, so it is worth ruling out every specific sibling before settling on one.
The largest sub-branch is Z1202 (Endoscopic and Minimally Invasive Surgery Instruments), holding 155 of the 994 terminal codes.
Frequently asked questions
- Which Z12 codes can be used in a EUDAMED device record?
- 994 of the 1,123 codes listed under Z12 (Instruments for Functional Explorations and Therapeutic Interventions) are terminal and can be selected. The other 129 are branch headings that cannot.
- How deep is the Z12 hierarchy?
- The Z12 branch runs 5 levels below the group code. Its largest sub-branch is Z1202 (Endoscopic and Minimally Invasive Surgery Instruments), which holds 155 of the 994 terminal codes.
- How many Z12 codes are catch-all entries?
- 75 terminal codes under Z12 are "- Other" entries and 101 are "- Accessories" entries, 18% of the branch. The remaining 818 name a specific device type.
Not sure which level to stop at, or which of two plausible codes to submit? The guide to choosing an EMDN code walks the decision level by level, with a worked example and the mistakes that get a EUDAMED registration rejected.
Classifying more than a handful of devices?
EUDAMate maps your device list against all 6,773 terminal EMDN codes with confidence-scored suggestions you review and confirm. Start with a free Readiness Check on your own data.
Run a free Readiness CheckOther groups in category Z
Source: European Commission, EMDN v2026 official release. Terminal codes are the only codes accepted in a EUDAMED device record. EMDN is a nomenclature, not a risk classification. MDR/IVDR class is determined separately.